60 GHz局部和均匀暴露条件下兔眼温度升高的数值分析

K. Sasaki, M. Kojima, K. Wake, Soichi Watanabe, Yukihisa Suzuki, A. Hirata
{"title":"60 GHz局部和均匀暴露条件下兔眼温度升高的数值分析","authors":"K. Sasaki, M. Kojima, K. Wake, Soichi Watanabe, Yukihisa Suzuki, A. Hirata","doi":"10.1145/2093698.2093795","DOIUrl":null,"url":null,"abstract":"A numerical dosimetry was performed for a rabbit ocular exposure by 60-GHz millimeter wave in this study. We compared calculated temperature elevation between localized exposure by a lens antenna and uniformed exposure by plane wave. Here, incident power density was normalized against spacial average of incident power over the surface of cornea according to the previous study. The peak incident power density of the lens antenna was 5.3 times higher than that of the plane wave. Therefore, the maximum temperature elevation by the lens antenna exposure was higher than that by the plane wave exposure. Thus, possibility was shown that threshold incident power density for ocular injury with the lens antenna exposure becomes lower than that with the plane wave exposure.","PeriodicalId":91990,"journal":{"name":"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-10-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A numerical analysis of temperature elevation in a rabbit ocular with localized and uniformed exposure conditions at 60 GHz\",\"authors\":\"K. Sasaki, M. Kojima, K. Wake, Soichi Watanabe, Yukihisa Suzuki, A. Hirata\",\"doi\":\"10.1145/2093698.2093795\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A numerical dosimetry was performed for a rabbit ocular exposure by 60-GHz millimeter wave in this study. We compared calculated temperature elevation between localized exposure by a lens antenna and uniformed exposure by plane wave. Here, incident power density was normalized against spacial average of incident power over the surface of cornea according to the previous study. The peak incident power density of the lens antenna was 5.3 times higher than that of the plane wave. Therefore, the maximum temperature elevation by the lens antenna exposure was higher than that by the plane wave exposure. Thus, possibility was shown that threshold incident power density for ocular injury with the lens antenna exposure becomes lower than that with the plane wave exposure.\",\"PeriodicalId\":91990,\"journal\":{\"name\":\"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/2093698.2093795\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"... International Symposium on Applied Sciences in Biomedical and Communication Technologies. International Symposium on Applied Sciences in Biomedical and Communication Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2093698.2093795","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本研究对60 ghz毫米波对家兔眼部照射进行了数值剂量学研究。我们比较了透镜天线局部暴露和平面波均匀暴露计算出的温度升高。在这里,根据之前的研究,将入射功率密度归一化为角膜表面入射功率的空间平均值。透镜天线的入射功率密度峰值是平面波的5.3倍。因此,透镜天线暴露的最高温度升高高于平面波暴露的最高温度升高。由此可见,晶状体天线暴露的眼损伤阈值入射功率密度可能比平面波暴露的低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A numerical analysis of temperature elevation in a rabbit ocular with localized and uniformed exposure conditions at 60 GHz
A numerical dosimetry was performed for a rabbit ocular exposure by 60-GHz millimeter wave in this study. We compared calculated temperature elevation between localized exposure by a lens antenna and uniformed exposure by plane wave. Here, incident power density was normalized against spacial average of incident power over the surface of cornea according to the previous study. The peak incident power density of the lens antenna was 5.3 times higher than that of the plane wave. Therefore, the maximum temperature elevation by the lens antenna exposure was higher than that by the plane wave exposure. Thus, possibility was shown that threshold incident power density for ocular injury with the lens antenna exposure becomes lower than that with the plane wave exposure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信