自密实混凝土塑性收缩开裂:毛细压力和休眠期的影响

IF 0.7 Q4 CONSTRUCTION & BUILDING TECHNOLOGY
F. Sayahi, M. Emborg, H. Hedlund, A. Ćwirzeń
{"title":"自密实混凝土塑性收缩开裂:毛细压力和休眠期的影响","authors":"F. Sayahi, M. Emborg, H. Hedlund, A. Ćwirzeń","doi":"10.2478/ncr-2019-0012","DOIUrl":null,"url":null,"abstract":"Abstract This research investigates the effect of capillary pressure and the length of the hydration dormant period on the plastic shrinkage cracking tendency of SCC by studying specimens produced with different w/c ratios, cement types and SP dosages. A relationship between the capillary pressure rate and the length of the hydration dormant period is defined, which can explain the cracking severity of the concrete when the volumetric deformation is unknown. The results show, that the cracking tendency of SCC was the lowest in case of w/c ratio between 0.45 and 0.55, finer and more rapid hardening cement, and lower dosage of SP. The dormant period was prolonged by increasing the w/c ratio, using coarser cement, and higher SP dosage. It was concluded that the cracking tendency of concrete is a function of the capillary pressure buildup rate and the length of the dormant period.","PeriodicalId":42762,"journal":{"name":"Nordic Concrete Research","volume":"69 1","pages":"67 - 88"},"PeriodicalIF":0.7000,"publicationDate":"2019-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Plastic Shrinkage Cracking of Self-compacting Concrete: Influence of Capillary Pressure and Dormant Period\",\"authors\":\"F. Sayahi, M. Emborg, H. Hedlund, A. Ćwirzeń\",\"doi\":\"10.2478/ncr-2019-0012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This research investigates the effect of capillary pressure and the length of the hydration dormant period on the plastic shrinkage cracking tendency of SCC by studying specimens produced with different w/c ratios, cement types and SP dosages. A relationship between the capillary pressure rate and the length of the hydration dormant period is defined, which can explain the cracking severity of the concrete when the volumetric deformation is unknown. The results show, that the cracking tendency of SCC was the lowest in case of w/c ratio between 0.45 and 0.55, finer and more rapid hardening cement, and lower dosage of SP. The dormant period was prolonged by increasing the w/c ratio, using coarser cement, and higher SP dosage. It was concluded that the cracking tendency of concrete is a function of the capillary pressure buildup rate and the length of the dormant period.\",\"PeriodicalId\":42762,\"journal\":{\"name\":\"Nordic Concrete Research\",\"volume\":\"69 1\",\"pages\":\"67 - 88\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2019-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nordic Concrete Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/ncr-2019-0012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nordic Concrete Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/ncr-2019-0012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 7

摘要

摘要通过研究不同w/c比、水泥类型和SP掺量的试样,探讨了毛细压力和水化休止期长度对细观混凝土塑性收缩开裂倾向的影响。定义了毛细压力速率与水化休眠期长度的关系,可以解释体积变形未知时混凝土的开裂严重程度。结果表明:当w/c比在0.45 ~ 0.55之间,水泥越细越快硬化,SP用量越低时,SCC的开裂倾向最低;增大w/c比,水泥越粗,SP用量越大,休眠期越长;结果表明,混凝土的开裂倾向是毛管压力积累速率和静息期长度的函数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Plastic Shrinkage Cracking of Self-compacting Concrete: Influence of Capillary Pressure and Dormant Period
Abstract This research investigates the effect of capillary pressure and the length of the hydration dormant period on the plastic shrinkage cracking tendency of SCC by studying specimens produced with different w/c ratios, cement types and SP dosages. A relationship between the capillary pressure rate and the length of the hydration dormant period is defined, which can explain the cracking severity of the concrete when the volumetric deformation is unknown. The results show, that the cracking tendency of SCC was the lowest in case of w/c ratio between 0.45 and 0.55, finer and more rapid hardening cement, and lower dosage of SP. The dormant period was prolonged by increasing the w/c ratio, using coarser cement, and higher SP dosage. It was concluded that the cracking tendency of concrete is a function of the capillary pressure buildup rate and the length of the dormant period.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Nordic Concrete Research
Nordic Concrete Research CONSTRUCTION & BUILDING TECHNOLOGY-
自引率
20.00%
发文量
8
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信