场老化交联聚乙烯电缆泄漏电流特性研究

H. Muto, Y. Yamashita, Y. Maruyuma, Z. Iwata
{"title":"场老化交联聚乙烯电缆泄漏电流特性研究","authors":"H. Muto, Y. Yamashita, Y. Maruyuma, Z. Iwata","doi":"10.1109/ICPADM.1991.172105","DOIUrl":null,"url":null,"abstract":"The leakage current characteristic of degraded XLPE (cross-linked polyethylene) cable was investigated under DC and AC electric field. The cable with heavy vented tree degradation showed a typical increase of DC leakage current and Dc component. In this instance, the bridged vented tree plays an important role in the increase of this current. The low-frequency component of the charging current was observed in the type of cable. The DC leakage current, DC component, and low-frequency component of the charging current were found to vary in a complex manner, depending on the applied voltage and its history. This may be attributable to the change of the internal water tree structure.<<ETX>>","PeriodicalId":6450,"journal":{"name":"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials","volume":"2 1","pages":"494-497 vol.1"},"PeriodicalIF":0.0000,"publicationDate":"1991-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A study on leakage current characteristics of field aged XLPE cable\",\"authors\":\"H. Muto, Y. Yamashita, Y. Maruyuma, Z. Iwata\",\"doi\":\"10.1109/ICPADM.1991.172105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The leakage current characteristic of degraded XLPE (cross-linked polyethylene) cable was investigated under DC and AC electric field. The cable with heavy vented tree degradation showed a typical increase of DC leakage current and Dc component. In this instance, the bridged vented tree plays an important role in the increase of this current. The low-frequency component of the charging current was observed in the type of cable. The DC leakage current, DC component, and low-frequency component of the charging current were found to vary in a complex manner, depending on the applied voltage and its history. This may be attributable to the change of the internal water tree structure.<<ETX>>\",\"PeriodicalId\":6450,\"journal\":{\"name\":\"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials\",\"volume\":\"2 1\",\"pages\":\"494-497 vol.1\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPADM.1991.172105\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"[1991] Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPADM.1991.172105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

研究了交联聚乙烯(XLPE)电缆在直流和交流电场作用下的泄漏电流特性。通风树退化严重的电缆直流泄漏电流和直流分量明显增加。在这种情况下,桥式通风树在增加电流方面起着重要作用。在该类型电缆中观察到充电电流的低频分量。发现充电电流的直流泄漏电流、直流分量和低频分量以复杂的方式变化,取决于施加的电压及其历史。这可能与内部水树结构的变化有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A study on leakage current characteristics of field aged XLPE cable
The leakage current characteristic of degraded XLPE (cross-linked polyethylene) cable was investigated under DC and AC electric field. The cable with heavy vented tree degradation showed a typical increase of DC leakage current and Dc component. In this instance, the bridged vented tree plays an important role in the increase of this current. The low-frequency component of the charging current was observed in the type of cable. The DC leakage current, DC component, and low-frequency component of the charging current were found to vary in a complex manner, depending on the applied voltage and its history. This may be attributable to the change of the internal water tree structure.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信