术后呼吸并发症的无线监测

A. Bates, D. Arvind, J. Mann
{"title":"术后呼吸并发症的无线监测","authors":"A. Bates, D. Arvind, J. Mann","doi":"10.1145/2077546.2077549","DOIUrl":null,"url":null,"abstract":"Respiratory complications may occur in post-operative patients but are often difficult to detect due to the lack of a well-tolerated and reliable monitoring method. We have developed a wireless accelerometer-based device that measures chest wall rotations due to breathing and has been shown to provide an accurate measure of respiratory rate in a clinical setting, when validated against rates obtained from nasal pressure. This paper describes a method for detecting instances of respiratory problems due to physical airway obstruction and central nervous system (CNS) respiratory depression using a combination of nasal pressure and chest wall rotation signals in gynaecological patients during the first night after surgery. Waxing and waning of breath amplitude and irregularity of breath length are found to be useful indicators. A clinical study involving 19 post-operative patients shows that the proposed method is able to detect and distinguish between both forms of respiratory complications.","PeriodicalId":91386,"journal":{"name":"Proceedings Wireless Health ... [electronic resource]. Wireless Health (Conference)","volume":"30 1","pages":"2"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Wireless monitoring of post-operative respiratory complications\",\"authors\":\"A. Bates, D. Arvind, J. Mann\",\"doi\":\"10.1145/2077546.2077549\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Respiratory complications may occur in post-operative patients but are often difficult to detect due to the lack of a well-tolerated and reliable monitoring method. We have developed a wireless accelerometer-based device that measures chest wall rotations due to breathing and has been shown to provide an accurate measure of respiratory rate in a clinical setting, when validated against rates obtained from nasal pressure. This paper describes a method for detecting instances of respiratory problems due to physical airway obstruction and central nervous system (CNS) respiratory depression using a combination of nasal pressure and chest wall rotation signals in gynaecological patients during the first night after surgery. Waxing and waning of breath amplitude and irregularity of breath length are found to be useful indicators. A clinical study involving 19 post-operative patients shows that the proposed method is able to detect and distinguish between both forms of respiratory complications.\",\"PeriodicalId\":91386,\"journal\":{\"name\":\"Proceedings Wireless Health ... [electronic resource]. Wireless Health (Conference)\",\"volume\":\"30 1\",\"pages\":\"2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings Wireless Health ... [electronic resource]. Wireless Health (Conference)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1145/2077546.2077549\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings Wireless Health ... [electronic resource]. Wireless Health (Conference)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1145/2077546.2077549","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

术后患者可能出现呼吸系统并发症,但由于缺乏耐受性良好和可靠的监测方法,往往难以发现。我们已经开发了一种基于无线加速度计的设备,该设备可以测量呼吸引起的胸壁旋转,并已被证明在临床环境中提供准确的呼吸速率测量,当与从鼻压力获得的速率进行验证时。本文介绍了一种方法,用于检测呼吸问题的情况下,由于物理气道阻塞和中枢神经系统(CNS)呼吸抑制使用鼻压和胸壁旋转信号的组合在手术后的第一个晚上妇科患者。呼吸振幅的起伏和呼吸长度的不规则性是有用的指标。一项涉及19例术后患者的临床研究表明,所提出的方法能够检测和区分两种形式的呼吸系统并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Wireless monitoring of post-operative respiratory complications
Respiratory complications may occur in post-operative patients but are often difficult to detect due to the lack of a well-tolerated and reliable monitoring method. We have developed a wireless accelerometer-based device that measures chest wall rotations due to breathing and has been shown to provide an accurate measure of respiratory rate in a clinical setting, when validated against rates obtained from nasal pressure. This paper describes a method for detecting instances of respiratory problems due to physical airway obstruction and central nervous system (CNS) respiratory depression using a combination of nasal pressure and chest wall rotation signals in gynaecological patients during the first night after surgery. Waxing and waning of breath amplitude and irregularity of breath length are found to be useful indicators. A clinical study involving 19 post-operative patients shows that the proposed method is able to detect and distinguish between both forms of respiratory complications.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信