流动注射分析中的自动化:氯化物和总铁的同时测定

José Y. Neira, Joaquim A. Nóbrega
{"title":"流动注射分析中的自动化:氯化物和总铁的同时测定","authors":"José Y. Neira,&nbsp;Joaquim A. Nóbrega","doi":"10.1002/(SICI)1098-2728(1999)11:5<260::AID-LRA3>3.0.CO;2-Y","DOIUrl":null,"url":null,"abstract":"<p>In this article, we describe an automated flow-injection system for simultaneous determination of Cl<sup>−</sup> and total Fe. Chloride was potentiometrically determined, and total Fe was colorimetrically determined after reduction of Fe(III) to Fe(II) and complexation with 1,10-phenanthroline. Both measurements were performed simultaneously, and the signals were continuously shown on the computer video screen. A Turbo Basic program was written to activate the peristaltic pump, valves, and to control signal acquisition and treatment. The operator only needs to inject the samples, and all the others steps are performed by the automated system. The system presented a sampling frequency of 60 h<sup>−1</sup>, that is, 120 simultaneous determinations of Cl<sup>−</sup> and total Fe. © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 260–265, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 5","pages":"260-265"},"PeriodicalIF":0.0000,"publicationDate":"1999-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:5<260::AID-LRA3>3.0.CO;2-Y","citationCount":"2","resultStr":"{\"title\":\"Automation in flow-injection analysis: Simultaneous determination of chloride and total iron\",\"authors\":\"José Y. Neira,&nbsp;Joaquim A. Nóbrega\",\"doi\":\"10.1002/(SICI)1098-2728(1999)11:5<260::AID-LRA3>3.0.CO;2-Y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>In this article, we describe an automated flow-injection system for simultaneous determination of Cl<sup>−</sup> and total Fe. Chloride was potentiometrically determined, and total Fe was colorimetrically determined after reduction of Fe(III) to Fe(II) and complexation with 1,10-phenanthroline. Both measurements were performed simultaneously, and the signals were continuously shown on the computer video screen. A Turbo Basic program was written to activate the peristaltic pump, valves, and to control signal acquisition and treatment. The operator only needs to inject the samples, and all the others steps are performed by the automated system. The system presented a sampling frequency of 60 h<sup>−1</sup>, that is, 120 simultaneous determinations of Cl<sup>−</sup> and total Fe. © 1999 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 11: 260–265, 1999</p>\",\"PeriodicalId\":100863,\"journal\":{\"name\":\"Laboratory Robotics and Automation\",\"volume\":\"11 5\",\"pages\":\"260-265\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:5<260::AID-LRA3>3.0.CO;2-Y\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laboratory Robotics and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%281999%2911%3A5%3C260%3A%3AAID-LRA3%3E3.0.CO%3B2-Y\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%281999%2911%3A5%3C260%3A%3AAID-LRA3%3E3.0.CO%3B2-Y","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

在本文中,我们描述了一个自动流动注射系统,同时测定Cl−和总铁。氯离子用电位法测定,铁(III)还原为铁(II)并与1,10-菲罗啉络合后,用比色法测定总铁。两种测量同时进行,并且信号连续地显示在计算机视频屏幕上。编写了一个Turbo Basic程序来激活蠕动泵、阀门,并控制信号的采集和处理。操作人员只需注入样品,其余步骤均由自动化系统完成。该系统的采样频率为60 h−1,即同时测定120个Cl−和总Fe。©1999 John Wiley &儿子,Inc。实验室机器人控制与自动化,1999
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automation in flow-injection analysis: Simultaneous determination of chloride and total iron

In this article, we describe an automated flow-injection system for simultaneous determination of Cl and total Fe. Chloride was potentiometrically determined, and total Fe was colorimetrically determined after reduction of Fe(III) to Fe(II) and complexation with 1,10-phenanthroline. Both measurements were performed simultaneously, and the signals were continuously shown on the computer video screen. A Turbo Basic program was written to activate the peristaltic pump, valves, and to control signal acquisition and treatment. The operator only needs to inject the samples, and all the others steps are performed by the automated system. The system presented a sampling frequency of 60 h−1, that is, 120 simultaneous determinations of Cl and total Fe. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 260–265, 1999

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信