基于磁流体磁桥的电流传感器的研制

忠津 孝, 笹田 一郎, T. Tadatsu, I. Sasada
{"title":"基于磁流体磁桥的电流传感器的研制","authors":"忠津 孝, 笹田 一郎, T. Tadatsu, I. Sasada","doi":"10.3379/MSJMAG.1104R014","DOIUrl":null,"url":null,"abstract":"Demands for dc current sensors have recently been increasing. We developed a hysteresis-free current sensor based on a magnetic bridge by using magnetic fluid as a core material, which is super-paramagnetic and has no magnetic hysteresis. In the experiment, the core size was 42 mm in outer diameter, 28 mm in inner diameter, and 3.5 mm in height. The sensor became saturated at ±200 A input current, but no hysteresis was observed throughout the whole range of measurement. In a measurement range of ±20 A, the sensitivity was 0.603 mV/A, the linearity error was ±0.7 %, and the temperature error characteristics were -0.2 %/°C from 0 °C to 30 °C. This hysteresis-free current sensor would be useful in energy-efficient power systems to enable accurate current monitoring, especially in dc power-distribution systems.","PeriodicalId":11722,"journal":{"name":"Engineering sciences reports, Kyushu University","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2010-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of a Current Sensor Based on a Magnetic Fluid Magnetic Bridge\",\"authors\":\"忠津 孝, 笹田 一郎, T. Tadatsu, I. Sasada\",\"doi\":\"10.3379/MSJMAG.1104R014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Demands for dc current sensors have recently been increasing. We developed a hysteresis-free current sensor based on a magnetic bridge by using magnetic fluid as a core material, which is super-paramagnetic and has no magnetic hysteresis. In the experiment, the core size was 42 mm in outer diameter, 28 mm in inner diameter, and 3.5 mm in height. The sensor became saturated at ±200 A input current, but no hysteresis was observed throughout the whole range of measurement. In a measurement range of ±20 A, the sensitivity was 0.603 mV/A, the linearity error was ±0.7 %, and the temperature error characteristics were -0.2 %/°C from 0 °C to 30 °C. This hysteresis-free current sensor would be useful in energy-efficient power systems to enable accurate current monitoring, especially in dc power-distribution systems.\",\"PeriodicalId\":11722,\"journal\":{\"name\":\"Engineering sciences reports, Kyushu University\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Engineering sciences reports, Kyushu University\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3379/MSJMAG.1104R014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Engineering sciences reports, Kyushu University","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3379/MSJMAG.1104R014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

近年来,对直流电流传感器的需求不断增加。本文以超顺磁性、无磁滞的磁流体为核心材料,研制了一种基于磁桥的无磁滞电流传感器。实验中,岩心尺寸为外径42 mm,内径28 mm,高3.5 mm。传感器在±200 A输入电流时饱和,但在整个测量范围内未观察到磁滞。在±20 a的测量范围内,灵敏度为0.603 mV/ a,线性误差为±0.7%,温度误差特性为- 0.2% /°C。这种无迟滞电流传感器可用于节能电力系统,以实现准确的电流监测,特别是在直流配电系统中。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a Current Sensor Based on a Magnetic Fluid Magnetic Bridge
Demands for dc current sensors have recently been increasing. We developed a hysteresis-free current sensor based on a magnetic bridge by using magnetic fluid as a core material, which is super-paramagnetic and has no magnetic hysteresis. In the experiment, the core size was 42 mm in outer diameter, 28 mm in inner diameter, and 3.5 mm in height. The sensor became saturated at ±200 A input current, but no hysteresis was observed throughout the whole range of measurement. In a measurement range of ±20 A, the sensitivity was 0.603 mV/A, the linearity error was ±0.7 %, and the temperature error characteristics were -0.2 %/°C from 0 °C to 30 °C. This hysteresis-free current sensor would be useful in energy-efficient power systems to enable accurate current monitoring, especially in dc power-distribution systems.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信