B. A. Boyko, A. Bykov, M. I. Dolotenko, N. P. Kolokolchikov, I. M. Markevtsev, O. Tatsenko, K. Shuvalov
{"title":"带着创纪录的磁场到达21世纪","authors":"B. A. Boyko, A. Bykov, M. I. Dolotenko, N. P. Kolokolchikov, I. M. Markevtsev, O. Tatsenko, K. Shuvalov","doi":"10.1109/PPC.1999.823621","DOIUrl":null,"url":null,"abstract":"Many years work on the development of magnetocumulative generators of ultra-high magnetic fields has led to the creation of the cascade MC-1 generator, in which a magnetic field of more than 28 MGs was recorded in 1998. This device consists of a generator solenoid (the first cascade) with internal and external diameters of 175 mm and 200 mm respectively and a length of 500 mm, and two internal cascades with diameters of 28/spl times/35 mm and 12/spl times/17 mm and a length of /spl sim/200 mm. One-cascade system of explosive compression, consisting of the main HE-charge with diameters of 360/spl times/650 mm, a length of 350 mm and a mass of /spl sim/170 kg, steel cylinder-impactor with an external diameter of 356 mm and a thickness of 7 mm, and internal HE-charge with diameters of 200/spl times/300 mm and a length of 280 mm, is located on the outside of the solenoid. The MC-1 generator solenoid is powered with a current of 4-5 MA. MC-1 generator operation time (without powering time and HE-charge detonation time) is about 15 /spl mu/s, maximum liner implosion velocity is more than 6 km/s, the magnetic field derivative reaches values of /spl sim/5 10/sub 13/ Gs/s. The diameter of the final field volume is 24 mm, its length is /spl sim/100 mm.","PeriodicalId":11209,"journal":{"name":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","volume":"27 1","pages":"746-749 vol.2"},"PeriodicalIF":0.0000,"publicationDate":"1999-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"With record magnetic fields to the 21st Century\",\"authors\":\"B. A. Boyko, A. Bykov, M. I. Dolotenko, N. P. Kolokolchikov, I. M. Markevtsev, O. Tatsenko, K. Shuvalov\",\"doi\":\"10.1109/PPC.1999.823621\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Many years work on the development of magnetocumulative generators of ultra-high magnetic fields has led to the creation of the cascade MC-1 generator, in which a magnetic field of more than 28 MGs was recorded in 1998. This device consists of a generator solenoid (the first cascade) with internal and external diameters of 175 mm and 200 mm respectively and a length of 500 mm, and two internal cascades with diameters of 28/spl times/35 mm and 12/spl times/17 mm and a length of /spl sim/200 mm. One-cascade system of explosive compression, consisting of the main HE-charge with diameters of 360/spl times/650 mm, a length of 350 mm and a mass of /spl sim/170 kg, steel cylinder-impactor with an external diameter of 356 mm and a thickness of 7 mm, and internal HE-charge with diameters of 200/spl times/300 mm and a length of 280 mm, is located on the outside of the solenoid. The MC-1 generator solenoid is powered with a current of 4-5 MA. MC-1 generator operation time (without powering time and HE-charge detonation time) is about 15 /spl mu/s, maximum liner implosion velocity is more than 6 km/s, the magnetic field derivative reaches values of /spl sim/5 10/sub 13/ Gs/s. The diameter of the final field volume is 24 mm, its length is /spl sim/100 mm.\",\"PeriodicalId\":11209,\"journal\":{\"name\":\"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)\",\"volume\":\"27 1\",\"pages\":\"746-749 vol.2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPC.1999.823621\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. 12th IEEE International Pulsed Power Conference. (Cat. No.99CH36358)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1999.823621","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Many years work on the development of magnetocumulative generators of ultra-high magnetic fields has led to the creation of the cascade MC-1 generator, in which a magnetic field of more than 28 MGs was recorded in 1998. This device consists of a generator solenoid (the first cascade) with internal and external diameters of 175 mm and 200 mm respectively and a length of 500 mm, and two internal cascades with diameters of 28/spl times/35 mm and 12/spl times/17 mm and a length of /spl sim/200 mm. One-cascade system of explosive compression, consisting of the main HE-charge with diameters of 360/spl times/650 mm, a length of 350 mm and a mass of /spl sim/170 kg, steel cylinder-impactor with an external diameter of 356 mm and a thickness of 7 mm, and internal HE-charge with diameters of 200/spl times/300 mm and a length of 280 mm, is located on the outside of the solenoid. The MC-1 generator solenoid is powered with a current of 4-5 MA. MC-1 generator operation time (without powering time and HE-charge detonation time) is about 15 /spl mu/s, maximum liner implosion velocity is more than 6 km/s, the magnetic field derivative reaches values of /spl sim/5 10/sub 13/ Gs/s. The diameter of the final field volume is 24 mm, its length is /spl sim/100 mm.