{"title":"PENERAPAN SSDE-DIAMETER EKUIVALEN AIR SEBAGAI TINGKAT PANDUAN DIAGNOSIS TYPICAL VALUE PADA PEMERIKSAAN CT SCAN ABDOMEN PEDIATRIK","authors":"Ni Larasati Kartika Sari, Rahayugo Rahayugo, B. Santoso, Puji Hartoyo","doi":"10.19184/jpf.v12i2.39048","DOIUrl":null,"url":null,"abstract":"Diagnostic Reference Level (DRL) is a method of optimizing patient doses in diagnostic and intervention procedures. The DRL value is obtained from the Volumetric Computed Tomography Dose Index (CTDIvol) which is obtained from a phantom with a diameter of 16 cm or 32 cm, so it is not yet possible to accurately estimate the dose for each patient, especially pediatric patients. The American Association of Physicists in Medicine (AAPM) then issued a water equivalent diameter (Dw) parameter to calibrate the CTDIvol to obtain a Size-Specific Dose Estimate (SSDE) so that it is more specific and effective. This study aims to obtain local DRL values ​​and compare local DRL values ​​in two pediatric age groups. This study used data from 25 pediatric abdominal CT scan patients aged <15 years, divided into two groups, ages 0-4 years and ages 5-15 years. The results of this study showed that typical  DRLCTDIvol values ​​for ages 0-4 years and 5-15 years were 3.09 mGy and 4.39 mGy respectively, while DRLSSDE for the two age groups were 3.25 mGy and 3.54 mGy respectively. There is a difference of 5.27% and 19.36% respectively from the local DRL value based on CTDIvol and SSDE for the two age groups. It can be seen that in the 0-4 year age group, the DRLSSDE value is greater than the DRLCTDIvol, conversely in the 5-15 year age group the DRLSSDE value is lower than the DRLCTDIvol which indicates that the dimensional factor affects the dose received by the patient.","PeriodicalId":33966,"journal":{"name":"Gravity Jurnal Ilmiah Penelitian dan Pembelajaran Fisika","volume":"44 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gravity Jurnal Ilmiah Penelitian dan Pembelajaran Fisika","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19184/jpf.v12i2.39048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

诊断参考水平(DRL)是一种在诊断和干预程序中优化患者剂量的方法。DRL值是通过体积计算机断层扫描剂量指数(CTDIvol)获得的,该指数是从直径为16厘米或32厘米的幻影中获得的,因此尚不能准确估计每个患者的剂量,特别是儿科患者。美国医学物理学家协会(AAPM)随后发布了一个水当量直径(Dw)参数来校准CTDIvol,以获得一个尺寸特异性剂量估计(SSDE),从而使其更加特异性和有效。本研究旨在获得局部DRL值,并比较两个儿童年龄组的局部DRL值。本研究使用25例年龄<15岁的儿童腹部CT扫描患者的数据,分为两组,年龄为0-4岁和5-15岁。本研究结果显示,0-4岁和5-15岁典型DRLCTDIvol值分别为3.09 mGy和4.39 mGy,而两个年龄组的DRLSSDE值分别为3.25 mGy和3.54 mGy。与基于CTDIvol和SSDE的本地DRL值相比,两个年龄组的差异分别为5.27%和19.36%。可以看出,0-4岁年龄组的DRLSSDE值大于DRLCTDIvol,相反,5-15岁年龄组的DRLSSDE值低于DRLCTDIvol,说明尺寸因素影响了患者接受的剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
PENERAPAN SSDE-DIAMETER EKUIVALEN AIR SEBAGAI TINGKAT PANDUAN DIAGNOSIS TYPICAL VALUE PADA PEMERIKSAAN CT SCAN ABDOMEN PEDIATRIK
Diagnostic Reference Level (DRL) is a method of optimizing patient doses in diagnostic and intervention procedures. The DRL value is obtained from the Volumetric Computed Tomography Dose Index (CTDIvol) which is obtained from a phantom with a diameter of 16 cm or 32 cm, so it is not yet possible to accurately estimate the dose for each patient, especially pediatric patients. The American Association of Physicists in Medicine (AAPM) then issued a water equivalent diameter (Dw) parameter to calibrate the CTDIvol to obtain a Size-Specific Dose Estimate (SSDE) so that it is more specific and effective. This study aims to obtain local DRL values ​​and compare local DRL values ​​in two pediatric age groups. This study used data from 25 pediatric abdominal CT scan patients aged <15 years, divided into two groups, ages 0-4 years and ages 5-15 years. The results of this study showed that typical  DRLCTDIvol values ​​for ages 0-4 years and 5-15 years were 3.09 mGy and 4.39 mGy respectively, while DRLSSDE for the two age groups were 3.25 mGy and 3.54 mGy respectively. There is a difference of 5.27% and 19.36% respectively from the local DRL value based on CTDIvol and SSDE for the two age groups. It can be seen that in the 0-4 year age group, the DRLSSDE value is greater than the DRLCTDIvol, conversely in the 5-15 year age group the DRLSSDE value is lower than the DRLCTDIvol which indicates that the dimensional factor affects the dose received by the patient.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信