D.C. Panigrahi , M.L. Gupta , S.P. Banerjee
{"title":"印度板柱工作面热流与温升的实证研究","authors":"D.C. Panigrahi ,&nbsp;M.L. Gupta ,&nbsp;S.P. Banerjee","doi":"10.1016/0167-9031(91)91609-L","DOIUrl":null,"url":null,"abstract":"<div><p>Results of investigations into climatic conditions in 19 bord-and-pillar semi-mechanised panels in the Raniganj coalfield in India are presented. Variables affecting transfer of heat and moisture and resulting rises in wet bulb and dry bulb temperatures in the panel have been critically investigated and statistical methods employed to identify the five most significant variables. These are: the temperature difference between virgin rock and air; air flow rate; average rate of advance of the panel; length of air flow path in the panel; and the wetness of roadways.</p><p>Regression equations have been worked out to give: the rise in dry bulb air temperature; rise in wet bulb temperature; gain in specific enthalpy; and gain in moisture content in the panel; in terms of the five variables mentioned earlier.</p></div>","PeriodicalId":100929,"journal":{"name":"Mining Science and Technology","volume":"12 2","pages":"Pages 127-136"},"PeriodicalIF":0.0000,"publicationDate":"1991-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-9031(91)91609-L","citationCount":"0","resultStr":"{\"title\":\"An empirical study of heat flow and temperature rise in bord-and-pillar workings in India\",\"authors\":\"D.C. Panigrahi ,&nbsp;M.L. Gupta ,&nbsp;S.P. Banerjee\",\"doi\":\"10.1016/0167-9031(91)91609-L\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Results of investigations into climatic conditions in 19 bord-and-pillar semi-mechanised panels in the Raniganj coalfield in India are presented. Variables affecting transfer of heat and moisture and resulting rises in wet bulb and dry bulb temperatures in the panel have been critically investigated and statistical methods employed to identify the five most significant variables. These are: the temperature difference between virgin rock and air; air flow rate; average rate of advance of the panel; length of air flow path in the panel; and the wetness of roadways.</p><p>Regression equations have been worked out to give: the rise in dry bulb air temperature; rise in wet bulb temperature; gain in specific enthalpy; and gain in moisture content in the panel; in terms of the five variables mentioned earlier.</p></div>\",\"PeriodicalId\":100929,\"journal\":{\"name\":\"Mining Science and Technology\",\"volume\":\"12 2\",\"pages\":\"Pages 127-136\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0167-9031(91)91609-L\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mining Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/016790319191609L\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mining Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/016790319191609L","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了印度拉尼甘杰煤田19个板柱式半机械化采煤板的气候条件调查结果。影响热量和水分传递的变量以及导致面板中湿球温度和干球温度上升的变量已被严格调查,并采用统计方法确定五个最重要的变量。它们是:原始岩石和空气之间的温差;空气流量;面板的平均推进率;面板内气流路径长度;还有潮湿的道路。回归方程给出了:干球温度的升高;湿球温度升高;比焓增益;以及面板中水分含量的增加;根据前面提到的五个变量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An empirical study of heat flow and temperature rise in bord-and-pillar workings in India

Results of investigations into climatic conditions in 19 bord-and-pillar semi-mechanised panels in the Raniganj coalfield in India are presented. Variables affecting transfer of heat and moisture and resulting rises in wet bulb and dry bulb temperatures in the panel have been critically investigated and statistical methods employed to identify the five most significant variables. These are: the temperature difference between virgin rock and air; air flow rate; average rate of advance of the panel; length of air flow path in the panel; and the wetness of roadways.

Regression equations have been worked out to give: the rise in dry bulb air temperature; rise in wet bulb temperature; gain in specific enthalpy; and gain in moisture content in the panel; in terms of the five variables mentioned earlier.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信