生物气候建筑在武吉士乡土住宅中的表现:以吉达和南马达住宅为例

A. M. Nugroho
{"title":"生物气候建筑在武吉士乡土住宅中的表现:以吉达和南马达住宅为例","authors":"A. M. Nugroho","doi":"10.9744/dimensi.48.2.131-140","DOIUrl":null,"url":null,"abstract":"Bioclimatic architecture is composed of climate-responsive knowledge in vernacular buildings as an effort to create comfortable conditions. This study aims to evaluate the suitability of the application of bioclimatic design to the performance of the thermal environment in one type of Bugis house. The method used is visual assessment and measurement of temperature and humidity in the case studies of Jida and Lammada houses, South Sulawesi. The results of visual observations show the accuracy of the bioclimatic design on the volume and slope elements of the roof; wall type and material; floor height and shade tree layout. The performance of the thermal environment in the living room and bedroom of Lammada house is better than similar rooms at Jida house. The bioclimatic elements that affect the performance of the thermal environment are the volume of the roof, the type and material of the walls and the height of the floor.","PeriodicalId":30518,"journal":{"name":"Dimensi Journal of Architecture and Built Environment","volume":"41 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"PERFORMANCE OF BIOCLIMATIC ARCHITECTURE IN BUGIS VERNACULAR HOUSING: A CASE STUDY OF JIDA AND LAMMADA HOUSES\",\"authors\":\"A. M. Nugroho\",\"doi\":\"10.9744/dimensi.48.2.131-140\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Bioclimatic architecture is composed of climate-responsive knowledge in vernacular buildings as an effort to create comfortable conditions. This study aims to evaluate the suitability of the application of bioclimatic design to the performance of the thermal environment in one type of Bugis house. The method used is visual assessment and measurement of temperature and humidity in the case studies of Jida and Lammada houses, South Sulawesi. The results of visual observations show the accuracy of the bioclimatic design on the volume and slope elements of the roof; wall type and material; floor height and shade tree layout. The performance of the thermal environment in the living room and bedroom of Lammada house is better than similar rooms at Jida house. The bioclimatic elements that affect the performance of the thermal environment are the volume of the roof, the type and material of the walls and the height of the floor.\",\"PeriodicalId\":30518,\"journal\":{\"name\":\"Dimensi Journal of Architecture and Built Environment\",\"volume\":\"41 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dimensi Journal of Architecture and Built Environment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.9744/dimensi.48.2.131-140\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dimensi Journal of Architecture and Built Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9744/dimensi.48.2.131-140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

生物气候建筑是在乡土建筑中运用气候响应知识,努力创造舒适的环境。本研究旨在评价生物气候设计应用于某类布吉住宅热环境性能的适宜性。在南苏拉威西岛Jida和Lammada房屋的案例研究中,使用的方法是目视评估和测量温度和湿度。视觉观察结果表明,生物气候设计对屋顶体量和坡度要素的影响是准确的;墙体类型及材质;楼层高度和树荫布局。Lammada住宅的客厅和卧室的热环境性能优于吉达住宅的同类房间。影响热环境性能的生物气候因素是屋顶的体积、墙壁的类型和材料以及地板的高度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
PERFORMANCE OF BIOCLIMATIC ARCHITECTURE IN BUGIS VERNACULAR HOUSING: A CASE STUDY OF JIDA AND LAMMADA HOUSES
Bioclimatic architecture is composed of climate-responsive knowledge in vernacular buildings as an effort to create comfortable conditions. This study aims to evaluate the suitability of the application of bioclimatic design to the performance of the thermal environment in one type of Bugis house. The method used is visual assessment and measurement of temperature and humidity in the case studies of Jida and Lammada houses, South Sulawesi. The results of visual observations show the accuracy of the bioclimatic design on the volume and slope elements of the roof; wall type and material; floor height and shade tree layout. The performance of the thermal environment in the living room and bedroom of Lammada house is better than similar rooms at Jida house. The bioclimatic elements that affect the performance of the thermal environment are the volume of the roof, the type and material of the walls and the height of the floor.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信