{"title":"住宅和工业房间火灾探测器的新功能可能性","authors":"V. Kitikov, E. Ternov, A. V. Danilenko, N. Mukhurov, S. V. Denisyuk","doi":"10.21122/2220-9506-2019-10-4-341-352","DOIUrl":null,"url":null,"abstract":"The relevance of early detection of fire signs is quite obvious because due to the necessary measures for evacuating of people and material values, disconnecting the electrical equipment and extinguishing the fire at the time of the onset of fire or passive smoldering, human casualties can be completely avoided and economic losses can be minimized.A graphical representation of fire detectors' the classification in the form of a generalized scheme using all the main classification features, their advantages and disadvantages is given. The optimal areas for the use of detectors depending on the fire load are determined. The effectiveness of combined fire detectors' use, equipped in addition to traditional smoke and heat sensors with gas sensors, as an integrated approach to the organization of control over protected objects is shown.The results of development of highly sensitive two-zone sensor with sensitive elements based on iron oxide films for detecting the release of explosive and poisonous gases in the initial stage of decay before the formation of ignition conditions are presented. The use of gas sensors that respond to hazardous gases in the environment significantly reduces the risk of death due to carbon monoxide poisoning.","PeriodicalId":41798,"journal":{"name":"Devices and Methods of Measurements","volume":"2 1","pages":""},"PeriodicalIF":0.2000,"publicationDate":"2019-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"New Functional Possibilities of Fire Detectors for Residential and Industrial Rooms\",\"authors\":\"V. Kitikov, E. Ternov, A. V. Danilenko, N. Mukhurov, S. V. Denisyuk\",\"doi\":\"10.21122/2220-9506-2019-10-4-341-352\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The relevance of early detection of fire signs is quite obvious because due to the necessary measures for evacuating of people and material values, disconnecting the electrical equipment and extinguishing the fire at the time of the onset of fire or passive smoldering, human casualties can be completely avoided and economic losses can be minimized.A graphical representation of fire detectors' the classification in the form of a generalized scheme using all the main classification features, their advantages and disadvantages is given. The optimal areas for the use of detectors depending on the fire load are determined. The effectiveness of combined fire detectors' use, equipped in addition to traditional smoke and heat sensors with gas sensors, as an integrated approach to the organization of control over protected objects is shown.The results of development of highly sensitive two-zone sensor with sensitive elements based on iron oxide films for detecting the release of explosive and poisonous gases in the initial stage of decay before the formation of ignition conditions are presented. The use of gas sensors that respond to hazardous gases in the environment significantly reduces the risk of death due to carbon monoxide poisoning.\",\"PeriodicalId\":41798,\"journal\":{\"name\":\"Devices and Methods of Measurements\",\"volume\":\"2 1\",\"pages\":\"\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2019-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Devices and Methods of Measurements\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21122/2220-9506-2019-10-4-341-352\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Devices and Methods of Measurements","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21122/2220-9506-2019-10-4-341-352","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

早期发现火灾迹象的相关性是非常明显的,因为在火灾或被动阴燃发生时,由于采取了疏散人员和物资、断开电气设备和灭火的必要措施,可以完全避免人员伤亡,最大限度地减少经济损失。用广义方案的形式对火灾探测器的分类进行了图解,给出了所有主要分类特征的优缺点。根据火灾负荷确定探测器的最佳使用区域。结合火灾探测器的有效性,除了配备传统的烟雾和热传感器与气体传感器,作为一个综合的方法来组织控制受保护的对象显示。本文介绍了一种基于氧化铁薄膜的高灵敏度双区传感器的研制结果,该传感器可用于在燃烧条件形成前的衰变初始阶段检测爆炸和有毒气体的释放。对环境中的有害气体作出反应的气体传感器的使用大大降低了因一氧化碳中毒而死亡的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
New Functional Possibilities of Fire Detectors for Residential and Industrial Rooms
The relevance of early detection of fire signs is quite obvious because due to the necessary measures for evacuating of people and material values, disconnecting the electrical equipment and extinguishing the fire at the time of the onset of fire or passive smoldering, human casualties can be completely avoided and economic losses can be minimized.A graphical representation of fire detectors' the classification in the form of a generalized scheme using all the main classification features, their advantages and disadvantages is given. The optimal areas for the use of detectors depending on the fire load are determined. The effectiveness of combined fire detectors' use, equipped in addition to traditional smoke and heat sensors with gas sensors, as an integrated approach to the organization of control over protected objects is shown.The results of development of highly sensitive two-zone sensor with sensitive elements based on iron oxide films for detecting the release of explosive and poisonous gases in the initial stage of decay before the formation of ignition conditions are presented. The use of gas sensors that respond to hazardous gases in the environment significantly reduces the risk of death due to carbon monoxide poisoning.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Devices and Methods of Measurements
Devices and Methods of Measurements INSTRUMENTS & INSTRUMENTATION-
自引率
25.00%
发文量
18
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信