{"title":"高分辨率12导联心电图p波检测和分割的鲁棒程序","authors":"O. Escalona, L. Gavidia, G. Wright","doi":"10.1109/IEMBS.1996.647456","DOIUrl":null,"url":null,"abstract":"Reliable detection and measurement of the P-wave duration and position in high resolution 12-lead ECG recordings, was automated by means of a computer procedure which involved noise reduction by means of signal averaging, and bi-directional filtering of the P-wave at 25 Hz and the QRS complex at 40 Hz Then, algorithms for P-onset, P-offset and QRS-onset detection, allowed the estimation of P-wave duration and PQ interval, This computer procedure was clinically tested with 52 volunteers. The results indicated that, although reliable P-wave detection was possible in at least three leads in ally case, the measurement technique was most robust with leads I, II and V/sub 4/.","PeriodicalId":20427,"journal":{"name":"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"39 1","pages":"1365-1366 vol.4"},"PeriodicalIF":0.0000,"publicationDate":"1996-11-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A robust procedure for P-wave detection and segmentation in high resolution 12-lead ECG\",\"authors\":\"O. Escalona, L. Gavidia, G. Wright\",\"doi\":\"10.1109/IEMBS.1996.647456\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reliable detection and measurement of the P-wave duration and position in high resolution 12-lead ECG recordings, was automated by means of a computer procedure which involved noise reduction by means of signal averaging, and bi-directional filtering of the P-wave at 25 Hz and the QRS complex at 40 Hz Then, algorithms for P-onset, P-offset and QRS-onset detection, allowed the estimation of P-wave duration and PQ interval, This computer procedure was clinically tested with 52 volunteers. The results indicated that, although reliable P-wave detection was possible in at least three leads in ally case, the measurement technique was most robust with leads I, II and V/sub 4/.\",\"PeriodicalId\":20427,\"journal\":{\"name\":\"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":\"39 1\",\"pages\":\"1365-1366 vol.4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-11-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1996.647456\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1996.647456","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A robust procedure for P-wave detection and segmentation in high resolution 12-lead ECG
Reliable detection and measurement of the P-wave duration and position in high resolution 12-lead ECG recordings, was automated by means of a computer procedure which involved noise reduction by means of signal averaging, and bi-directional filtering of the P-wave at 25 Hz and the QRS complex at 40 Hz Then, algorithms for P-onset, P-offset and QRS-onset detection, allowed the estimation of P-wave duration and PQ interval, This computer procedure was clinically tested with 52 volunteers. The results indicated that, although reliable P-wave detection was possible in at least three leads in ally case, the measurement technique was most robust with leads I, II and V/sub 4/.