{"title":"半导体屏蔽和XLPE绝缘组合对电气树起始的影响","authors":"S. Moody, R. N. Hampton","doi":"10.1109/ICSD.1998.709237","DOIUrl":null,"url":null,"abstract":"Electrical tree inception tests have been carried out on different combinations of semiconductive screen (semicon) needle/XLPE insulation samples. The test programme has been designed so that it is possible to ascertain the main factors which promote or retard electrical tree inception. The results obtained have permitted predictions to be made of the most appropriate material combinations. The analysis shows that the interaction between the insulation and the semicon is highly significant and in fact dominates the performance of the selected material combination. Thus it can be concluded that by careful design and selection of semicon/XLPE combinations, samples with enhanced electrical treeing properties can be manufactured.","PeriodicalId":13148,"journal":{"name":"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)","volume":"16 1","pages":"106-109"},"PeriodicalIF":0.0000,"publicationDate":"1998-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The effect of semiconductive screens and XLPE insulation combinations on electrical tree inception\",\"authors\":\"S. Moody, R. N. Hampton\",\"doi\":\"10.1109/ICSD.1998.709237\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Electrical tree inception tests have been carried out on different combinations of semiconductive screen (semicon) needle/XLPE insulation samples. The test programme has been designed so that it is possible to ascertain the main factors which promote or retard electrical tree inception. The results obtained have permitted predictions to be made of the most appropriate material combinations. The analysis shows that the interaction between the insulation and the semicon is highly significant and in fact dominates the performance of the selected material combination. Thus it can be concluded that by careful design and selection of semicon/XLPE combinations, samples with enhanced electrical treeing properties can be manufactured.\",\"PeriodicalId\":13148,\"journal\":{\"name\":\"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)\",\"volume\":\"16 1\",\"pages\":\"106-109\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSD.1998.709237\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSD.1998.709237","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在不同组合的半导体屏(半导体)针/XLPE绝缘样品上进行了电气树启动测试。设计了测试程序,以便能够确定促进或延迟电气树启动的主要因素。所得的结果允许对最适当的材料组合作出预测。分析表明,绝缘与半导体之间的相互作用非常显著,实际上主导着所选材料组合的性能。由此可以得出结论,通过精心设计和选择半导体/XLPE组合,可以制造出具有增强电树性能的样品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The effect of semiconductive screens and XLPE insulation combinations on electrical tree inception
Electrical tree inception tests have been carried out on different combinations of semiconductive screen (semicon) needle/XLPE insulation samples. The test programme has been designed so that it is possible to ascertain the main factors which promote or retard electrical tree inception. The results obtained have permitted predictions to be made of the most appropriate material combinations. The analysis shows that the interaction between the insulation and the semicon is highly significant and in fact dominates the performance of the selected material combination. Thus it can be concluded that by careful design and selection of semicon/XLPE combinations, samples with enhanced electrical treeing properties can be manufactured.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信