边界层分离对局部排气设计和工人暴露的影响

Dennis K. George, M. Flynn, R. Goodman
{"title":"边界层分离对局部排气设计和工人暴露的影响","authors":"Dennis K. George, M. Flynn, R. Goodman","doi":"10.1080/1047322X.1990.10389684","DOIUrl":null,"url":null,"abstract":"Abstract The phenomenon of boundary layer separation is an important factor in determining a worker's breathing zone concentration. This article presents the results of flow visualization and tracer gas studies, conducted in a wind tunnel with a mannequin, designed to examine this phenomenon. A simple conceptual model, based on mass transport by vortex shedding, provides a reasonable estimate of the mannequin's breathing zone concentration. An empirical model is developed which relates the measured concentration to the distance from the source to the breathing zone for the situation when the contaminant is released downstream in a uniform flow. Applications of the results are discussed.","PeriodicalId":8182,"journal":{"name":"Applied occupational and environmental hygiene","volume":"1 1","pages":"501-509"},"PeriodicalIF":0.0000,"publicationDate":"2011-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"The Impact of Boundary Layer Separation on Local Exhaust Design and Worker Exposure\",\"authors\":\"Dennis K. George, M. Flynn, R. Goodman\",\"doi\":\"10.1080/1047322X.1990.10389684\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The phenomenon of boundary layer separation is an important factor in determining a worker's breathing zone concentration. This article presents the results of flow visualization and tracer gas studies, conducted in a wind tunnel with a mannequin, designed to examine this phenomenon. A simple conceptual model, based on mass transport by vortex shedding, provides a reasonable estimate of the mannequin's breathing zone concentration. An empirical model is developed which relates the measured concentration to the distance from the source to the breathing zone for the situation when the contaminant is released downstream in a uniform flow. Applications of the results are discussed.\",\"PeriodicalId\":8182,\"journal\":{\"name\":\"Applied occupational and environmental hygiene\",\"volume\":\"1 1\",\"pages\":\"501-509\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied occupational and environmental hygiene\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/1047322X.1990.10389684\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied occupational and environmental hygiene","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/1047322X.1990.10389684","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

摘要边界层分离现象是决定工人呼吸区浓度的重要因素。本文介绍了流动可视化和示踪气体研究的结果,在风洞中与人体模型进行,旨在研究这种现象。一个简单的概念模型,基于质量传输的旋涡脱落,提供了一个合理的估计人体呼吸区浓度。针对污染物以均匀流向下游释放的情况,建立了将测量浓度与源到呼吸区的距离联系起来的经验模型。讨论了结果的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Impact of Boundary Layer Separation on Local Exhaust Design and Worker Exposure
Abstract The phenomenon of boundary layer separation is an important factor in determining a worker's breathing zone concentration. This article presents the results of flow visualization and tracer gas studies, conducted in a wind tunnel with a mannequin, designed to examine this phenomenon. A simple conceptual model, based on mass transport by vortex shedding, provides a reasonable estimate of the mannequin's breathing zone concentration. An empirical model is developed which relates the measured concentration to the distance from the source to the breathing zone for the situation when the contaminant is released downstream in a uniform flow. Applications of the results are discussed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信