接触载荷对生物复合材料摩擦-腐蚀磨损行为的影响:离轴滑动接触-咀嚼模拟

E. Yilmaz
{"title":"接触载荷对生物复合材料摩擦-腐蚀磨损行为的影响:离轴滑动接触-咀嚼模拟","authors":"E. Yilmaz","doi":"10.4103/bmrj.bmrj_2_20","DOIUrl":null,"url":null,"abstract":"Background: In recent years, the use of composite materials as biomaterials has been increasing in dentistry. It is important to perform in vitro experiments of biomaterials before living tissue. Aim: The purpose of this work was to examine the effect of contact load upon attrition-corrosion wear behavior of bio-composite materials: in vitro off-axis sliding contact chewing simulation. Material and Method: In this study, 2 mm × 12 mm (weight × diameter) cylindrical test specimens were prepared from Filtek Supreme and Clearfil AP-X bio-composite materials with different filler structure. The surface roughness and Vicker's Hardness values of the bio-composites were measured before the wear test procedures. Then, the test specimens were subjected to off-sliding abrasion test procedures under different mechanical loads in artificial saliva and citric acid medium. Wear volume loss of bio-composite materials was determined after wear test procedures using the three-dimensional noncontact profilometer. Results: As the mechanical loading increased, the loss of wear volume in both composite materials increased irrespective of test medium. However, this increase in wear volume loss in test specimens was more pronounced in the citric acid environment. Conclusion: As a result of, the organic matrix structure (such as Ba glass particle) of the composite material contributes to more volume loss in corrosive environment.","PeriodicalId":34293,"journal":{"name":"Biomedical Research Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Effect of contact load upon attrition-corrosion wear behavior of bio-composite materials: In vitro off-axis sliding contact-chewing simulation\",\"authors\":\"E. Yilmaz\",\"doi\":\"10.4103/bmrj.bmrj_2_20\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: In recent years, the use of composite materials as biomaterials has been increasing in dentistry. It is important to perform in vitro experiments of biomaterials before living tissue. Aim: The purpose of this work was to examine the effect of contact load upon attrition-corrosion wear behavior of bio-composite materials: in vitro off-axis sliding contact chewing simulation. Material and Method: In this study, 2 mm × 12 mm (weight × diameter) cylindrical test specimens were prepared from Filtek Supreme and Clearfil AP-X bio-composite materials with different filler structure. The surface roughness and Vicker's Hardness values of the bio-composites were measured before the wear test procedures. Then, the test specimens were subjected to off-sliding abrasion test procedures under different mechanical loads in artificial saliva and citric acid medium. Wear volume loss of bio-composite materials was determined after wear test procedures using the three-dimensional noncontact profilometer. Results: As the mechanical loading increased, the loss of wear volume in both composite materials increased irrespective of test medium. However, this increase in wear volume loss in test specimens was more pronounced in the citric acid environment. Conclusion: As a result of, the organic matrix structure (such as Ba glass particle) of the composite material contributes to more volume loss in corrosive environment.\",\"PeriodicalId\":34293,\"journal\":{\"name\":\"Biomedical Research Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Research Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/bmrj.bmrj_2_20\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/bmrj.bmrj_2_20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

背景:近年来,复合材料作为生物材料在牙科领域的应用越来越广泛。在活体组织之前进行生物材料的体外实验是很重要的。目的:研究接触载荷对生物复合材料摩擦腐蚀磨损行为的影响:体外离轴滑动接触咀嚼模拟。材料与方法:采用不同填充结构的Filtek Supreme和Clearfil AP-X生物复合材料制备2mm × 12mm(重量×直径)圆柱形试样。在进行磨损试验之前,测量了生物复合材料的表面粗糙度和维氏硬度值。然后对试件在人工唾液和柠檬酸介质中进行不同机械载荷下的脱滑磨损试验。在使用三维非接触式轮廓仪进行磨损试验后,确定了生物复合材料的磨损体积损失。结果:随着机械载荷的增加,两种复合材料的磨损体积损失均增加,与试验介质无关。然而,在柠檬酸环境中,试样磨损体积损失的增加更为明显。结论:复合材料的有机基体结构(如Ba玻璃颗粒)在腐蚀环境中导致了更大的体积损失。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of contact load upon attrition-corrosion wear behavior of bio-composite materials: In vitro off-axis sliding contact-chewing simulation
Background: In recent years, the use of composite materials as biomaterials has been increasing in dentistry. It is important to perform in vitro experiments of biomaterials before living tissue. Aim: The purpose of this work was to examine the effect of contact load upon attrition-corrosion wear behavior of bio-composite materials: in vitro off-axis sliding contact chewing simulation. Material and Method: In this study, 2 mm × 12 mm (weight × diameter) cylindrical test specimens were prepared from Filtek Supreme and Clearfil AP-X bio-composite materials with different filler structure. The surface roughness and Vicker's Hardness values of the bio-composites were measured before the wear test procedures. Then, the test specimens were subjected to off-sliding abrasion test procedures under different mechanical loads in artificial saliva and citric acid medium. Wear volume loss of bio-composite materials was determined after wear test procedures using the three-dimensional noncontact profilometer. Results: As the mechanical loading increased, the loss of wear volume in both composite materials increased irrespective of test medium. However, this increase in wear volume loss in test specimens was more pronounced in the citric acid environment. Conclusion: As a result of, the organic matrix structure (such as Ba glass particle) of the composite material contributes to more volume loss in corrosive environment.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信