J. P. Schwartz, Taisa Boamorte Ravelli, S. Ruf, D. B. Ravelli
{"title":"中药治疗引起的下颌犬齿舌侧倾和犬间距离的层析成像评价","authors":"J. P. Schwartz, Taisa Boamorte Ravelli, S. Ruf, D. B. Ravelli","doi":"10.4025/actascihealthsci.v45i1.60517","DOIUrl":null,"url":null,"abstract":"The aim of this study was to perform a three-dimensional evaluation of Herbst appliance effects on the mandibular canines.The subjects consisted of 23 Class II:1 patients (12 men, 11 women), mean age of 15.76± 1.75 years, consecutively treated with a Flip-Lock Herbst®appliance (TP Orthodontics, Inc., La Porte, IN, USA). The lower anchorage unit for the Herbst appliance consisted of two anchor bands connected by a lingual arch with 3mm distance from the incisor’s lingual surface. Treatment changes in mandibular canine inclination and mandibular intercanine width at the cusp and apex levels were evaluated by means of cone-beam computed tomography images (i-CAT® Classic unit, Imaging Sciences International, Hatfield, PA, USA) obtained before and after treatment with the Herbst appliance. There were no statistical differences between genders. Herbst appliance treatment did not result in any statistically significant changes for mandibular canine inclination and mandibular intercanine width. There were associations between mandibular canine inclination and mandibular intercanine width at the cusp (/r/ = 0.43 to 0.66) and apex levels (/r/ = 0.34 to 0.60). The three-dimensionalcone-beam computed tomography analysis of the mandibular canine segment revealed that the Herbst appliance with a mandibular anchorage unit distant from the incisor’s lingual surface does not change mandibular canine inclination and mandibular intercanine width significantly during treatment. However, large interindividual differences may result in undesired amount of mandibular canine anchorage loss in individual patients.","PeriodicalId":42839,"journal":{"name":"ACTA SCIENTIARUM-HEALTH SCIENCES","volume":"2009 1","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2023-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Tomographic evaluation of changes induced by herbst treatment - buccolingual inclination of mandibular canines and the intercanine distance\",\"authors\":\"J. P. Schwartz, Taisa Boamorte Ravelli, S. Ruf, D. B. Ravelli\",\"doi\":\"10.4025/actascihealthsci.v45i1.60517\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The aim of this study was to perform a three-dimensional evaluation of Herbst appliance effects on the mandibular canines.The subjects consisted of 23 Class II:1 patients (12 men, 11 women), mean age of 15.76± 1.75 years, consecutively treated with a Flip-Lock Herbst®appliance (TP Orthodontics, Inc., La Porte, IN, USA). The lower anchorage unit for the Herbst appliance consisted of two anchor bands connected by a lingual arch with 3mm distance from the incisor’s lingual surface. Treatment changes in mandibular canine inclination and mandibular intercanine width at the cusp and apex levels were evaluated by means of cone-beam computed tomography images (i-CAT® Classic unit, Imaging Sciences International, Hatfield, PA, USA) obtained before and after treatment with the Herbst appliance. There were no statistical differences between genders. Herbst appliance treatment did not result in any statistically significant changes for mandibular canine inclination and mandibular intercanine width. There were associations between mandibular canine inclination and mandibular intercanine width at the cusp (/r/ = 0.43 to 0.66) and apex levels (/r/ = 0.34 to 0.60). The three-dimensionalcone-beam computed tomography analysis of the mandibular canine segment revealed that the Herbst appliance with a mandibular anchorage unit distant from the incisor’s lingual surface does not change mandibular canine inclination and mandibular intercanine width significantly during treatment. However, large interindividual differences may result in undesired amount of mandibular canine anchorage loss in individual patients.\",\"PeriodicalId\":42839,\"journal\":{\"name\":\"ACTA SCIENTIARUM-HEALTH SCIENCES\",\"volume\":\"2009 1\",\"pages\":\"\"},\"PeriodicalIF\":0.1000,\"publicationDate\":\"2023-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACTA SCIENTIARUM-HEALTH SCIENCES\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4025/actascihealthsci.v45i1.60517\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACTA SCIENTIARUM-HEALTH SCIENCES","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4025/actascihealthsci.v45i1.60517","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0
摘要
本研究的目的是进行赫氏矫治器对下颌犬齿的三维评价。受试者包括23例II:1例患者(男性12例,女性11例),平均年龄15.76±1.75岁,连续使用fliplock Herbst®矫治器(TP Orthodontics, Inc., La Porte, IN, USA)进行治疗。Herbst矫治器的下锚定单元由两个锚定带组成,由距切牙舌面3mm距离的舌弓连接。使用Herbst矫治器治疗前后,通过锥形束计算机断层扫描图像(i-CAT®Classic unit, Imaging Sciences International, Hatfield, PA, USA)评估下颌犬齿倾斜度和下颌犬齿间宽度的治疗变化。性别间无统计学差异。赫布斯特矫治器治疗对下颌犬齿倾斜度和下颌犬齿间宽度没有任何统计学意义上的改变。下颌犬齿倾斜度与下颌尖间宽度(/r/ = 0.43 ~ 0.66)和下颌尖间宽度(/r/ = 0.34 ~ 0.60)呈正相关。对下颌犬齿段的三维锥束计算机断层分析显示,在治疗过程中,Herbst矫治器的下颌支抗单元距离切牙舌面较远,对下颌犬齿的倾斜度和下颌犬齿间宽度没有明显的影响。然而,较大的个体间差异可能导致个体患者下颌犬齿支抗损失的不期望数量。
Tomographic evaluation of changes induced by herbst treatment - buccolingual inclination of mandibular canines and the intercanine distance
The aim of this study was to perform a three-dimensional evaluation of Herbst appliance effects on the mandibular canines.The subjects consisted of 23 Class II:1 patients (12 men, 11 women), mean age of 15.76± 1.75 years, consecutively treated with a Flip-Lock Herbst®appliance (TP Orthodontics, Inc., La Porte, IN, USA). The lower anchorage unit for the Herbst appliance consisted of two anchor bands connected by a lingual arch with 3mm distance from the incisor’s lingual surface. Treatment changes in mandibular canine inclination and mandibular intercanine width at the cusp and apex levels were evaluated by means of cone-beam computed tomography images (i-CAT® Classic unit, Imaging Sciences International, Hatfield, PA, USA) obtained before and after treatment with the Herbst appliance. There were no statistical differences between genders. Herbst appliance treatment did not result in any statistically significant changes for mandibular canine inclination and mandibular intercanine width. There were associations between mandibular canine inclination and mandibular intercanine width at the cusp (/r/ = 0.43 to 0.66) and apex levels (/r/ = 0.34 to 0.60). The three-dimensionalcone-beam computed tomography analysis of the mandibular canine segment revealed that the Herbst appliance with a mandibular anchorage unit distant from the incisor’s lingual surface does not change mandibular canine inclination and mandibular intercanine width significantly during treatment. However, large interindividual differences may result in undesired amount of mandibular canine anchorage loss in individual patients.
期刊介绍:
The journal publishes original papers in Health Sciences, such as Clinical Analyses; Physical Education, Nursing, Pharmacy; Pharmacology, Phoniatry and Audiology, Physiotherapy and Occupational Therapy, Medicine, Nutrition, Dentistry and Public Health Policies.