{"title":"一种检测静电沉淀中火花的新方法","authors":"Zhuohan Li, Cheng Shao, C. Zhong, Yi An","doi":"10.1109/ICIST.2011.5765157","DOIUrl":null,"url":null,"abstract":"Spark detection is an important problem in electrostatic precipitation. This paper proposes a new method for detecting the spark based on the load voltage variety. In order to obtain this variety, the control model of the power supply is established, and then the mathematical expression of the load voltage can be formulated. By analyzing the features of the spark breakdown, it is observed that the load voltage variety during the spark breakdown is much larger than that of normal condition. Therefore, the maximum variety of the load voltage under normal condition can be considered as the detection threshold. In addition, the control method which tracks the dielectric strength recovery curve is also presented. The simulations and experiments demonstrate that the proposed method is effective.","PeriodicalId":6408,"journal":{"name":"2009 International Conference on Environmental Science and Information Application Technology","volume":"6 1","pages":"1074-1080"},"PeriodicalIF":0.0000,"publicationDate":"2011-03-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A new method for detecting spark in electrostatic precipitation\",\"authors\":\"Zhuohan Li, Cheng Shao, C. Zhong, Yi An\",\"doi\":\"10.1109/ICIST.2011.5765157\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Spark detection is an important problem in electrostatic precipitation. This paper proposes a new method for detecting the spark based on the load voltage variety. In order to obtain this variety, the control model of the power supply is established, and then the mathematical expression of the load voltage can be formulated. By analyzing the features of the spark breakdown, it is observed that the load voltage variety during the spark breakdown is much larger than that of normal condition. Therefore, the maximum variety of the load voltage under normal condition can be considered as the detection threshold. In addition, the control method which tracks the dielectric strength recovery curve is also presented. The simulations and experiments demonstrate that the proposed method is effective.\",\"PeriodicalId\":6408,\"journal\":{\"name\":\"2009 International Conference on Environmental Science and Information Application Technology\",\"volume\":\"6 1\",\"pages\":\"1074-1080\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-03-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2009 International Conference on Environmental Science and Information Application Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICIST.2011.5765157\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2009 International Conference on Environmental Science and Information Application Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICIST.2011.5765157","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A new method for detecting spark in electrostatic precipitation
Spark detection is an important problem in electrostatic precipitation. This paper proposes a new method for detecting the spark based on the load voltage variety. In order to obtain this variety, the control model of the power supply is established, and then the mathematical expression of the load voltage can be formulated. By analyzing the features of the spark breakdown, it is observed that the load voltage variety during the spark breakdown is much larger than that of normal condition. Therefore, the maximum variety of the load voltage under normal condition can be considered as the detection threshold. In addition, the control method which tracks the dielectric strength recovery curve is also presented. The simulations and experiments demonstrate that the proposed method is effective.