快速气相色谱/质谱分析,支持基于风险的决策

Albert Robbat Jr., Sigurdur Smarason, Yuri Gankin
{"title":"快速气相色谱/质谱分析,支持基于风险的决策","authors":"Albert Robbat Jr.,&nbsp;Sigurdur Smarason,&nbsp;Yuri Gankin","doi":"10.1002/(SICI)1520-6521(1999)3:1<55::AID-FACT7>3.0.CO;2-M","DOIUrl":null,"url":null,"abstract":"<p>A new data analysis software system (Ion Fingerprint Detection<sup>TM</sup>) has been developed to provide fast mass spectral data analysis. Methods have been developed that can provide screening to quantitative gas chromatography/mass spectrometry (GC/MS) data in 30 s to minutes. Compound selectivity is provided through a unique set of algorithms rather than GC separation. The data quality produced for volatile and semivolatile organic contaminants under fast GC/MS conditions during dynamic site investigations carried out at Hanscom Air Force Base (Bedford, MA) and Joliet Army Ammunition Plant (Joliet, IL) are discussed. More than 800 samples were analyzed in each project, with state and federal regulators accepting the data to complete remedial investigation/feasibility (RI/FS) studies. ©1999 John Wiley &amp; Sons, Inc. Field Analyt Chem Technol 3:55–66, 1999</p>","PeriodicalId":100527,"journal":{"name":"Field Analytical Chemistry & Technology","volume":"3 1","pages":"55-66"},"PeriodicalIF":0.0000,"publicationDate":"1999-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1520-6521(1999)3:1<55::AID-FACT7>3.0.CO;2-M","citationCount":"27","resultStr":"{\"title\":\"Fast gas chromatography/mass spectrometry analysis in support of risk-based decisions\",\"authors\":\"Albert Robbat Jr.,&nbsp;Sigurdur Smarason,&nbsp;Yuri Gankin\",\"doi\":\"10.1002/(SICI)1520-6521(1999)3:1<55::AID-FACT7>3.0.CO;2-M\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A new data analysis software system (Ion Fingerprint Detection<sup>TM</sup>) has been developed to provide fast mass spectral data analysis. Methods have been developed that can provide screening to quantitative gas chromatography/mass spectrometry (GC/MS) data in 30 s to minutes. Compound selectivity is provided through a unique set of algorithms rather than GC separation. The data quality produced for volatile and semivolatile organic contaminants under fast GC/MS conditions during dynamic site investigations carried out at Hanscom Air Force Base (Bedford, MA) and Joliet Army Ammunition Plant (Joliet, IL) are discussed. More than 800 samples were analyzed in each project, with state and federal regulators accepting the data to complete remedial investigation/feasibility (RI/FS) studies. ©1999 John Wiley &amp; Sons, Inc. Field Analyt Chem Technol 3:55–66, 1999</p>\",\"PeriodicalId\":100527,\"journal\":{\"name\":\"Field Analytical Chemistry & Technology\",\"volume\":\"3 1\",\"pages\":\"55-66\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/(SICI)1520-6521(1999)3:1<55::AID-FACT7>3.0.CO;2-M\",\"citationCount\":\"27\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Field Analytical Chemistry & Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291520-6521%281999%293%3A1%3C55%3A%3AAID-FACT7%3E3.0.CO%3B2-M\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Field Analytical Chemistry & Technology","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291520-6521%281999%293%3A1%3C55%3A%3AAID-FACT7%3E3.0.CO%3B2-M","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 27

摘要

为了提供快速的质谱数据分析,开发了一种新的数据分析软件系统(Ion Fingerprint DetectionTM)。已经开发出可以在30秒到分钟内对定量气相色谱/质谱(GC/MS)数据进行筛选的方法。化合物选择性是通过一组独特的算法而不是GC分离来提供的。讨论了在Hanscom空军基地(Bedford, MA)和Joliet陆军弹药厂(Joliet, IL)进行的动态现场调查中,在快速GC/MS条件下对挥发性和半挥发性有机污染物产生的数据质量。每个项目分析了800多个样本,州和联邦监管机构接受了这些数据,以完成补救调查/可行性(RI/FS)研究。©1999 John Wiley &儿子,Inc。化学技术,1999 (3):55 - 66
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fast gas chromatography/mass spectrometry analysis in support of risk-based decisions

A new data analysis software system (Ion Fingerprint DetectionTM) has been developed to provide fast mass spectral data analysis. Methods have been developed that can provide screening to quantitative gas chromatography/mass spectrometry (GC/MS) data in 30 s to minutes. Compound selectivity is provided through a unique set of algorithms rather than GC separation. The data quality produced for volatile and semivolatile organic contaminants under fast GC/MS conditions during dynamic site investigations carried out at Hanscom Air Force Base (Bedford, MA) and Joliet Army Ammunition Plant (Joliet, IL) are discussed. More than 800 samples were analyzed in each project, with state and federal regulators accepting the data to complete remedial investigation/feasibility (RI/FS) studies. ©1999 John Wiley & Sons, Inc. Field Analyt Chem Technol 3:55–66, 1999

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信