{"title":"根据观察到的表观间距测定真实珠光体片层间距","authors":"H.S. Fong","doi":"10.1016/0026-0800(89)90029-3","DOIUrl":null,"url":null,"abstract":"<div><p>The method of Roosz, Gacsi, and Baan for determining true pearlite lamellar spacings from the apparent spacing frequencies observed on a metallographic surface is examined. It is shown that the method as it stands does not give very accurate results. Modifications to the method are proposed, and these are shown to lead to large improvements in the accuracy of the method.</p></div>","PeriodicalId":100918,"journal":{"name":"Metallography","volume":"23 3","pages":"Pages 173-188"},"PeriodicalIF":0.0000,"publicationDate":"1989-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0026-0800(89)90029-3","citationCount":"7","resultStr":"{\"title\":\"Determining true pearlite lamellar spacings from observed apparent spacings\",\"authors\":\"H.S. Fong\",\"doi\":\"10.1016/0026-0800(89)90029-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The method of Roosz, Gacsi, and Baan for determining true pearlite lamellar spacings from the apparent spacing frequencies observed on a metallographic surface is examined. It is shown that the method as it stands does not give very accurate results. Modifications to the method are proposed, and these are shown to lead to large improvements in the accuracy of the method.</p></div>\",\"PeriodicalId\":100918,\"journal\":{\"name\":\"Metallography\",\"volume\":\"23 3\",\"pages\":\"Pages 173-188\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0026-0800(89)90029-3\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metallography\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0026080089900293\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metallography","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0026080089900293","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Determining true pearlite lamellar spacings from observed apparent spacings
The method of Roosz, Gacsi, and Baan for determining true pearlite lamellar spacings from the apparent spacing frequencies observed on a metallographic surface is examined. It is shown that the method as it stands does not give very accurate results. Modifications to the method are proposed, and these are shown to lead to large improvements in the accuracy of the method.