外来离子对水样中Cr(VI)和Cr(III)的测定和形态的影响

IF 0.2 Q4 CHEMISTRY, MULTIDISCIPLINARY
{"title":"外来离子对水样中Cr(VI)和Cr(III)的测定和形态的影响","authors":"","doi":"10.35666/2232-7266.2023.60.04","DOIUrl":null,"url":null,"abstract":"This study reports: a) the content of Ca, Cd, Co, Cr(III), Cr(VI), Cu, Fe, K, Mg, Mn, Na, Ni, Pb, and Zn in wastewater from metal industries and rivers that flow near the metal processing industries; b) the possibility of quantitative determination of Cr(III) and Cr(VI) in the presence of the following cations: Fe3+, Cu2+, Ca2+, Mg2+, Ni2+, Mn2+; and Zn2+ and anions Cl-, NO3-, and SO42-; c) speciation of Cr(III) and Cr(VI) on silica gel modified with Nb2O5 . Metals were determined by flame atomic absorption spectrometry, except for Na and K, which were determined by atomic emission spectrometry, and Cr(VI) by ultraviolet-visible spectrophotometry. When the concentration of cations is higher than Mg2+ (>25 mg/L), Ni2+ (>100 mg/L), Fe3+ (>250 mg/L), Zn2+ (>500 mg/L), and Mn2+ (>1000 mg/L), an error greater than 10 % is obtained in the measurement of Cr(III) . Silica gel modified with Nb2O5 can be considered as an effective solid phase extraction adsorbent for speciation of Cr species and simultaneous concentration of Cr(III). The proposed method was successfully applied to the speciation and determination of Cr(III) and Cr(VI) in the analyzed samples. The content of almost all analyzed metals has been below the permitted values for wastewaters.","PeriodicalId":40710,"journal":{"name":"Glasnik Hemicara i Tehnologa Bosne i Hercegovine","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2023-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Influence of Foreign Ions on Determination and Speciation of Cr(VI) and Cr(III) from Water Samples\",\"authors\":\"\",\"doi\":\"10.35666/2232-7266.2023.60.04\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study reports: a) the content of Ca, Cd, Co, Cr(III), Cr(VI), Cu, Fe, K, Mg, Mn, Na, Ni, Pb, and Zn in wastewater from metal industries and rivers that flow near the metal processing industries; b) the possibility of quantitative determination of Cr(III) and Cr(VI) in the presence of the following cations: Fe3+, Cu2+, Ca2+, Mg2+, Ni2+, Mn2+; and Zn2+ and anions Cl-, NO3-, and SO42-; c) speciation of Cr(III) and Cr(VI) on silica gel modified with Nb2O5 . Metals were determined by flame atomic absorption spectrometry, except for Na and K, which were determined by atomic emission spectrometry, and Cr(VI) by ultraviolet-visible spectrophotometry. When the concentration of cations is higher than Mg2+ (>25 mg/L), Ni2+ (>100 mg/L), Fe3+ (>250 mg/L), Zn2+ (>500 mg/L), and Mn2+ (>1000 mg/L), an error greater than 10 % is obtained in the measurement of Cr(III) . Silica gel modified with Nb2O5 can be considered as an effective solid phase extraction adsorbent for speciation of Cr species and simultaneous concentration of Cr(III). The proposed method was successfully applied to the speciation and determination of Cr(III) and Cr(VI) in the analyzed samples. The content of almost all analyzed metals has been below the permitted values for wastewaters.\",\"PeriodicalId\":40710,\"journal\":{\"name\":\"Glasnik Hemicara i Tehnologa Bosne i Hercegovine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2023-06-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Glasnik Hemicara i Tehnologa Bosne i Hercegovine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.35666/2232-7266.2023.60.04\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Glasnik Hemicara i Tehnologa Bosne i Hercegovine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35666/2232-7266.2023.60.04","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

本研究报告了金属工业废水和金属加工业附近河流中Ca、Cd、Co、Cr(III)、Cr(VI)、Cu、Fe、K、Mg、Mn、Na、Ni、Pb、Zn的含量;b)在以下阳离子存在下定量测定Cr(III)和Cr(VI)的可能性:Fe3+, Cu2+, Ca2+, Mg2+, Ni2+, Mn2+;Zn2+和阴离子Cl-、NO3-、SO42-;c) Nb2O5修饰硅胶上Cr(III)和Cr(VI)的形态。除Na和K采用原子发射光谱法测定外,其余金属均采用火焰原子吸收光谱法测定,Cr(VI)采用紫外可见分光光度法测定。当阳离子浓度高于Mg2+ (>25 mg/L)、Ni2+ (>100 mg/L)、Fe3+ (>250 mg/L)、Zn2+ (>500 mg/L)和Mn2+ (>1000 mg/L)时,测量Cr(III)的误差大于10%。Nb2O5改性硅胶是一种有效的固相萃取吸附剂,可以吸附Cr的形态,同时吸附Cr(III)的浓度。该方法成功地应用于分析样品中Cr(III)和Cr(VI)的形成和测定。几乎所有分析过的金属含量都低于废水允许值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Influence of Foreign Ions on Determination and Speciation of Cr(VI) and Cr(III) from Water Samples
This study reports: a) the content of Ca, Cd, Co, Cr(III), Cr(VI), Cu, Fe, K, Mg, Mn, Na, Ni, Pb, and Zn in wastewater from metal industries and rivers that flow near the metal processing industries; b) the possibility of quantitative determination of Cr(III) and Cr(VI) in the presence of the following cations: Fe3+, Cu2+, Ca2+, Mg2+, Ni2+, Mn2+; and Zn2+ and anions Cl-, NO3-, and SO42-; c) speciation of Cr(III) and Cr(VI) on silica gel modified with Nb2O5 . Metals were determined by flame atomic absorption spectrometry, except for Na and K, which were determined by atomic emission spectrometry, and Cr(VI) by ultraviolet-visible spectrophotometry. When the concentration of cations is higher than Mg2+ (>25 mg/L), Ni2+ (>100 mg/L), Fe3+ (>250 mg/L), Zn2+ (>500 mg/L), and Mn2+ (>1000 mg/L), an error greater than 10 % is obtained in the measurement of Cr(III) . Silica gel modified with Nb2O5 can be considered as an effective solid phase extraction adsorbent for speciation of Cr species and simultaneous concentration of Cr(III). The proposed method was successfully applied to the speciation and determination of Cr(III) and Cr(VI) in the analyzed samples. The content of almost all analyzed metals has been below the permitted values for wastewaters.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Glasnik Hemicara i Tehnologa Bosne i Hercegovine
Glasnik Hemicara i Tehnologa Bosne i Hercegovine CHEMISTRY, MULTIDISCIPLINARY-
自引率
0.00%
发文量
6
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信