{"title":"使用脉冲电晕反应器进行化学破坏","authors":"K. Hutcherson, R. Roush, R. Brown","doi":"10.1109/PPC.1995.596472","DOIUrl":null,"url":null,"abstract":"Chemical destruction measurements for a Blumlein driven pulsed corona reactor are presented along with observed current and voltage waveforms. The input gas flow consists of 0.2 to 1.5 SLPM room temperature air with a 200 ppm toluene impurity. The PCR is operated with an applied voltage of between 12 to 30 kV at 5 to 50 Hz repetition rate. The dependence of the PCR chemical destruction on rep-rate, applied voltage and flow are reported. Apparatus to observe the relation between the emission spectra and the chemical destruction is discussed.","PeriodicalId":11163,"journal":{"name":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1995-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Chemical destruction using a pulsed corona reactor\",\"authors\":\"K. Hutcherson, R. Roush, R. Brown\",\"doi\":\"10.1109/PPC.1995.596472\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Chemical destruction measurements for a Blumlein driven pulsed corona reactor are presented along with observed current and voltage waveforms. The input gas flow consists of 0.2 to 1.5 SLPM room temperature air with a 200 ppm toluene impurity. The PCR is operated with an applied voltage of between 12 to 30 kV at 5 to 50 Hz repetition rate. The dependence of the PCR chemical destruction on rep-rate, applied voltage and flow are reported. Apparatus to observe the relation between the emission spectra and the chemical destruction is discussed.\",\"PeriodicalId\":11163,\"journal\":{\"name\":\"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-07-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PPC.1995.596472\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digest of Technical Papers. Tenth IEEE International Pulsed Power Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PPC.1995.596472","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Chemical destruction using a pulsed corona reactor
Chemical destruction measurements for a Blumlein driven pulsed corona reactor are presented along with observed current and voltage waveforms. The input gas flow consists of 0.2 to 1.5 SLPM room temperature air with a 200 ppm toluene impurity. The PCR is operated with an applied voltage of between 12 to 30 kV at 5 to 50 Hz repetition rate. The dependence of the PCR chemical destruction on rep-rate, applied voltage and flow are reported. Apparatus to observe the relation between the emission spectra and the chemical destruction is discussed.