基于局部放电在线监测的电力变压器绝缘状况评估

G. Ferraz, Laerty J. S. Damião, R. Capelini, R. Salustiano
{"title":"基于局部放电在线监测的电力变压器绝缘状况评估","authors":"G. Ferraz, Laerty J. S. Damião, R. Capelini, R. Salustiano","doi":"10.1109/ICEMPE51623.2021.9509243","DOIUrl":null,"url":null,"abstract":"The assessment of the insulation condition of a transformer is of great importance for the operational efficiency of the power system. However, as insulation systems are complex, many challenges are seen in terms of methods of analysis and measurement of critical parameters. In this context, this paper presents the application of an online monitoring system specially developed for the detection of partial discharges (PDs), which are recognized as a phenomenon that carries relevant information regarding the health of a transformer. The results were explored to show how the PD pattern and its correlation with gases dissolved in oil can be analyzed in practical situations with the equipment in service.","PeriodicalId":7083,"journal":{"name":"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)","volume":"29 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2021-04-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of the Insulation Conditions of Power Transformers Through Online Monitoring of Partial Discharges\",\"authors\":\"G. Ferraz, Laerty J. S. Damião, R. Capelini, R. Salustiano\",\"doi\":\"10.1109/ICEMPE51623.2021.9509243\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The assessment of the insulation condition of a transformer is of great importance for the operational efficiency of the power system. However, as insulation systems are complex, many challenges are seen in terms of methods of analysis and measurement of critical parameters. In this context, this paper presents the application of an online monitoring system specially developed for the detection of partial discharges (PDs), which are recognized as a phenomenon that carries relevant information regarding the health of a transformer. The results were explored to show how the PD pattern and its correlation with gases dissolved in oil can be analyzed in practical situations with the equipment in service.\",\"PeriodicalId\":7083,\"journal\":{\"name\":\"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)\",\"volume\":\"29 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-04-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICEMPE51623.2021.9509243\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 International Conference on Electrical Materials and Power Equipment (ICEMPE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICEMPE51623.2021.9509243","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

变压器绝缘状况的评估对电力系统的运行效率具有重要意义。然而,由于绝缘系统是复杂的,在关键参数的分析和测量方法方面存在许多挑战。在这种情况下,本文介绍了一种专门用于检测局部放电(pd)的在线监测系统的应用,局部放电被认为是一种携带有关变压器健康信息的现象。研究结果表明,在实际情况下,如何利用在役设备分析PD模式及其与油中溶解气体的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of the Insulation Conditions of Power Transformers Through Online Monitoring of Partial Discharges
The assessment of the insulation condition of a transformer is of great importance for the operational efficiency of the power system. However, as insulation systems are complex, many challenges are seen in terms of methods of analysis and measurement of critical parameters. In this context, this paper presents the application of an online monitoring system specially developed for the detection of partial discharges (PDs), which are recognized as a phenomenon that carries relevant information regarding the health of a transformer. The results were explored to show how the PD pattern and its correlation with gases dissolved in oil can be analyzed in practical situations with the equipment in service.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信