导尿管尖端诱导的ii型冠状动脉夹层通过支架置入左冠状动脉主干而脱离

Dibyasundar Mahanta, Jogendra Singh, Rudrapratap Mahapatra, R. Barik
{"title":"导尿管尖端诱导的ii型冠状动脉夹层通过支架置入左冠状动脉主干而脱离","authors":"Dibyasundar Mahanta, Jogendra Singh, Rudrapratap Mahapatra, R. Barik","doi":"10.4103/jicc.jicc_33_21","DOIUrl":null,"url":null,"abstract":"Left main coronary artery dissection induced by the tip of the guide catheter (Razor blade effect) with or without extension into the adjacent aortic wall can result in no flow. It is being a life threatening, complication and must be time timely detected and treated by stenting or surgery. A 59-year-old male patient presented with crescendo angina having a history of stenting to left anterior descending coronary artery (LAD) using 3 mm × 23 mm drug-eluting stent 5 years back. Coronary angiogram revealed 100% instent re-stenosis of the LAD. Left circumflex (LCX) coronary artery had proximal chronic total occlusion with J-CTO score of ≥2.The dominant right coronary artery was normal. LMCA dissection was noticed like an invisible dragon from nowhere after stenting of the proximal LCX followed by abrupt retrograde extension into aorta, resulting in no flow in the left coronary artery. The true lumen of LMCA was re-wired, and timely bailout stenting from LMCA to LCX was performed.","PeriodicalId":100789,"journal":{"name":"Journal of Indian College of Cardiology","volume":"58 1","pages":"133 - 135"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Guide catheter tip-induced type-II aortocoronary dissection bailed out by stenting the left main coronary artery\",\"authors\":\"Dibyasundar Mahanta, Jogendra Singh, Rudrapratap Mahapatra, R. Barik\",\"doi\":\"10.4103/jicc.jicc_33_21\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Left main coronary artery dissection induced by the tip of the guide catheter (Razor blade effect) with or without extension into the adjacent aortic wall can result in no flow. It is being a life threatening, complication and must be time timely detected and treated by stenting or surgery. A 59-year-old male patient presented with crescendo angina having a history of stenting to left anterior descending coronary artery (LAD) using 3 mm × 23 mm drug-eluting stent 5 years back. Coronary angiogram revealed 100% instent re-stenosis of the LAD. Left circumflex (LCX) coronary artery had proximal chronic total occlusion with J-CTO score of ≥2.The dominant right coronary artery was normal. LMCA dissection was noticed like an invisible dragon from nowhere after stenting of the proximal LCX followed by abrupt retrograde extension into aorta, resulting in no flow in the left coronary artery. The true lumen of LMCA was re-wired, and timely bailout stenting from LMCA to LCX was performed.\",\"PeriodicalId\":100789,\"journal\":{\"name\":\"Journal of Indian College of Cardiology\",\"volume\":\"58 1\",\"pages\":\"133 - 135\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian College of Cardiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jicc.jicc_33_21\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian College of Cardiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jicc.jicc_33_21","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

导尿管尖端引起的左主干冠状动脉剥离(剃刀效应)不论是否延伸至邻近主动脉壁均可导致无血流。这是一种危及生命的并发症,必须及时发现并通过支架植入或手术治疗。59岁男性患者,5年前曾行3 mm × 23 mm药物洗脱支架植入左冠状动脉前降支(LAD),以渐强型心绞痛就诊。冠状动脉造影显示前冠状动脉再狭窄100%。左旋冠状动脉近端慢性全闭塞,J-CTO评分≥2。右侧优势冠状动脉正常。在LMCA近端支架置入后,突然逆行延伸至主动脉,左冠状动脉无血流,发现LMCA夹层像一条看不见的龙,不知从哪里冒出来。重新连接LMCA真管腔,及时行LMCA至LCX救助支架置入。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Guide catheter tip-induced type-II aortocoronary dissection bailed out by stenting the left main coronary artery
Left main coronary artery dissection induced by the tip of the guide catheter (Razor blade effect) with or without extension into the adjacent aortic wall can result in no flow. It is being a life threatening, complication and must be time timely detected and treated by stenting or surgery. A 59-year-old male patient presented with crescendo angina having a history of stenting to left anterior descending coronary artery (LAD) using 3 mm × 23 mm drug-eluting stent 5 years back. Coronary angiogram revealed 100% instent re-stenosis of the LAD. Left circumflex (LCX) coronary artery had proximal chronic total occlusion with J-CTO score of ≥2.The dominant right coronary artery was normal. LMCA dissection was noticed like an invisible dragon from nowhere after stenting of the proximal LCX followed by abrupt retrograde extension into aorta, resulting in no flow in the left coronary artery. The true lumen of LMCA was re-wired, and timely bailout stenting from LMCA to LCX was performed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信