Rui Long, J. Ouyang, Feng Yang, Yan Li, Kaizhi Zhang, Longjian Zhou
{"title":"基于近场测量系统的相控阵标定方法","authors":"Rui Long, J. Ouyang, Feng Yang, Yan Li, Kaizhi Zhang, Longjian Zhou","doi":"10.1109/APS.2014.6904907","DOIUrl":null,"url":null,"abstract":"A new phased array calibration method based on near-field measurement system such as NSI is proposed in this paper. By measuring a single element antenna near-field and array near-field, calibration parameter is extracted from measured data with twice Fourier Transformation and once Inverse Fourier Transformation. Both amplitude and phase calibration is realized by this method in a very short time. A calibration example of a one-dimensional array is used to validate the proposed method.","PeriodicalId":6663,"journal":{"name":"2014 IEEE Antennas and Propagation Society International Symposium (APSURSI)","volume":"8 1","pages":"1161-1162"},"PeriodicalIF":0.0000,"publicationDate":"2014-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"21","resultStr":"{\"title\":\"Calibration method of phased array based on near-field measurement system\",\"authors\":\"Rui Long, J. Ouyang, Feng Yang, Yan Li, Kaizhi Zhang, Longjian Zhou\",\"doi\":\"10.1109/APS.2014.6904907\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A new phased array calibration method based on near-field measurement system such as NSI is proposed in this paper. By measuring a single element antenna near-field and array near-field, calibration parameter is extracted from measured data with twice Fourier Transformation and once Inverse Fourier Transformation. Both amplitude and phase calibration is realized by this method in a very short time. A calibration example of a one-dimensional array is used to validate the proposed method.\",\"PeriodicalId\":6663,\"journal\":{\"name\":\"2014 IEEE Antennas and Propagation Society International Symposium (APSURSI)\",\"volume\":\"8 1\",\"pages\":\"1161-1162\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2014 IEEE Antennas and Propagation Society International Symposium (APSURSI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APS.2014.6904907\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2014 IEEE Antennas and Propagation Society International Symposium (APSURSI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APS.2014.6904907","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Calibration method of phased array based on near-field measurement system
A new phased array calibration method based on near-field measurement system such as NSI is proposed in this paper. By measuring a single element antenna near-field and array near-field, calibration parameter is extracted from measured data with twice Fourier Transformation and once Inverse Fourier Transformation. Both amplitude and phase calibration is realized by this method in a very short time. A calibration example of a one-dimensional array is used to validate the proposed method.