{"title":"电树和空隙局部放电数据的统计特征和确定性","authors":"N. Chalashkanov, Conor P. Clarke, S. Dodd","doi":"10.1109/CEIDP50766.2021.9705473","DOIUrl":null,"url":null,"abstract":"Partial discharge (PD) data obtained from electrical trees and void experiments were analyzed. Several correlations were identified between the various statistical parameters traditionally used in PD classification and deterministic features such as average power dissipation. The correlation coefficients were found to have very high values in the case of electrical trees. Numerical simulations of PD activity in tree structures and voids were then used to explain the origin of the observed dependencies. The correlations between the statistical parameters describing the PD data identified in this work, could potentially be used to improve the robustness and reliability of defect classification based on PD measurements.","PeriodicalId":6837,"journal":{"name":"2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","volume":"36 1","pages":"598-602"},"PeriodicalIF":0.0000,"publicationDate":"2021-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Statistical Features and Determinism in Partial Discharge Data from Electrical Trees and Voids\",\"authors\":\"N. Chalashkanov, Conor P. Clarke, S. Dodd\",\"doi\":\"10.1109/CEIDP50766.2021.9705473\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Partial discharge (PD) data obtained from electrical trees and void experiments were analyzed. Several correlations were identified between the various statistical parameters traditionally used in PD classification and deterministic features such as average power dissipation. The correlation coefficients were found to have very high values in the case of electrical trees. Numerical simulations of PD activity in tree structures and voids were then used to explain the origin of the observed dependencies. The correlations between the statistical parameters describing the PD data identified in this work, could potentially be used to improve the robustness and reliability of defect classification based on PD measurements.\",\"PeriodicalId\":6837,\"journal\":{\"name\":\"2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"volume\":\"36 1\",\"pages\":\"598-602\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP50766.2021.9705473\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP50766.2021.9705473","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

对电树实验和空穴实验获得的局部放电数据进行了分析。在PD分类中常用的各种统计参数与平均功耗等确定性特征之间确定了若干相关性。在电树的情况下,相关系数被发现具有非常高的值。然后用树形结构和空洞中PD活性的数值模拟来解释观察到的依赖性的起源。在这项工作中确定的描述PD数据的统计参数之间的相关性可能用于提高基于PD测量的缺陷分类的鲁棒性和可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Statistical Features and Determinism in Partial Discharge Data from Electrical Trees and Voids
Partial discharge (PD) data obtained from electrical trees and void experiments were analyzed. Several correlations were identified between the various statistical parameters traditionally used in PD classification and deterministic features such as average power dissipation. The correlation coefficients were found to have very high values in the case of electrical trees. Numerical simulations of PD activity in tree structures and voids were then used to explain the origin of the observed dependencies. The correlations between the statistical parameters describing the PD data identified in this work, could potentially be used to improve the robustness and reliability of defect classification based on PD measurements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信