股骨粗隆间骨折手术固定后即刻评价颈轴角

Shubham Gupta, A. Bhandari
{"title":"股骨粗隆间骨折手术固定后即刻评价颈轴角","authors":"Shubham Gupta, A. Bhandari","doi":"10.22271/ortho.2023.v9.i2c.3371","DOIUrl":null,"url":null,"abstract":"Background: The angle between femur neck and the long axis of shaft is known as neck shaft angle which plays vital role in stability, control of lateral balance, walking and hip movements. The main goal was to compare the NSA in intertrochanteric fracture of femur immediately after the surgical fixation using either Dynamic Hip Screw or Proximal Femoral Nail. In the elderly among all of the hip fractures approximately half are intertrochanteric fractures and out of which approximately 50% of fractures are unstable. Method: X-ray of pelvis with both hips was taken prior to fixation and after fixation, done either with PFN or DHS and morphometric measurements were taken. Result: The mean neck shaft angle restored after fixation with PFN (131.10±7.24 degree) was almost similar to that of normal side (129.58±5.79degree) whereas it was more with DHS (141.65±9.78 degree). Conclusion: Restoration of Anatomical NSA is more achievable with PFN as compared to NSA.","PeriodicalId":14302,"journal":{"name":"International Journal of Orthopaedics Sciences","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of neck shaft angle achieved immediately after surgical fixation of intertrochanteric fracture\",\"authors\":\"Shubham Gupta, A. Bhandari\",\"doi\":\"10.22271/ortho.2023.v9.i2c.3371\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: The angle between femur neck and the long axis of shaft is known as neck shaft angle which plays vital role in stability, control of lateral balance, walking and hip movements. The main goal was to compare the NSA in intertrochanteric fracture of femur immediately after the surgical fixation using either Dynamic Hip Screw or Proximal Femoral Nail. In the elderly among all of the hip fractures approximately half are intertrochanteric fractures and out of which approximately 50% of fractures are unstable. Method: X-ray of pelvis with both hips was taken prior to fixation and after fixation, done either with PFN or DHS and morphometric measurements were taken. Result: The mean neck shaft angle restored after fixation with PFN (131.10±7.24 degree) was almost similar to that of normal side (129.58±5.79degree) whereas it was more with DHS (141.65±9.78 degree). Conclusion: Restoration of Anatomical NSA is more achievable with PFN as compared to NSA.\",\"PeriodicalId\":14302,\"journal\":{\"name\":\"International Journal of Orthopaedics Sciences\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Orthopaedics Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22271/ortho.2023.v9.i2c.3371\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Orthopaedics Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22271/ortho.2023.v9.i2c.3371","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:股骨颈与股骨长轴之间的角度被称为颈轴角,它在稳定、控制侧平衡、行走和髋部运动中起着至关重要的作用。主要目的是比较动态髋螺钉或股骨近端钉手术固定后立即发生股骨粗隆间骨折的NSA。在老年人髋部骨折中,约一半为粗隆间骨折,其中约50%为不稳定骨折。方法:固定前和固定后分别用PFN或DHS对骨盆和双髋进行x线透视,并进行形态测量。结果:PFN固定后恢复的颈轴角平均值(131.10±7.24度)与正常侧(129.58±5.79度)基本一致,而DHS固定后恢复的颈轴角平均值(141.65±9.78度)高于正常侧(131.10±7.24度)。结论:与NSA相比,PFN修复解剖学上的NSA更容易实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of neck shaft angle achieved immediately after surgical fixation of intertrochanteric fracture
Background: The angle between femur neck and the long axis of shaft is known as neck shaft angle which plays vital role in stability, control of lateral balance, walking and hip movements. The main goal was to compare the NSA in intertrochanteric fracture of femur immediately after the surgical fixation using either Dynamic Hip Screw or Proximal Femoral Nail. In the elderly among all of the hip fractures approximately half are intertrochanteric fractures and out of which approximately 50% of fractures are unstable. Method: X-ray of pelvis with both hips was taken prior to fixation and after fixation, done either with PFN or DHS and morphometric measurements were taken. Result: The mean neck shaft angle restored after fixation with PFN (131.10±7.24 degree) was almost similar to that of normal side (129.58±5.79degree) whereas it was more with DHS (141.65±9.78 degree). Conclusion: Restoration of Anatomical NSA is more achievable with PFN as compared to NSA.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信