{"title":"内窥镜内嵌螺旋天线","authors":"Anila P. George, M. Sujatha","doi":"10.1109/ICICES.2014.7034105","DOIUrl":null,"url":null,"abstract":"This paper analyses the characteristics of dual spiral antenna with varying length. This antenna is operated in the lower band of the radio frequency range, since human body absorbs the microwave signals. Here the concept of multilayer substrate is used in order to reduce the size of the antenna. The existing system has several limitations. Firstly, most capsules are powered by an internal battery cell that restricts capsule miniaturization. Secondly, current systems are incapable of maintaining a continuous communication link due to the random orientations of the capsule. Therefore an efficient communication link between the in-body capsule and the external receiver unit is important for the development and applicability of the Wireless Capsule Endoscopy (WCE). These limitations are overcome by this proposed antenna. Since the proposed antenna provides an omnidirectional radiation pattern and ultra wide bandwidth for short distance communication between transmitting and the receiving antenna with low power consumption. By combining two spiral antennas with different radius of the radiation zone, the Standing Wave Ratio (SWR) can be kept low for a large bandwidth, resulting in an improved spiral antenna performance.","PeriodicalId":13713,"journal":{"name":"International Conference on Information Communication and Embedded Systems (ICICES2014)","volume":"1 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2014-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Imbedded spiral antenna for endoscope\",\"authors\":\"Anila P. George, M. Sujatha\",\"doi\":\"10.1109/ICICES.2014.7034105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper analyses the characteristics of dual spiral antenna with varying length. This antenna is operated in the lower band of the radio frequency range, since human body absorbs the microwave signals. Here the concept of multilayer substrate is used in order to reduce the size of the antenna. The existing system has several limitations. Firstly, most capsules are powered by an internal battery cell that restricts capsule miniaturization. Secondly, current systems are incapable of maintaining a continuous communication link due to the random orientations of the capsule. Therefore an efficient communication link between the in-body capsule and the external receiver unit is important for the development and applicability of the Wireless Capsule Endoscopy (WCE). These limitations are overcome by this proposed antenna. Since the proposed antenna provides an omnidirectional radiation pattern and ultra wide bandwidth for short distance communication between transmitting and the receiving antenna with low power consumption. By combining two spiral antennas with different radius of the radiation zone, the Standing Wave Ratio (SWR) can be kept low for a large bandwidth, resulting in an improved spiral antenna performance.\",\"PeriodicalId\":13713,\"journal\":{\"name\":\"International Conference on Information Communication and Embedded Systems (ICICES2014)\",\"volume\":\"1 1\",\"pages\":\"1-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Conference on Information Communication and Embedded Systems (ICICES2014)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICICES.2014.7034105\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Information Communication and Embedded Systems (ICICES2014)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICES.2014.7034105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文分析了变长双螺旋天线的特性。由于人体对微波信号的吸收,该天线工作在射频范围的较低频段。这里使用多层基板的概念是为了减小天线的尺寸。现有的系统有几个限制。首先,大多数胶囊都是由内部电池供电,这限制了胶囊的小型化。其次,由于胶囊的随机方向,目前的系统无法保持连续的通信链路。因此,在体内胶囊和外部接收器单元之间建立有效的通信链路对于无线胶囊内窥镜(WCE)的发展和应用至关重要。这种天线克服了这些限制。由于所提出的天线提供了全向辐射方向图和超宽带宽,用于发射和接收天线之间的短距离通信,且功耗低。通过组合两个辐射区半径不同的螺旋天线,可以在大带宽下保持低驻波比,从而提高螺旋天线的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Imbedded spiral antenna for endoscope
This paper analyses the characteristics of dual spiral antenna with varying length. This antenna is operated in the lower band of the radio frequency range, since human body absorbs the microwave signals. Here the concept of multilayer substrate is used in order to reduce the size of the antenna. The existing system has several limitations. Firstly, most capsules are powered by an internal battery cell that restricts capsule miniaturization. Secondly, current systems are incapable of maintaining a continuous communication link due to the random orientations of the capsule. Therefore an efficient communication link between the in-body capsule and the external receiver unit is important for the development and applicability of the Wireless Capsule Endoscopy (WCE). These limitations are overcome by this proposed antenna. Since the proposed antenna provides an omnidirectional radiation pattern and ultra wide bandwidth for short distance communication between transmitting and the receiving antenna with low power consumption. By combining two spiral antennas with different radius of the radiation zone, the Standing Wave Ratio (SWR) can be kept low for a large bandwidth, resulting in an improved spiral antenna performance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信