电检测极低含量的转铁蛋白,以表征铁代谢

A. Girard, O. de Sagazan, F. le Bihan, T. Mohammed‐Brahim, F. Geneste, P. Brissot, C. Guguen-Guillouzo
{"title":"电检测极低含量的转铁蛋白,以表征铁代谢","authors":"A. Girard, O. de Sagazan, F. le Bihan, T. Mohammed‐Brahim, F. Geneste, P. Brissot, C. Guguen-Guillouzo","doi":"10.1109/ICSENST.2008.4757183","DOIUrl":null,"url":null,"abstract":"Suspended-gate FETs, namely SGFET, with sub-micron gap are used to detect electrically transferrin concentration directly without any labelling. The fabrication of the device and the process to functionnalize it, so that it will be able to detect transferrin, are given. The feasibility of the detection is demonstrated and a range of detectable concentrations is determined. Concentration, as low as 100 ng/mL, is measured. The maximum concentration in the linear regime, 5 mug/mL, is under the range of the standard clinical techniques. The fabrication of the device is compatible with usual microelectronic tools. Its functionalization can be easily implemented in any chemical environment. Present results open the way to simultaneous detection of many proteins giving in real time indication on complicated biologic functions as liver metabolism.","PeriodicalId":6299,"journal":{"name":"2008 3rd International Conference on Sensing Technology","volume":"4 1","pages":"637-641"},"PeriodicalIF":0.0000,"publicationDate":"2008-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Electrical detection of very low content of transferrin in view of iron metabolism characterization\",\"authors\":\"A. Girard, O. de Sagazan, F. le Bihan, T. Mohammed‐Brahim, F. Geneste, P. Brissot, C. Guguen-Guillouzo\",\"doi\":\"10.1109/ICSENST.2008.4757183\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Suspended-gate FETs, namely SGFET, with sub-micron gap are used to detect electrically transferrin concentration directly without any labelling. The fabrication of the device and the process to functionnalize it, so that it will be able to detect transferrin, are given. The feasibility of the detection is demonstrated and a range of detectable concentrations is determined. Concentration, as low as 100 ng/mL, is measured. The maximum concentration in the linear regime, 5 mug/mL, is under the range of the standard clinical techniques. The fabrication of the device is compatible with usual microelectronic tools. Its functionalization can be easily implemented in any chemical environment. Present results open the way to simultaneous detection of many proteins giving in real time indication on complicated biologic functions as liver metabolism.\",\"PeriodicalId\":6299,\"journal\":{\"name\":\"2008 3rd International Conference on Sensing Technology\",\"volume\":\"4 1\",\"pages\":\"637-641\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 3rd International Conference on Sensing Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENST.2008.4757183\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 3rd International Conference on Sensing Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENST.2008.4757183","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

悬浮栅fet,即SGFET,具有亚微米间隙,用于直接检测电转铁蛋白浓度,而无需任何标记。给出了该装置的制作方法和使其功能化的过程,使其能够检测转铁蛋白。证明了检测的可行性,并确定了可检测浓度的范围。浓度低至100 ng/mL。线性方案的最大浓度为5马克杯/毫升,在标准临床技术的范围内。该装置的制造与通常的微电子工具兼容。它的功能化可以很容易地在任何化学环境中实现。目前的研究结果为同时检测多种蛋白质提供肝脏代谢等复杂生物功能的实时指示开辟了道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrical detection of very low content of transferrin in view of iron metabolism characterization
Suspended-gate FETs, namely SGFET, with sub-micron gap are used to detect electrically transferrin concentration directly without any labelling. The fabrication of the device and the process to functionnalize it, so that it will be able to detect transferrin, are given. The feasibility of the detection is demonstrated and a range of detectable concentrations is determined. Concentration, as low as 100 ng/mL, is measured. The maximum concentration in the linear regime, 5 mug/mL, is under the range of the standard clinical techniques. The fabrication of the device is compatible with usual microelectronic tools. Its functionalization can be easily implemented in any chemical environment. Present results open the way to simultaneous detection of many proteins giving in real time indication on complicated biologic functions as liver metabolism.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信