自动选择跨轴的心肌SPECT断层图重新定位

A. Ezekiel, G. Germano, K. V. Van Train, H. Kiat, D. Berman
{"title":"自动选择跨轴的心肌SPECT断层图重新定位","authors":"A. Ezekiel, G. Germano, K. V. Van Train, H. Kiat, D. Berman","doi":"10.1109/CIC.1993.378318","DOIUrl":null,"url":null,"abstract":"Reorientation of transaxial SPECT myocardial tomograms into short and vertical long axis tomograms currently requires manual selection of the transaxial reference plane and manual determination of the left ventricle's long axis orientation in that plane. To reduce the time required for this procedure and promote objectivity, an algorithm was developed to automatically determine these parameters, using an approach that models the transaxial section of the myocardium as an ellipse. Automatically determined values for the reference plane and the long axis orientation in 14 normal and 11 abnormal patients in dual isotope, Tl-201 rest and Tc-Sestamibi stress, were compared with those obtained manually, with good correlation (r=0.91, p<0.001 for the axis orientation). The algorithm may eventually allow completely automatic reorientation of myocardial SPECT studies, thereby reducing operator labor and subjectivity.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"38 1","pages":"651-654"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Automatic selection of transaxial axis for reorientation of myocardial SPECT tomograms\",\"authors\":\"A. Ezekiel, G. Germano, K. V. Van Train, H. Kiat, D. Berman\",\"doi\":\"10.1109/CIC.1993.378318\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reorientation of transaxial SPECT myocardial tomograms into short and vertical long axis tomograms currently requires manual selection of the transaxial reference plane and manual determination of the left ventricle's long axis orientation in that plane. To reduce the time required for this procedure and promote objectivity, an algorithm was developed to automatically determine these parameters, using an approach that models the transaxial section of the myocardium as an ellipse. Automatically determined values for the reference plane and the long axis orientation in 14 normal and 11 abnormal patients in dual isotope, Tl-201 rest and Tc-Sestamibi stress, were compared with those obtained manually, with good correlation (r=0.91, p<0.001 for the axis orientation). The algorithm may eventually allow completely automatic reorientation of myocardial SPECT studies, thereby reducing operator labor and subjectivity.<<ETX>>\",\"PeriodicalId\":20445,\"journal\":{\"name\":\"Proceedings of Computers in Cardiology Conference\",\"volume\":\"38 1\",\"pages\":\"651-654\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Computers in Cardiology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1993.378318\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378318","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目前,将经轴SPECT心肌层析成像重新定位为短轴和垂直长轴层析成像需要人工选择经轴参考平面,并人工确定左心室在该平面内的长轴方向。为了减少这一过程所需的时间并提高客观性,我们开发了一种算法来自动确定这些参数,使用一种将心肌横轴切片建模为椭圆的方法。将14例正常患者和11例异常患者的Tl-201休息和Tc-Sestamibi应激双同位素的参考平面和长轴取向自动测定值与人工测定值进行比较,相关性较好(r=0.91, p>
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Automatic selection of transaxial axis for reorientation of myocardial SPECT tomograms
Reorientation of transaxial SPECT myocardial tomograms into short and vertical long axis tomograms currently requires manual selection of the transaxial reference plane and manual determination of the left ventricle's long axis orientation in that plane. To reduce the time required for this procedure and promote objectivity, an algorithm was developed to automatically determine these parameters, using an approach that models the transaxial section of the myocardium as an ellipse. Automatically determined values for the reference plane and the long axis orientation in 14 normal and 11 abnormal patients in dual isotope, Tl-201 rest and Tc-Sestamibi stress, were compared with those obtained manually, with good correlation (r=0.91, p<0.001 for the axis orientation). The algorithm may eventually allow completely automatic reorientation of myocardial SPECT studies, thereby reducing operator labor and subjectivity.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信