A. Hoshino, T. Takeda, M. Akiba, T. Kazama, Y. Watanabe, T. Yuasa, K. Hyodo, A. Uchida, T. Akatsuka, Y. Itai
{"title":"闪烁- ccd系统相干散射计算机断层扫描","authors":"A. Hoshino, T. Takeda, M. Akiba, T. Kazama, Y. Watanabe, T. Yuasa, K. Hyodo, A. Uchida, T. Akatsuka, Y. Itai","doi":"10.1109/IEMBS.1996.651947","DOIUrl":null,"url":null,"abstract":"A preliminary experiment has executed using a highly sensitive HPGe detector with spectral resolution, and it demonstrated that the subtraction of two images obtained from different scatter angles yielded a specific material distribution. To get a more exact image, a new system is designed with a scintillator-CCD detector which can correct the attenuation of incident and scattered beams by transmission CT obtained simultaneously. The proposed system can detect wide angle coherent scattered and transmitted X-rays with high spatial resolution by the same detector.","PeriodicalId":20427,"journal":{"name":"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1996-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A coherent scatter computed tomography with scintillator-CCD system\",\"authors\":\"A. Hoshino, T. Takeda, M. Akiba, T. Kazama, Y. Watanabe, T. Yuasa, K. Hyodo, A. Uchida, T. Akatsuka, Y. Itai\",\"doi\":\"10.1109/IEMBS.1996.651947\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A preliminary experiment has executed using a highly sensitive HPGe detector with spectral resolution, and it demonstrated that the subtraction of two images obtained from different scatter angles yielded a specific material distribution. To get a more exact image, a new system is designed with a scintillator-CCD detector which can correct the attenuation of incident and scattered beams by transmission CT obtained simultaneously. The proposed system can detect wide angle coherent scattered and transmitted X-rays with high spatial resolution by the same detector.\",\"PeriodicalId\":20427,\"journal\":{\"name\":\"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IEMBS.1996.651947\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1996.651947","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A coherent scatter computed tomography with scintillator-CCD system
A preliminary experiment has executed using a highly sensitive HPGe detector with spectral resolution, and it demonstrated that the subtraction of two images obtained from different scatter angles yielded a specific material distribution. To get a more exact image, a new system is designed with a scintillator-CCD detector which can correct the attenuation of incident and scattered beams by transmission CT obtained simultaneously. The proposed system can detect wide angle coherent scattered and transmitted X-rays with high spatial resolution by the same detector.