通过优化控制分布式发电机组来解决闪变噪声源问题

Yu. N. Bulatov, A. Kryukov, K. Suslov
{"title":"通过优化控制分布式发电机组来解决闪变噪声源问题","authors":"Yu. N. Bulatov, A. Kryukov, K. Suslov","doi":"10.1109/ICHQP.2018.8378834","DOIUrl":null,"url":null,"abstract":"Modern power systems shall meet the requirements of efficiency, survivability, reliability of power supply for consumers. The requirements, which become more rigid under conditions of the competitive power supply market, shall be solved by introduction of Smart Grid technologies. Smart Grid technologies stipulate wide use of distributed generation units. Distributed generation can cause fluctuation of voltage and frequency leading to the flicker noise, which is the visual perception instability. The article presents results of mode modeling of distributed generation units implemented on the basis of synchronous generators. Obtained results show that, when a load in grids with uncontrolled regulators is switched off/on, flicker noise caused by voltage/ frequency fluctuations occurs. Unmatched tuning of excitation/ frequency regulators of distributed generation unit synchronous generators can cause the same effect. Modeling results show that elimination of flicker noise is possible through using matched tuning of these regulators.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"17 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":"{\"title\":\"Solving the flicker noise origin problem by optimally controlled units of distributed generation\",\"authors\":\"Yu. N. Bulatov, A. Kryukov, K. Suslov\",\"doi\":\"10.1109/ICHQP.2018.8378834\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Modern power systems shall meet the requirements of efficiency, survivability, reliability of power supply for consumers. The requirements, which become more rigid under conditions of the competitive power supply market, shall be solved by introduction of Smart Grid technologies. Smart Grid technologies stipulate wide use of distributed generation units. Distributed generation can cause fluctuation of voltage and frequency leading to the flicker noise, which is the visual perception instability. The article presents results of mode modeling of distributed generation units implemented on the basis of synchronous generators. Obtained results show that, when a load in grids with uncontrolled regulators is switched off/on, flicker noise caused by voltage/ frequency fluctuations occurs. Unmatched tuning of excitation/ frequency regulators of distributed generation unit synchronous generators can cause the same effect. Modeling results show that elimination of flicker noise is possible through using matched tuning of these regulators.\",\"PeriodicalId\":6506,\"journal\":{\"name\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"volume\":\"17 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2018.8378834\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2018.8378834","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

现代电力系统应满足用户对供电效率、生存能力和可靠性的要求。在竞争激烈的供电市场条件下,这些要求变得更加严格,需要通过引入智能电网技术来解决。智能电网技术规定了分布式发电机组的广泛使用。分布式电源会引起电压和频率的波动,从而产生闪烁噪声,即视觉不稳定。本文介绍了在同步发电机的基础上实现分布式发电机组模式建模的结果。研究结果表明,当负载在无控稳压器电网中断开/接通时,会产生电压/频率波动引起的闪烁噪声。分布式发电机组同步发电机励磁调频不匹配调谐也会产生同样的效果。模拟结果表明,通过对这些调节器进行匹配调谐,可以消除闪烁噪声。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Solving the flicker noise origin problem by optimally controlled units of distributed generation
Modern power systems shall meet the requirements of efficiency, survivability, reliability of power supply for consumers. The requirements, which become more rigid under conditions of the competitive power supply market, shall be solved by introduction of Smart Grid technologies. Smart Grid technologies stipulate wide use of distributed generation units. Distributed generation can cause fluctuation of voltage and frequency leading to the flicker noise, which is the visual perception instability. The article presents results of mode modeling of distributed generation units implemented on the basis of synchronous generators. Obtained results show that, when a load in grids with uncontrolled regulators is switched off/on, flicker noise caused by voltage/ frequency fluctuations occurs. Unmatched tuning of excitation/ frequency regulators of distributed generation unit synchronous generators can cause the same effect. Modeling results show that elimination of flicker noise is possible through using matched tuning of these regulators.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信