与NTSC-F1的TAI比较

Dandan Liu, Jun Ruan, Sichen Fan, Hui Zhang, Yong Guan, Xinliang Wang, Junru Shi, Yan Yang, Yang Bai, Shougang Zhang
{"title":"与NTSC-F1的TAI比较","authors":"Dandan Liu, Jun Ruan, Sichen Fan, Hui Zhang, Yong Guan, Xinliang Wang, Junru Shi, Yan Yang, Yang Bai, Shougang Zhang","doi":"10.1109/IFCS-ISAF41089.2020.9234924","DOIUrl":null,"url":null,"abstract":"Frequency measurement and comparison with TAI of NTSC-F1 is presented in the paper. Automatical evaluation system of cesium fountain clock is designed to correct the systematic frequency biases in real time. The estimation of the average frequency between H-maser donated as 296 in Circular T report and NTSC-F1 is obtained over the frequency data after correcting all the shifts. Then the frequency offset between NTSC-F1 and TAI is given with the uncertainty of $2.9\\times 10^{-15}$ including the uncertainty between UTC and UTC(NTSC).","PeriodicalId":6872,"journal":{"name":"2020 Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF)","volume":"49 1","pages":"1-2"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparison with TAI of NTSC-F1\",\"authors\":\"Dandan Liu, Jun Ruan, Sichen Fan, Hui Zhang, Yong Guan, Xinliang Wang, Junru Shi, Yan Yang, Yang Bai, Shougang Zhang\",\"doi\":\"10.1109/IFCS-ISAF41089.2020.9234924\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Frequency measurement and comparison with TAI of NTSC-F1 is presented in the paper. Automatical evaluation system of cesium fountain clock is designed to correct the systematic frequency biases in real time. The estimation of the average frequency between H-maser donated as 296 in Circular T report and NTSC-F1 is obtained over the frequency data after correcting all the shifts. Then the frequency offset between NTSC-F1 and TAI is given with the uncertainty of $2.9\\\\times 10^{-15}$ including the uncertainty between UTC and UTC(NTSC).\",\"PeriodicalId\":6872,\"journal\":{\"name\":\"2020 Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF)\",\"volume\":\"49 1\",\"pages\":\"1-2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IFCS-ISAF41089.2020.9234924\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IFCS-ISAF41089.2020.9234924","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了NTSC-F1的频率测量及与TAI的比较。设计了铯喷泉钟自动评估系统,实时校正系统的频率偏差。对所有移位校正后的频率数据得到了Circular T报告中捐赠的H-maser 296与NTSC-F1之间的平均频率估计值。然后给出了NTSC- f1与TAI之间的频率偏移,不确定度为$2.9\乘以10^{-15}$,其中包括UTC与UTC(NTSC)之间的不确定度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparison with TAI of NTSC-F1
Frequency measurement and comparison with TAI of NTSC-F1 is presented in the paper. Automatical evaluation system of cesium fountain clock is designed to correct the systematic frequency biases in real time. The estimation of the average frequency between H-maser donated as 296 in Circular T report and NTSC-F1 is obtained over the frequency data after correcting all the shifts. Then the frequency offset between NTSC-F1 and TAI is given with the uncertainty of $2.9\times 10^{-15}$ including the uncertainty between UTC and UTC(NTSC).
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信