一种预应力混凝土构件通道质量检测新方法的仿真研究

Jiang Yin-jun, Zhu Yong-hua
{"title":"一种预应力混凝土构件通道质量检测新方法的仿真研究","authors":"Jiang Yin-jun, Zhu Yong-hua","doi":"10.1109/ICETCE.2011.5775867","DOIUrl":null,"url":null,"abstract":"Due to lack of effective detection method, channel quality accidents of post-tensioned concrete construction cannot to be discovered on time. An infrared detection principle based on electric heating is intended to be put forward to solve the above-mentioned problem. The results of the numeric simulation on the temperature field of a prestressed concrete component indicate that the electric heating infrared detection technology, for its energy consumption, efficiency and safety, is feasible for detecting the channel quality of prestressed concrete component, but the electric current needs to be controlled to avoid high temperature which affects the physical and mechanical properties of the strand and the concrete.","PeriodicalId":6340,"journal":{"name":"2011 International Conference on Electric Technology and Civil Engineering (ICETCE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-04-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulation of a new approach of prestressed concrete component channel quality test\",\"authors\":\"Jiang Yin-jun, Zhu Yong-hua\",\"doi\":\"10.1109/ICETCE.2011.5775867\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Due to lack of effective detection method, channel quality accidents of post-tensioned concrete construction cannot to be discovered on time. An infrared detection principle based on electric heating is intended to be put forward to solve the above-mentioned problem. The results of the numeric simulation on the temperature field of a prestressed concrete component indicate that the electric heating infrared detection technology, for its energy consumption, efficiency and safety, is feasible for detecting the channel quality of prestressed concrete component, but the electric current needs to be controlled to avoid high temperature which affects the physical and mechanical properties of the strand and the concrete.\",\"PeriodicalId\":6340,\"journal\":{\"name\":\"2011 International Conference on Electric Technology and Civil Engineering (ICETCE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-04-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2011 International Conference on Electric Technology and Civil Engineering (ICETCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICETCE.2011.5775867\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2011 International Conference on Electric Technology and Civil Engineering (ICETCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICETCE.2011.5775867","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

由于缺乏有效的检测手段,后张混凝土施工渠道质量事故不能及时发现。针对上述问题,拟提出一种基于电加热的红外探测原理。对某预应力混凝土构件温度场的数值模拟结果表明,电加热红外检测技术对预应力混凝土构件的通道质量检测具有节能、高效、安全等优点,是可行的,但需要控制电流,避免温度过高影响钢绞线和混凝土的物理力学性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simulation of a new approach of prestressed concrete component channel quality test
Due to lack of effective detection method, channel quality accidents of post-tensioned concrete construction cannot to be discovered on time. An infrared detection principle based on electric heating is intended to be put forward to solve the above-mentioned problem. The results of the numeric simulation on the temperature field of a prestressed concrete component indicate that the electric heating infrared detection technology, for its energy consumption, efficiency and safety, is feasible for detecting the channel quality of prestressed concrete component, but the electric current needs to be controlled to avoid high temperature which affects the physical and mechanical properties of the strand and the concrete.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信