I. Kravets, O. I. Bashynskiy, A. Kushnir, O. Shapovalov
{"title":"发电设备的火灾危险因素","authors":"I. Kravets, O. I. Bashynskiy, A. Kushnir, O. Shapovalov","doi":"10.32447/20786662.34.2019.07","DOIUrl":null,"url":null,"abstract":"The article deals with the problems of fire hazard of electricity-generating equipment during their exploitation. Intensive electrification of industrial and residual objects leads to the saturation of these objects with different electricity-generating equipment. Functioning of such equipment is accompanied with high heat emission and contains significant fire hazard. The electric current in an electrical conductor produces heat, when electric energy turns into thermal. All electrical equipment must be produced in strict adherence to fire safety rules and requirements. Ignoring these requirements causes heating of conductors through all the length, spunking of isolation, sparkling and, as a result, breaking-out of fire. Therefore, reducing the probability of fire even in the cases of abnormal work, wrong exploitation and foreseen refuses is the main task during planning and exploitation of electrical equipment and also during selection of structural materials. The primary purpose of fire prevention measures in the electrical equipment is avoiding of its self-ignition, and localization of fire after the self-ignition of electricity-generating equipment. Fire safety during exploitation of electricity-generating equipment depends on its technical state. Correct choice of conductor cross section is very important. Protection stage of electrical equipment, type of wiring, and cable laying method must comply with environmental conditions and have the proper climatic implementation and placement category. Proper protective devices from a short circuit and overloads must be used. Their operating values must be also foreseen. All above-mentioned measures prevent fires and explosions during exploitation of electrical equipment. Key","PeriodicalId":12280,"journal":{"name":"Fire Safety","volume":"85 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"FACTORS OF FIRE HAZARD OF ELECTRICITY-GENERATING EQUIPMENT\",\"authors\":\"I. Kravets, O. I. Bashynskiy, A. Kushnir, O. Shapovalov\",\"doi\":\"10.32447/20786662.34.2019.07\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article deals with the problems of fire hazard of electricity-generating equipment during their exploitation. Intensive electrification of industrial and residual objects leads to the saturation of these objects with different electricity-generating equipment. Functioning of such equipment is accompanied with high heat emission and contains significant fire hazard. The electric current in an electrical conductor produces heat, when electric energy turns into thermal. All electrical equipment must be produced in strict adherence to fire safety rules and requirements. Ignoring these requirements causes heating of conductors through all the length, spunking of isolation, sparkling and, as a result, breaking-out of fire. Therefore, reducing the probability of fire even in the cases of abnormal work, wrong exploitation and foreseen refuses is the main task during planning and exploitation of electrical equipment and also during selection of structural materials. The primary purpose of fire prevention measures in the electrical equipment is avoiding of its self-ignition, and localization of fire after the self-ignition of electricity-generating equipment. Fire safety during exploitation of electricity-generating equipment depends on its technical state. Correct choice of conductor cross section is very important. Protection stage of electrical equipment, type of wiring, and cable laying method must comply with environmental conditions and have the proper climatic implementation and placement category. Proper protective devices from a short circuit and overloads must be used. Their operating values must be also foreseen. All above-mentioned measures prevent fires and explosions during exploitation of electrical equipment. Key\",\"PeriodicalId\":12280,\"journal\":{\"name\":\"Fire Safety\",\"volume\":\"85 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-07-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Safety\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.32447/20786662.34.2019.07\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Safety","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32447/20786662.34.2019.07","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
FACTORS OF FIRE HAZARD OF ELECTRICITY-GENERATING EQUIPMENT
The article deals with the problems of fire hazard of electricity-generating equipment during their exploitation. Intensive electrification of industrial and residual objects leads to the saturation of these objects with different electricity-generating equipment. Functioning of such equipment is accompanied with high heat emission and contains significant fire hazard. The electric current in an electrical conductor produces heat, when electric energy turns into thermal. All electrical equipment must be produced in strict adherence to fire safety rules and requirements. Ignoring these requirements causes heating of conductors through all the length, spunking of isolation, sparkling and, as a result, breaking-out of fire. Therefore, reducing the probability of fire even in the cases of abnormal work, wrong exploitation and foreseen refuses is the main task during planning and exploitation of electrical equipment and also during selection of structural materials. The primary purpose of fire prevention measures in the electrical equipment is avoiding of its self-ignition, and localization of fire after the self-ignition of electricity-generating equipment. Fire safety during exploitation of electricity-generating equipment depends on its technical state. Correct choice of conductor cross section is very important. Protection stage of electrical equipment, type of wiring, and cable laying method must comply with environmental conditions and have the proper climatic implementation and placement category. Proper protective devices from a short circuit and overloads must be used. Their operating values must be also foreseen. All above-mentioned measures prevent fires and explosions during exploitation of electrical equipment. Key