{"title":"用于固体核磁共振应用的大体积高b1均匀性线圈设计","authors":"A.F. Privalov ,&nbsp;S.V. Dvinskikh ,&nbsp;H.-M. Vieth","doi":"10.1006/jmra.1996.0229","DOIUrl":null,"url":null,"abstract":"<div><p>The design of a solenoidal NMR coil with high-<em>B</em><sub>1</sub>homogeneity for high-frequency solid-state NMR is described. The coil is made of thin ribbon of continuously variable width. The width is varied to minimize inhomogeneity in the axial direction. The field distribution throughout the entire volume of the sample was taken into account. The gap between turns is constant and kept small to minimize field inhomogeneity in the radial direction. For large samples in particular, coils of this design tested at 300 MHz show significantly better homogeneity than helical coils with constant pitch or coils with variable pitch but fixed ribbon width.</p></div>","PeriodicalId":16165,"journal":{"name":"Journal of Magnetic Resonance, Series A","volume":"123 2","pages":"Pages 157-160"},"PeriodicalIF":0.0000,"publicationDate":"1996-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1006/jmra.1996.0229","citationCount":"24","resultStr":"{\"title\":\"Coil Design for Large-Volume High-B1Homogeneity for Solid-State NMR Applications\",\"authors\":\"A.F. Privalov ,&nbsp;S.V. Dvinskikh ,&nbsp;H.-M. Vieth\",\"doi\":\"10.1006/jmra.1996.0229\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The design of a solenoidal NMR coil with high-<em>B</em><sub>1</sub>homogeneity for high-frequency solid-state NMR is described. The coil is made of thin ribbon of continuously variable width. The width is varied to minimize inhomogeneity in the axial direction. The field distribution throughout the entire volume of the sample was taken into account. The gap between turns is constant and kept small to minimize field inhomogeneity in the radial direction. For large samples in particular, coils of this design tested at 300 MHz show significantly better homogeneity than helical coils with constant pitch or coils with variable pitch but fixed ribbon width.</p></div>\",\"PeriodicalId\":16165,\"journal\":{\"name\":\"Journal of Magnetic Resonance, Series A\",\"volume\":\"123 2\",\"pages\":\"Pages 157-160\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1006/jmra.1996.0229\",\"citationCount\":\"24\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Magnetic Resonance, Series A\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1064185896902296\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Magnetic Resonance, Series A","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1064185896902296","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 24

摘要

介绍了一种用于高频固态核磁共振的高硼均匀性螺线形核磁共振线圈的设计。线圈由宽度连续可变的薄带制成。宽度的变化是为了尽量减少轴向的不均匀性。考虑了整个样品体积的场分布。匝间的间隙保持恒定并保持较小,以尽量减少径向上的场不均匀性。特别是对于大样本,这种设计的线圈在300 MHz下测试的均匀性明显优于恒定螺距的螺旋线圈或变螺距但固定带宽的线圈。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Coil Design for Large-Volume High-B1Homogeneity for Solid-State NMR Applications

The design of a solenoidal NMR coil with high-B1homogeneity for high-frequency solid-state NMR is described. The coil is made of thin ribbon of continuously variable width. The width is varied to minimize inhomogeneity in the axial direction. The field distribution throughout the entire volume of the sample was taken into account. The gap between turns is constant and kept small to minimize field inhomogeneity in the radial direction. For large samples in particular, coils of this design tested at 300 MHz show significantly better homogeneity than helical coils with constant pitch or coils with variable pitch but fixed ribbon width.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信