{"title":"回波平面成像中的噪声特征。","authors":"T. Miyati, T. Banno, H. Fujita, M. Mase, H. Narita, M. Imazawa, S. Sanada, K. Koshida, T. Kasuga","doi":"10.1163/156855700750265503","DOIUrl":null,"url":null,"abstract":"Characteristics of the acoustic noise generated by magnetic resonance imagers of different systems and performance levels were studied when operating in echo-planar imaging (EPI) sequence. Continuous equivalent A-weighted sound pressure levels (Leq) and peak impulse sound pressure levels (Lpeak) during EPI were measured in 12 clinical super-conducting MRI systems (0.5-1.5 T). Sound pressure levels and frequency spectra of EPI were compared with those of nine different pulse sequences. EPI sound pressure levels differed among institutions (Leq = 94.2 +/- 2.7 dBA. Lpeak = 109.1 +/- 3.5 dB), but these were within permissible noise exposure levels. Sound pressure levels during EPI were not significantly different from those during other pulse sequences. However, compared to other pulse sequences. EPI had a significantly greater proportion of acoustic noise in the high octave-frequency band. Single-shot EPI had relatively higher frequency noise and greater Leq than multishot EPI, but the difference in Leq decreased when the number of slices in multishot EPI was increased.","PeriodicalId":77139,"journal":{"name":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","volume":"83 1","pages":"345-56"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Characteristics of acoustic noise in echo-planar imaging.\",\"authors\":\"T. Miyati, T. Banno, H. Fujita, M. Mase, H. Narita, M. Imazawa, S. Sanada, K. Koshida, T. Kasuga\",\"doi\":\"10.1163/156855700750265503\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Characteristics of the acoustic noise generated by magnetic resonance imagers of different systems and performance levels were studied when operating in echo-planar imaging (EPI) sequence. Continuous equivalent A-weighted sound pressure levels (Leq) and peak impulse sound pressure levels (Lpeak) during EPI were measured in 12 clinical super-conducting MRI systems (0.5-1.5 T). Sound pressure levels and frequency spectra of EPI were compared with those of nine different pulse sequences. EPI sound pressure levels differed among institutions (Leq = 94.2 +/- 2.7 dBA. Lpeak = 109.1 +/- 3.5 dB), but these were within permissible noise exposure levels. Sound pressure levels during EPI were not significantly different from those during other pulse sequences. However, compared to other pulse sequences. EPI had a significantly greater proportion of acoustic noise in the high octave-frequency band. Single-shot EPI had relatively higher frequency noise and greater Leq than multishot EPI, but the difference in Leq decreased when the number of slices in multishot EPI was increased.\",\"PeriodicalId\":77139,\"journal\":{\"name\":\"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering\",\"volume\":\"83 1\",\"pages\":\"345-56\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1163/156855700750265503\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1163/156855700750265503","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

研究了不同系统和性能水平的磁共振成像仪在回波平面成像(EPI)序列中产生的噪声特征。在12台临床超导MRI系统(0.5 ~ 1.5 T)中测量EPI过程中的连续等效a加权声压级(Leq)和脉冲声压峰值(Lpeak),并与9种不同脉冲序列的声压级和频谱进行比较。EPI声压级各机构间存在差异(Leq = 94.2 +/- 2.7 dBA)。Lpeak = 109.1 +/- 3.5 dB),但这些都在允许的噪声暴露水平之内。EPI过程中的声压级与其他脉冲序列的声压级差异不显著。然而,与其他脉冲序列相比。EPI在高倍频频带的声学噪声比例显著增加。单次EPI比多次EPI具有更高的频率噪声和更高的Leq,但随着多次EPI切片数的增加,Leq的差异减小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Characteristics of acoustic noise in echo-planar imaging.
Characteristics of the acoustic noise generated by magnetic resonance imagers of different systems and performance levels were studied when operating in echo-planar imaging (EPI) sequence. Continuous equivalent A-weighted sound pressure levels (Leq) and peak impulse sound pressure levels (Lpeak) during EPI were measured in 12 clinical super-conducting MRI systems (0.5-1.5 T). Sound pressure levels and frequency spectra of EPI were compared with those of nine different pulse sequences. EPI sound pressure levels differed among institutions (Leq = 94.2 +/- 2.7 dBA. Lpeak = 109.1 +/- 3.5 dB), but these were within permissible noise exposure levels. Sound pressure levels during EPI were not significantly different from those during other pulse sequences. However, compared to other pulse sequences. EPI had a significantly greater proportion of acoustic noise in the high octave-frequency band. Single-shot EPI had relatively higher frequency noise and greater Leq than multishot EPI, but the difference in Leq decreased when the number of slices in multishot EPI was increased.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信