综合设备有效性在优化重症监护室和急诊科呼吸机可靠性中的应用

Q4 Biochemistry, Genetics and Molecular Biology
Khelood A. Mkalaf, Rami Hikmat Al-Hadeethi, Peter Gibson
{"title":"综合设备有效性在优化重症监护室和急诊科呼吸机可靠性中的应用","authors":"Khelood A. Mkalaf, Rami Hikmat Al-Hadeethi, Peter Gibson","doi":"10.51173/jt.v5i2.1419","DOIUrl":null,"url":null,"abstract":"Healthcare organizations seek to offer a comprehensive medical services system framework with safety and high quality. This needs continuously developing integrated governance systems that provide safe, reliable, and maintaining high-quality care and value-based care for patients. In addition to improving access to health services in time, increasing efficiencies in providing medical services, reducing the risk-based medical services, and selecting a suitable maintenance policy for maintaining the medical devices. This paper adopted a quantitative analysis method based on Reliability-Based Maintenance (RCM) to comprehensively evaluate the overall medical equipment's effectiveness. RCM is an integrated approach to continuous improvement of the maintenance programs because it can predict early medical equipment failure and determine the mean time between failures. It also assesses the risk level to the patient's life in case of a medical equipment breakdown while provisioning medical services. This study targeted biomedical engineering, intensive care units, and emergency departments at 24 public hospitals in a top 20 OECD country. It selected these departments due to the rise in the rate of patients needing ventilator equipment availability during COVID-19, risk based on the sudden breakdown of the ventilator machines, and increasing the annual budget percentage required to provide medical services, where 239 of the ventilator equipment were investigated. Staff Experience-based Evidence was adopted to collect data by interviewing staff and distributing the survey. The study found that the average OEE for ventilator devices in Intensive Care Units and Emergency Departments was 63%. The device's performance was rated at 65%, while its availability and quality rate were both rated at 100%. These findings suggest that the use of the OEE metric has improved ventilator device reliability and performance in selected hospitals. The OEE metric may have potential benefits for improving the performance of other medical devices as well.","PeriodicalId":39617,"journal":{"name":"Journal of Biomolecular Techniques","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Application of Overall Equipment Effectiveness for Optimizing Ventilator Reliability in Intensive Care Units and Emergency Departments\",\"authors\":\"Khelood A. Mkalaf, Rami Hikmat Al-Hadeethi, Peter Gibson\",\"doi\":\"10.51173/jt.v5i2.1419\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Healthcare organizations seek to offer a comprehensive medical services system framework with safety and high quality. This needs continuously developing integrated governance systems that provide safe, reliable, and maintaining high-quality care and value-based care for patients. In addition to improving access to health services in time, increasing efficiencies in providing medical services, reducing the risk-based medical services, and selecting a suitable maintenance policy for maintaining the medical devices. This paper adopted a quantitative analysis method based on Reliability-Based Maintenance (RCM) to comprehensively evaluate the overall medical equipment's effectiveness. RCM is an integrated approach to continuous improvement of the maintenance programs because it can predict early medical equipment failure and determine the mean time between failures. It also assesses the risk level to the patient's life in case of a medical equipment breakdown while provisioning medical services. This study targeted biomedical engineering, intensive care units, and emergency departments at 24 public hospitals in a top 20 OECD country. It selected these departments due to the rise in the rate of patients needing ventilator equipment availability during COVID-19, risk based on the sudden breakdown of the ventilator machines, and increasing the annual budget percentage required to provide medical services, where 239 of the ventilator equipment were investigated. Staff Experience-based Evidence was adopted to collect data by interviewing staff and distributing the survey. The study found that the average OEE for ventilator devices in Intensive Care Units and Emergency Departments was 63%. The device's performance was rated at 65%, while its availability and quality rate were both rated at 100%. These findings suggest that the use of the OEE metric has improved ventilator device reliability and performance in selected hospitals. The OEE metric may have potential benefits for improving the performance of other medical devices as well.\",\"PeriodicalId\":39617,\"journal\":{\"name\":\"Journal of Biomolecular Techniques\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Biomolecular Techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.51173/jt.v5i2.1419\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Biochemistry, Genetics and Molecular Biology\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Biomolecular Techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51173/jt.v5i2.1419","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

摘要

医疗机构寻求提供安全、高质量的综合医疗服务体系框架。这需要不断发展综合治理系统,为患者提供安全、可靠和保持高质量的护理和基于价值的护理。此外,还应及时改善获得保健服务的机会,提高提供医疗服务的效率,减少基于风险的医疗服务,并选择适当的维护政策来维护医疗设备。本文采用基于可靠性维护(reliability based Maintenance, RCM)的定量分析方法,对医疗设备的整体有效性进行综合评价。RCM是一种持续改进维护计划的综合方法,因为它可以预测早期医疗设备故障并确定故障之间的平均时间。它还评估在提供医疗服务时医疗设备发生故障对患者生命的风险程度。本研究针对经合组织前20名国家的24家公立医院的生物医学工程、重症监护病房和急诊科。选择这些科室的原因是,COVID-19期间需要呼吸机设备的患者比例上升,呼吸机突然故障带来的风险,以及提供医疗服务所需的年度预算比例增加,其中调查了239台呼吸机设备。采用员工经验证据法,通过对员工进行访谈和发放调查问卷来收集数据。研究发现,重症监护病房和急诊科呼吸机设备的平均OEE为63%。该设备的性能被评为65%,而其可用性和质量率都被评为100%。这些发现表明,在选定的医院中,OEE指标的使用改善了呼吸机装置的可靠性和性能。OEE度量也可能对改善其他医疗设备的性能有潜在的好处。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Application of Overall Equipment Effectiveness for Optimizing Ventilator Reliability in Intensive Care Units and Emergency Departments
Healthcare organizations seek to offer a comprehensive medical services system framework with safety and high quality. This needs continuously developing integrated governance systems that provide safe, reliable, and maintaining high-quality care and value-based care for patients. In addition to improving access to health services in time, increasing efficiencies in providing medical services, reducing the risk-based medical services, and selecting a suitable maintenance policy for maintaining the medical devices. This paper adopted a quantitative analysis method based on Reliability-Based Maintenance (RCM) to comprehensively evaluate the overall medical equipment's effectiveness. RCM is an integrated approach to continuous improvement of the maintenance programs because it can predict early medical equipment failure and determine the mean time between failures. It also assesses the risk level to the patient's life in case of a medical equipment breakdown while provisioning medical services. This study targeted biomedical engineering, intensive care units, and emergency departments at 24 public hospitals in a top 20 OECD country. It selected these departments due to the rise in the rate of patients needing ventilator equipment availability during COVID-19, risk based on the sudden breakdown of the ventilator machines, and increasing the annual budget percentage required to provide medical services, where 239 of the ventilator equipment were investigated. Staff Experience-based Evidence was adopted to collect data by interviewing staff and distributing the survey. The study found that the average OEE for ventilator devices in Intensive Care Units and Emergency Departments was 63%. The device's performance was rated at 65%, while its availability and quality rate were both rated at 100%. These findings suggest that the use of the OEE metric has improved ventilator device reliability and performance in selected hospitals. The OEE metric may have potential benefits for improving the performance of other medical devices as well.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Biomolecular Techniques
Journal of Biomolecular Techniques Biochemistry, Genetics and Molecular Biology-Molecular Biology
CiteScore
2.50
自引率
0.00%
发文量
9
期刊介绍: The Journal of Biomolecular Techniques is a peer-reviewed publication issued five times a year by the Association of Biomolecular Resource Facilities. The Journal was established to promote the central role biotechnology plays in contemporary research activities, to disseminate information among biomolecular resource facilities, and to communicate the biotechnology research conducted by the Association’s Research Groups and members, as well as other investigators.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信