减少不锈钢在超高真空下的放气

R. Calder, G. Lewin
{"title":"减少不锈钢在超高真空下的放气","authors":"R. Calder, G. Lewin","doi":"10.1088/0508-3443/18/10/313","DOIUrl":null,"url":null,"abstract":"The outgassing rate of a 2 mm thick stainless-steel sheet was measured in ultra-high vacuum at constant pressure to avoid the readsorption occurring in a `rate of pressure rise' determination. The rate was typically 10-12 torr l. cm-2 sec-1 and about 99% or more of the gas was hydrogen. Since stainless steel usually contains large amounts of hydrogen and the diffusion coefficient of hydrogen in stainless steel is high, it was suspected that the hydrogen diffuses to the surface from the interior of the metal and is released into the vacuum. Calculations show that the observed outgassing rate could be explained by such a process and should be reduced by several orders of magnitude by a high-temperature treatment. The effects of residual hydrogen in the treatment furnace and hydrogen permeation from the atmosphere are also considered in these calculations. The greater the thickness of the metal, the higher the temperature has to be. Measurements are in reasonable agreement with these calculations.","PeriodicalId":9350,"journal":{"name":"British Journal of Applied Physics","volume":"235 1","pages":"1459-1472"},"PeriodicalIF":0.0000,"publicationDate":"1967-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"129","resultStr":"{\"title\":\"Reduction of stainless-steel outgassing in ultra-high vacuum\",\"authors\":\"R. Calder, G. Lewin\",\"doi\":\"10.1088/0508-3443/18/10/313\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The outgassing rate of a 2 mm thick stainless-steel sheet was measured in ultra-high vacuum at constant pressure to avoid the readsorption occurring in a `rate of pressure rise' determination. The rate was typically 10-12 torr l. cm-2 sec-1 and about 99% or more of the gas was hydrogen. Since stainless steel usually contains large amounts of hydrogen and the diffusion coefficient of hydrogen in stainless steel is high, it was suspected that the hydrogen diffuses to the surface from the interior of the metal and is released into the vacuum. Calculations show that the observed outgassing rate could be explained by such a process and should be reduced by several orders of magnitude by a high-temperature treatment. The effects of residual hydrogen in the treatment furnace and hydrogen permeation from the atmosphere are also considered in these calculations. The greater the thickness of the metal, the higher the temperature has to be. Measurements are in reasonable agreement with these calculations.\",\"PeriodicalId\":9350,\"journal\":{\"name\":\"British Journal of Applied Physics\",\"volume\":\"235 1\",\"pages\":\"1459-1472\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1967-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"129\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"British Journal of Applied Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/0508-3443/18/10/313\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Applied Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0508-3443/18/10/313","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 129

摘要

在超高真空和恒压条件下测量2mm厚不锈钢板的放气速率,以避免在“压力上升速率”测定中发生再吸附。速率通常为10-12 torr l. cm-2 sec-1,大约99%或更多的气体是氢气。由于不锈钢通常含有大量的氢,并且氢在不锈钢中的扩散系数很高,因此怀疑氢是从金属内部扩散到表面并释放到真空中。计算表明,观察到的放气速率可以用这种过程来解释,并且通过高温处理可以降低几个数量级。在这些计算中还考虑了处理炉内残余氢和大气中氢渗透的影响。金属的厚度越大,温度就必须越高。测量结果与这些计算结果相当吻合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Reduction of stainless-steel outgassing in ultra-high vacuum
The outgassing rate of a 2 mm thick stainless-steel sheet was measured in ultra-high vacuum at constant pressure to avoid the readsorption occurring in a `rate of pressure rise' determination. The rate was typically 10-12 torr l. cm-2 sec-1 and about 99% or more of the gas was hydrogen. Since stainless steel usually contains large amounts of hydrogen and the diffusion coefficient of hydrogen in stainless steel is high, it was suspected that the hydrogen diffuses to the surface from the interior of the metal and is released into the vacuum. Calculations show that the observed outgassing rate could be explained by such a process and should be reduced by several orders of magnitude by a high-temperature treatment. The effects of residual hydrogen in the treatment furnace and hydrogen permeation from the atmosphere are also considered in these calculations. The greater the thickness of the metal, the higher the temperature has to be. Measurements are in reasonable agreement with these calculations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信