解释RVM测量,超越极化光谱

J. van Bolhuis, E. Gulski, J. Smit, D. Pepper
{"title":"解释RVM测量,超越极化光谱","authors":"J. van Bolhuis, E. Gulski, J. Smit, D. Pepper","doi":"10.1109/ELINSL.2002.995907","DOIUrl":null,"url":null,"abstract":"Much has been said about the reliability and interpretation of recovery voltage method (RVM) measurements. It has been shown in literature that the RVM method can be used to detect local moisture ingress in transformers, but also it has been shown that the old interpretation of the 'dominant time constant' has been found wanting. An important failure of the 'dominant time constant' interpretation is that it both focusses the user on a too simple interpretation and neglects data on other quantities that have also been recorded during this measurement. This paper deals with the all quantities that are recorded during an RVM measurement and shows how to use them so that they can form the basis of a better way to interpret RVM measurements.","PeriodicalId":10532,"journal":{"name":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","volume":"57 1","pages":"179-182"},"PeriodicalIF":0.0000,"publicationDate":"2002-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Interpretation of RVM measurements, beyond the polarisation spectrum\",\"authors\":\"J. van Bolhuis, E. Gulski, J. Smit, D. Pepper\",\"doi\":\"10.1109/ELINSL.2002.995907\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Much has been said about the reliability and interpretation of recovery voltage method (RVM) measurements. It has been shown in literature that the RVM method can be used to detect local moisture ingress in transformers, but also it has been shown that the old interpretation of the 'dominant time constant' has been found wanting. An important failure of the 'dominant time constant' interpretation is that it both focusses the user on a too simple interpretation and neglects data on other quantities that have also been recorded during this measurement. This paper deals with the all quantities that are recorded during an RVM measurement and shows how to use them so that they can form the basis of a better way to interpret RVM measurements.\",\"PeriodicalId\":10532,\"journal\":{\"name\":\"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)\",\"volume\":\"57 1\",\"pages\":\"179-182\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2002.995907\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2002.995907","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

关于恢复电压法(RVM)测量的可靠性和解释已经说了很多。文献表明,RVM方法可用于检测变压器中的局部水分侵入,但也表明,“主导时间常数”的旧解释已被发现不足。“主导时间常数”解释的一个重要失败是,它既将用户集中在过于简单的解释上,又忽略了在此测量期间记录的其他数量的数据。本文讨论了在RVM测量期间记录的所有量,并展示了如何使用它们,以便它们能够形成更好地解释RVM测量的基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Interpretation of RVM measurements, beyond the polarisation spectrum
Much has been said about the reliability and interpretation of recovery voltage method (RVM) measurements. It has been shown in literature that the RVM method can be used to detect local moisture ingress in transformers, but also it has been shown that the old interpretation of the 'dominant time constant' has been found wanting. An important failure of the 'dominant time constant' interpretation is that it both focusses the user on a too simple interpretation and neglects data on other quantities that have also been recorded during this measurement. This paper deals with the all quantities that are recorded during an RVM measurement and shows how to use them so that they can form the basis of a better way to interpret RVM measurements.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信