{"title":"去铁霉制剂中遗传毒性杂质的低水平测定","authors":"Pravish Kumar Tiwari, P. Sathe, Navin Devadiga","doi":"10.4236/JASMI.2013.34023","DOIUrl":null,"url":null,"abstract":"4-hydrazinobenzoic \nacid has been highlighted as one of the potential genotoxic impurities (PGIs). \nA sensitive HPLC method was developed and validated for the determination of \n4-hydrazino benzoic acid in Deferasirox Tablet. HPLC method on Zorbax SB C18 \ncolumn (250 × 4.6 mm i.d.), 5 μm, with UV Detector was used. The proposed \nmethod was cost effective, specific, linear, accurate, rugged and precise. The \ncalibration curves showed good linearity over the concentration range of 0.5 μg/ml to 1.5 μg/ml with respect to the sample. The correlation \ncoefficient was 0.999. Excellent recoveries of 102% were obtained at the level \n0.5 μg/ml.","PeriodicalId":14932,"journal":{"name":"Journal of Analytical Sciences, Methods and Instrumentation","volume":"35 1","pages":"179-183"},"PeriodicalIF":0.0000,"publicationDate":"2013-10-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Low Level Determination of Genotoxic Impurity in Deferasirox Formulation\",\"authors\":\"Pravish Kumar Tiwari, P. Sathe, Navin Devadiga\",\"doi\":\"10.4236/JASMI.2013.34023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"4-hydrazinobenzoic \\nacid has been highlighted as one of the potential genotoxic impurities (PGIs). \\nA sensitive HPLC method was developed and validated for the determination of \\n4-hydrazino benzoic acid in Deferasirox Tablet. HPLC method on Zorbax SB C18 \\ncolumn (250 × 4.6 mm i.d.), 5 μm, with UV Detector was used. The proposed \\nmethod was cost effective, specific, linear, accurate, rugged and precise. The \\ncalibration curves showed good linearity over the concentration range of 0.5 μg/ml to 1.5 μg/ml with respect to the sample. The correlation \\ncoefficient was 0.999. Excellent recoveries of 102% were obtained at the level \\n0.5 μg/ml.\",\"PeriodicalId\":14932,\"journal\":{\"name\":\"Journal of Analytical Sciences, Methods and Instrumentation\",\"volume\":\"35 1\",\"pages\":\"179-183\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-10-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Analytical Sciences, Methods and Instrumentation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4236/JASMI.2013.34023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Sciences, Methods and Instrumentation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4236/JASMI.2013.34023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Low Level Determination of Genotoxic Impurity in Deferasirox Formulation
4-hydrazinobenzoic
acid has been highlighted as one of the potential genotoxic impurities (PGIs).
A sensitive HPLC method was developed and validated for the determination of
4-hydrazino benzoic acid in Deferasirox Tablet. HPLC method on Zorbax SB C18
column (250 × 4.6 mm i.d.), 5 μm, with UV Detector was used. The proposed
method was cost effective, specific, linear, accurate, rugged and precise. The
calibration curves showed good linearity over the concentration range of 0.5 μg/ml to 1.5 μg/ml with respect to the sample. The correlation
coefficient was 0.999. Excellent recoveries of 102% were obtained at the level
0.5 μg/ml.