{"title":"使用VMAT对脑肿瘤放疗后FFF对FF光束的剂量学影响","authors":"S. Manna, S. H. Kombathula, Sanjib Gayen, Sonal Varshney, P. Pareek","doi":"10.2478/pjmpe-2021-0023","DOIUrl":null,"url":null,"abstract":"Abstract Background: This study was conducted to assess the dosimetric impact of FFF beam plans on high-grade brain neoplasms using the VMAT technique when compared with FF beam plans. Material and Methods: Thirty patients with high-grade brain neoplasms, who had received radiotherapy using VMAT technique retrospectively were selected for this study. All the patients were planned for VMAT using 6MV_FF beam and the same plan was re-optimized using 6MV_FFF beam keeping the same dose constraint. Radiotherapy dose distribution on planning target volume (PTV) and organs at risk (OAR), target conformity index (CI), Homogeneity Index (HI), Low dose volume in the patient (V5, V10, V20, and V30), and Integral dose to the whole body in both plans were compared. Results: The PTV coverage and OAR’s showed no significant differences in dose distribution between the FFF and FF beam VMAT planning. There was a reduction of the average maximum dose in the right eye, left eye, right optic nerve, and left optic nerve using FFF beams. The reduction in average low dose volume was observed in V5, V10, V20, V30, and Mean Dose. Also, a significant reduction was observed in the integral dose to the whole body using the FFF beam. Conclusions: Using FFF beams with VMAT is doable for the treatment of high-grade brain neoplasms, and the delivery mode of the FFF beam in VMAT may yield similar results to FF beam which should be confirmed in a large scale prospective clinical trial.","PeriodicalId":53955,"journal":{"name":"Polish Journal of Medical Physics and Engineering","volume":"43 1","pages":"191 - 199"},"PeriodicalIF":0.7000,"publicationDate":"2021-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Dosimetric impact of FFF over FF beam using VMAT for brain neoplasms treated with radiotherapy\",\"authors\":\"S. Manna, S. H. Kombathula, Sanjib Gayen, Sonal Varshney, P. Pareek\",\"doi\":\"10.2478/pjmpe-2021-0023\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Background: This study was conducted to assess the dosimetric impact of FFF beam plans on high-grade brain neoplasms using the VMAT technique when compared with FF beam plans. Material and Methods: Thirty patients with high-grade brain neoplasms, who had received radiotherapy using VMAT technique retrospectively were selected for this study. All the patients were planned for VMAT using 6MV_FF beam and the same plan was re-optimized using 6MV_FFF beam keeping the same dose constraint. Radiotherapy dose distribution on planning target volume (PTV) and organs at risk (OAR), target conformity index (CI), Homogeneity Index (HI), Low dose volume in the patient (V5, V10, V20, and V30), and Integral dose to the whole body in both plans were compared. Results: The PTV coverage and OAR’s showed no significant differences in dose distribution between the FFF and FF beam VMAT planning. There was a reduction of the average maximum dose in the right eye, left eye, right optic nerve, and left optic nerve using FFF beams. The reduction in average low dose volume was observed in V5, V10, V20, V30, and Mean Dose. Also, a significant reduction was observed in the integral dose to the whole body using the FFF beam. Conclusions: Using FFF beams with VMAT is doable for the treatment of high-grade brain neoplasms, and the delivery mode of the FFF beam in VMAT may yield similar results to FF beam which should be confirmed in a large scale prospective clinical trial.\",\"PeriodicalId\":53955,\"journal\":{\"name\":\"Polish Journal of Medical Physics and Engineering\",\"volume\":\"43 1\",\"pages\":\"191 - 199\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2021-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polish Journal of Medical Physics and Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2478/pjmpe-2021-0023\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polish Journal of Medical Physics and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2478/pjmpe-2021-0023","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Dosimetric impact of FFF over FF beam using VMAT for brain neoplasms treated with radiotherapy
Abstract Background: This study was conducted to assess the dosimetric impact of FFF beam plans on high-grade brain neoplasms using the VMAT technique when compared with FF beam plans. Material and Methods: Thirty patients with high-grade brain neoplasms, who had received radiotherapy using VMAT technique retrospectively were selected for this study. All the patients were planned for VMAT using 6MV_FF beam and the same plan was re-optimized using 6MV_FFF beam keeping the same dose constraint. Radiotherapy dose distribution on planning target volume (PTV) and organs at risk (OAR), target conformity index (CI), Homogeneity Index (HI), Low dose volume in the patient (V5, V10, V20, and V30), and Integral dose to the whole body in both plans were compared. Results: The PTV coverage and OAR’s showed no significant differences in dose distribution between the FFF and FF beam VMAT planning. There was a reduction of the average maximum dose in the right eye, left eye, right optic nerve, and left optic nerve using FFF beams. The reduction in average low dose volume was observed in V5, V10, V20, V30, and Mean Dose. Also, a significant reduction was observed in the integral dose to the whole body using the FFF beam. Conclusions: Using FFF beams with VMAT is doable for the treatment of high-grade brain neoplasms, and the delivery mode of the FFF beam in VMAT may yield similar results to FF beam which should be confirmed in a large scale prospective clinical trial.
期刊介绍:
Polish Journal of Medical Physics and Engineering (PJMPE) (Online ISSN: 1898-0309; Print ISSN: 1425-4689) is an official publication of the Polish Society of Medical Physics. It is a peer-reviewed, open access scientific journal with no publication fees. The issues are published quarterly online. The Journal publishes original contribution in medical physics and biomedical engineering.