用模型阶降简法简化了自动调压器的模型辨识

S. Biradar, Sahaj Saxena, Y. V. Hote
{"title":"用模型阶降简法简化了自动调压器的模型辨识","authors":"S. Biradar, Sahaj Saxena, Y. V. Hote","doi":"10.1109/ICPACE.2015.7274985","DOIUrl":null,"url":null,"abstract":"Automatic voltage regulator (AVR) is an essential entity for power system operation. Therefore, to observe the behavior and performance of AVR, study of its modeling is necessary. Since AVR is a complex system having higher order transfer function, so it is tedious to study it. In this paper, different model reduction scheme have been discussed and implemented for this system. We have applied ten different model order reduction schemes and a descriptive study of time and frequency domain analysis has been carried out. It has been observed that although different reduced models emulate the original system but their characteristics in frequency domain vary when few specifications are taken into account, for example, gain and phase margins, notch characteristics, etc. Therefore, on the basis of requirements, system engineer has to select particular reduced model for analysis and controller synthesis.","PeriodicalId":6644,"journal":{"name":"2015 International Conference on Power and Advanced Control Engineering (ICPACE)","volume":"416 1","pages":"423-428"},"PeriodicalIF":0.0000,"publicationDate":"2015-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Simplified model identification of automatic voltage regulator using model-order reduction\",\"authors\":\"S. Biradar, Sahaj Saxena, Y. V. Hote\",\"doi\":\"10.1109/ICPACE.2015.7274985\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Automatic voltage regulator (AVR) is an essential entity for power system operation. Therefore, to observe the behavior and performance of AVR, study of its modeling is necessary. Since AVR is a complex system having higher order transfer function, so it is tedious to study it. In this paper, different model reduction scheme have been discussed and implemented for this system. We have applied ten different model order reduction schemes and a descriptive study of time and frequency domain analysis has been carried out. It has been observed that although different reduced models emulate the original system but their characteristics in frequency domain vary when few specifications are taken into account, for example, gain and phase margins, notch characteristics, etc. Therefore, on the basis of requirements, system engineer has to select particular reduced model for analysis and controller synthesis.\",\"PeriodicalId\":6644,\"journal\":{\"name\":\"2015 International Conference on Power and Advanced Control Engineering (ICPACE)\",\"volume\":\"416 1\",\"pages\":\"423-428\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Power and Advanced Control Engineering (ICPACE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICPACE.2015.7274985\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Power and Advanced Control Engineering (ICPACE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICPACE.2015.7274985","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 7

摘要

自动调压器(AVR)是电力系统运行的重要组成部分。因此,为了观察AVR的行为和性能,有必要对其建模进行研究。由于AVR是一个具有高阶传递函数的复杂系统,研究起来比较繁琐。本文针对该系统讨论并实现了不同的模型约简方案。我们应用了十种不同的模型降阶方案,并进行了时域和频域分析的描述性研究。我们观察到,虽然不同的简化模型模拟了原始系统,但当考虑到一些规格时,例如增益和相位裕度,陷波特性等,它们在频域的特性会发生变化。因此,系统工程师必须根据需求选择特定的简化模型进行分析和控制器综合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simplified model identification of automatic voltage regulator using model-order reduction
Automatic voltage regulator (AVR) is an essential entity for power system operation. Therefore, to observe the behavior and performance of AVR, study of its modeling is necessary. Since AVR is a complex system having higher order transfer function, so it is tedious to study it. In this paper, different model reduction scheme have been discussed and implemented for this system. We have applied ten different model order reduction schemes and a descriptive study of time and frequency domain analysis has been carried out. It has been observed that although different reduced models emulate the original system but their characteristics in frequency domain vary when few specifications are taken into account, for example, gain and phase margins, notch characteristics, etc. Therefore, on the basis of requirements, system engineer has to select particular reduced model for analysis and controller synthesis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信