{"title":"医疗遥测系统的心电数据简化方法。","authors":"M. Kyoso, A. Uchiyama","doi":"10.1163/156855701316922306","DOIUrl":null,"url":null,"abstract":"In current medical practice, all transmitters used for monitoring an ECG send data continuously. If transmission could be limited to only the ECG data that requires the attention of a technician, the likelihood of interference and power consumption would be reduced considerably. In this paper, we propose a new ECG telemetry system. The transmitter has a simple ECG analyzer and it only transmits data when abnormal waveforms are detected. As part of this system, we propose a simple algorithm to detect an abnormal ECG. The algorithm is composed of a baseline drift canceller (utilizing a moving average calculation), a waveform detector (using a modified second order derivative) and an ECG analyzer. In order to test the effectiveness and feasibility of the algorithm, computer simulations (with a MIT-BIH ECG database) and experiments (with microprocessor-based hardware) were performed. The results of the simulations show that the detection performance and data compression performance of the algorithm are adequate. The results of the experiment show that the algorithm even performs adequately when used with microprocessor-based hardware that is of limited size or limited power consumption.","PeriodicalId":77139,"journal":{"name":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","volume":"98 1","pages":"131-152"},"PeriodicalIF":0.0000,"publicationDate":"2001-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"ECG data reduction method for medical telemetry systems.\",\"authors\":\"M. Kyoso, A. Uchiyama\",\"doi\":\"10.1163/156855701316922306\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In current medical practice, all transmitters used for monitoring an ECG send data continuously. If transmission could be limited to only the ECG data that requires the attention of a technician, the likelihood of interference and power consumption would be reduced considerably. In this paper, we propose a new ECG telemetry system. The transmitter has a simple ECG analyzer and it only transmits data when abnormal waveforms are detected. As part of this system, we propose a simple algorithm to detect an abnormal ECG. The algorithm is composed of a baseline drift canceller (utilizing a moving average calculation), a waveform detector (using a modified second order derivative) and an ECG analyzer. In order to test the effectiveness and feasibility of the algorithm, computer simulations (with a MIT-BIH ECG database) and experiments (with microprocessor-based hardware) were performed. The results of the simulations show that the detection performance and data compression performance of the algorithm are adequate. The results of the experiment show that the algorithm even performs adequately when used with microprocessor-based hardware that is of limited size or limited power consumption.\",\"PeriodicalId\":77139,\"journal\":{\"name\":\"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering\",\"volume\":\"98 1\",\"pages\":\"131-152\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2001-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1163/156855701316922306\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers of medical and biological engineering : the international journal of the Japan Society of Medical Electronics and Biological Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1163/156855701316922306","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

在目前的医疗实践中,所有用于监测心电的发射机都连续发送数据。如果传输可以仅限于需要技术人员注意的心电数据,那么干扰和功耗的可能性将大大降低。本文提出了一种新的心电遥测系统。发射机有一个简单的心电分析仪,只有在检测到异常波形时才传输数据。作为该系统的一部分,我们提出了一种简单的检测异常心电图的算法。该算法由基线漂移消除器(利用移动平均计算)、波形检测器(使用改进的二阶导数)和心电分析仪组成。为了验证该算法的有效性和可行性,进行了计算机模拟(使用MIT-BIH心电数据库)和实验(使用基于微处理器的硬件)。仿真结果表明,该算法具有良好的检测性能和数据压缩性能。实验结果表明,该算法甚至可以在有限尺寸或有限功耗的基于微处理器的硬件上使用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ECG data reduction method for medical telemetry systems.
In current medical practice, all transmitters used for monitoring an ECG send data continuously. If transmission could be limited to only the ECG data that requires the attention of a technician, the likelihood of interference and power consumption would be reduced considerably. In this paper, we propose a new ECG telemetry system. The transmitter has a simple ECG analyzer and it only transmits data when abnormal waveforms are detected. As part of this system, we propose a simple algorithm to detect an abnormal ECG. The algorithm is composed of a baseline drift canceller (utilizing a moving average calculation), a waveform detector (using a modified second order derivative) and an ECG analyzer. In order to test the effectiveness and feasibility of the algorithm, computer simulations (with a MIT-BIH ECG database) and experiments (with microprocessor-based hardware) were performed. The results of the simulations show that the detection performance and data compression performance of the algorithm are adequate. The results of the experiment show that the algorithm even performs adequately when used with microprocessor-based hardware that is of limited size or limited power consumption.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信