{"title":"巴西骨科医生对骨合后胫骨骨干暴露骨折站立时部分负重的看法","authors":"Valéria R. G. Sella, P. Machado, Hélio Jorge Alvachian Fernandes, William R. Limonge, F. B. D. Reis, F. Faloppa","doi":"10.1590/S1413-35552009000600008","DOIUrl":null,"url":null,"abstract":"BACKGROUND: Tibial shaft fractures are the most frequent among long bone fractures. They are described in the literature according to the device and method of treatment, with recommendations that range from full weight bearing to non-weight bearing restrictions. There are studies comparing osteosynthesis devices and surgical aspects, but no references were found on how or when to allow weight bearing on the affected limb in the standing position. OBJECTIVES: The present study learned from Brazilian orthopedists which methods of osteosynthesis they use to treat open tibial fractures, whether they refer patients to physical therapy, when and why they allow partial weight bearing for both physical activity and therapy. METHODS: Two hundred and thirty-five orthopedists answered a questionnaire during the 14th Brazilian Conference of Orthopedic Trauma. Results: The results showed that, in Brazil, the most widely used osteosynthesis device is the external fixator, but earlier weight bearing while standing occurs when intramedullary nails are used. Most orthopedists refer patients to physical therapy and allow partial weight bearing in the standing position according to the material used for synthesis. CONCLUSIONS: It was concluded that there is a preference for external fixation, that most orthopedists refer patients to physical therapy and that the synthesis material influences restrictions on partial weight bearing.","PeriodicalId":21195,"journal":{"name":"Revista Brasileira De Fisioterapia","volume":"12 1","pages":"514-520"},"PeriodicalIF":0.0000,"publicationDate":"2009-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A visão do ortopedista brasileiro sobre a descarga parcial de peso em ortostase nas fraturas expostas da diáfise da tíbia após osteossíntese\",\"authors\":\"Valéria R. G. Sella, P. Machado, Hélio Jorge Alvachian Fernandes, William R. Limonge, F. B. D. Reis, F. Faloppa\",\"doi\":\"10.1590/S1413-35552009000600008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"BACKGROUND: Tibial shaft fractures are the most frequent among long bone fractures. They are described in the literature according to the device and method of treatment, with recommendations that range from full weight bearing to non-weight bearing restrictions. There are studies comparing osteosynthesis devices and surgical aspects, but no references were found on how or when to allow weight bearing on the affected limb in the standing position. OBJECTIVES: The present study learned from Brazilian orthopedists which methods of osteosynthesis they use to treat open tibial fractures, whether they refer patients to physical therapy, when and why they allow partial weight bearing for both physical activity and therapy. METHODS: Two hundred and thirty-five orthopedists answered a questionnaire during the 14th Brazilian Conference of Orthopedic Trauma. Results: The results showed that, in Brazil, the most widely used osteosynthesis device is the external fixator, but earlier weight bearing while standing occurs when intramedullary nails are used. Most orthopedists refer patients to physical therapy and allow partial weight bearing in the standing position according to the material used for synthesis. CONCLUSIONS: It was concluded that there is a preference for external fixation, that most orthopedists refer patients to physical therapy and that the synthesis material influences restrictions on partial weight bearing.\",\"PeriodicalId\":21195,\"journal\":{\"name\":\"Revista Brasileira De Fisioterapia\",\"volume\":\"12 1\",\"pages\":\"514-520\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2009-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Brasileira De Fisioterapia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/S1413-35552009000600008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Brasileira De Fisioterapia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S1413-35552009000600008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A visão do ortopedista brasileiro sobre a descarga parcial de peso em ortostase nas fraturas expostas da diáfise da tíbia após osteossíntese
BACKGROUND: Tibial shaft fractures are the most frequent among long bone fractures. They are described in the literature according to the device and method of treatment, with recommendations that range from full weight bearing to non-weight bearing restrictions. There are studies comparing osteosynthesis devices and surgical aspects, but no references were found on how or when to allow weight bearing on the affected limb in the standing position. OBJECTIVES: The present study learned from Brazilian orthopedists which methods of osteosynthesis they use to treat open tibial fractures, whether they refer patients to physical therapy, when and why they allow partial weight bearing for both physical activity and therapy. METHODS: Two hundred and thirty-five orthopedists answered a questionnaire during the 14th Brazilian Conference of Orthopedic Trauma. Results: The results showed that, in Brazil, the most widely used osteosynthesis device is the external fixator, but earlier weight bearing while standing occurs when intramedullary nails are used. Most orthopedists refer patients to physical therapy and allow partial weight bearing in the standing position according to the material used for synthesis. CONCLUSIONS: It was concluded that there is a preference for external fixation, that most orthopedists refer patients to physical therapy and that the synthesis material influences restrictions on partial weight bearing.