D. Korte, A. Grahovac, Andrej Jerkič, O. Vajdle, J. Anojčić, Guzsvány, B. Budic, M. Franko
{"title":"热透镜光谱法测定个人护理产品中离子和痕量胶体银的形态","authors":"D. Korte, A. Grahovac, Andrej Jerkič, O. Vajdle, J. Anojčić, Guzsvány, B. Budic, M. Franko","doi":"10.4172/2153-2435.1000573","DOIUrl":null,"url":null,"abstract":"The collinear dual beam thermal lens spectrometric (TLS) detection in batch mode (BM), as well as combined with the flow injection analysis (FIA), was applied to determine the colloidal silver in personal care products available in the public pharmacies and declared by producers to contain nanosilver at the level of 5-30 μg ml-1. It was found, that the examined samples contain mainly ionic silver (99% or more), whereas the colloidal form of silver is at the level of less than 1 μg ml-1. The TLS methods were confirmed to be fast, precise, highly accurate and highly sensitive with limits of quantitation of 0.30 ng ml-1 and 1.50 ng ml-1 and relative standard deviations not higher than 1.2% and 6.0% for BM- and FIA-TLS configuration, respectively. The developed TLS methods have nearly 60 times lower LOQ values concerning the colloidal silver determination than the classical spectrophotometric method. To verify the obtained results of the real sample analysis the total amount of ionic silver was determined by the use of ICP-OES technique.","PeriodicalId":19833,"journal":{"name":"Pharmaceutica Analytica Acta","volume":"4 1","pages":"1-10"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Speciation and Determination of Ionic and Trace-Level Colloidal Silver in Selected Personal Care Products by Thermal Lens Spectrometry\",\"authors\":\"D. Korte, A. Grahovac, Andrej Jerkič, O. Vajdle, J. Anojčić, Guzsvány, B. Budic, M. Franko\",\"doi\":\"10.4172/2153-2435.1000573\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The collinear dual beam thermal lens spectrometric (TLS) detection in batch mode (BM), as well as combined with the flow injection analysis (FIA), was applied to determine the colloidal silver in personal care products available in the public pharmacies and declared by producers to contain nanosilver at the level of 5-30 μg ml-1. It was found, that the examined samples contain mainly ionic silver (99% or more), whereas the colloidal form of silver is at the level of less than 1 μg ml-1. The TLS methods were confirmed to be fast, precise, highly accurate and highly sensitive with limits of quantitation of 0.30 ng ml-1 and 1.50 ng ml-1 and relative standard deviations not higher than 1.2% and 6.0% for BM- and FIA-TLS configuration, respectively. The developed TLS methods have nearly 60 times lower LOQ values concerning the colloidal silver determination than the classical spectrophotometric method. To verify the obtained results of the real sample analysis the total amount of ionic silver was determined by the use of ICP-OES technique.\",\"PeriodicalId\":19833,\"journal\":{\"name\":\"Pharmaceutica Analytica Acta\",\"volume\":\"4 1\",\"pages\":\"1-10\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmaceutica Analytica Acta\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/2153-2435.1000573\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutica Analytica Acta","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2153-2435.1000573","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
摘要
采用共线双光束热透镜光谱法(TLS)批量检测,并结合流动注射分析法(FIA),对公共药店销售的个人护理用品中纳米银的含量进行了检测,检测的纳米银含量为5 ~ 30 μg ml-1。结果发现,检测样品中离子银的含量主要在99%以上,而胶体银的含量低于1 μg ml-1。验证了TLS方法快速、精确、高准确度和高灵敏度,BM-和FIA-TLS配置的定量限分别为0.30 ng ml-1和1.50 ng ml-1,相对标准偏差分别不高于1.2%和6.0%。与传统的分光光度法相比,该方法测定胶体银的定量限降低了近60倍。为了验证实际样品分析的结果,用ICP-OES技术测定了离子银的总量。
Speciation and Determination of Ionic and Trace-Level Colloidal Silver in Selected Personal Care Products by Thermal Lens Spectrometry
The collinear dual beam thermal lens spectrometric (TLS) detection in batch mode (BM), as well as combined with the flow injection analysis (FIA), was applied to determine the colloidal silver in personal care products available in the public pharmacies and declared by producers to contain nanosilver at the level of 5-30 μg ml-1. It was found, that the examined samples contain mainly ionic silver (99% or more), whereas the colloidal form of silver is at the level of less than 1 μg ml-1. The TLS methods were confirmed to be fast, precise, highly accurate and highly sensitive with limits of quantitation of 0.30 ng ml-1 and 1.50 ng ml-1 and relative standard deviations not higher than 1.2% and 6.0% for BM- and FIA-TLS configuration, respectively. The developed TLS methods have nearly 60 times lower LOQ values concerning the colloidal silver determination than the classical spectrophotometric method. To verify the obtained results of the real sample analysis the total amount of ionic silver was determined by the use of ICP-OES technique.