{"title":"渗滤液对白蚁丘土岩土力学和地球化学性质的影响","authors":"A. Adekunle, F. Nkeshita, Adetayo Akinsanya","doi":"10.37023/ee.8.1-2.4","DOIUrl":null,"url":null,"abstract":"This\nstudy investigated the influence of leachate prepared from Telfairia\noccidentalis on the geotechnical and geochemical properties of termite mound\nsoil obtained from the premises of the federal university of agriculture,\nAbeokuta, south-western Nigeria. The termite mound soil samples were collected\nfrom three different locations and each sample collected was contaminated by\nmixing with leachates in percentage increments of 0% 10%, 15% and 20% of dry\nweight of the air-dried soil. The soil samples were subjected to Atterberg\nlimits and hydraulic conductivity tests for geotechnical observation and X-ray\nfluorescence tests for geochemical tests. The range of values for the\ngeotechnical analyses were obtained as; plastic limit (9.1% – 14.2%), liquid\nlimit (28.6 % – 61%), plasticity index ((18.2% – 49.5%) and hydraulic\nconductivity (1.85 – 4.1 x 10-8) cm/sec) with a resultant reduction\nin the plastic limit, liquid limit and plasticity index values but an increase\nin the hydraulic conductivity of the samples as the leachate concentration\nincreased. The results from X-ray fluorescence analyses after 20% leachate\ncontamination showed that the major elemental chemical composition for the\nthree samples were comprised of SiO2 (56.25 – 56.5%), Al2O3\n(28.42 – 28.50%), Fe2O3 (4.46 – 6.5%), TiO2\n(1.08 – 1.23%), CaO (1.45 – 1.60%), P2O5 (0 – 0.04%), K2O\n(0.9 – 6.1%) and MnO (0.02 – 4.7%). There was a marginal alteration of the\nindices with the values inferring the presence of a minimum composition of\nfeldspar and a major composition of quartz-rich minerals and thus lending more\ncredence to the presence of silicates as shown from the X-ray fluorescence\nresults. It also infers that the termite mounds are predominantly made from\nsand materials. The termite soil samples obtained from the aforementioned\nlocations may not be suitable for engineering works unless stabilization\nprocedure is adopted.","PeriodicalId":50518,"journal":{"name":"Environmental & Engineering Geoscience","volume":"115 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Influence of\\nleachates on geotehnical and geochemical properties of termite mound soils\",\"authors\":\"A. Adekunle, F. Nkeshita, Adetayo Akinsanya\",\"doi\":\"10.37023/ee.8.1-2.4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This\\nstudy investigated the influence of leachate prepared from Telfairia\\noccidentalis on the geotechnical and geochemical properties of termite mound\\nsoil obtained from the premises of the federal university of agriculture,\\nAbeokuta, south-western Nigeria. The termite mound soil samples were collected\\nfrom three different locations and each sample collected was contaminated by\\nmixing with leachates in percentage increments of 0% 10%, 15% and 20% of dry\\nweight of the air-dried soil. The soil samples were subjected to Atterberg\\nlimits and hydraulic conductivity tests for geotechnical observation and X-ray\\nfluorescence tests for geochemical tests. The range of values for the\\ngeotechnical analyses were obtained as; plastic limit (9.1% – 14.2%), liquid\\nlimit (28.6 % – 61%), plasticity index ((18.2% – 49.5%) and hydraulic\\nconductivity (1.85 – 4.1 x 10-8) cm/sec) with a resultant reduction\\nin the plastic limit, liquid limit and plasticity index values but an increase\\nin the hydraulic conductivity of the samples as the leachate concentration\\nincreased. The results from X-ray fluorescence analyses after 20% leachate\\ncontamination showed that the major elemental chemical composition for the\\nthree samples were comprised of SiO2 (56.25 – 56.5%), Al2O3\\n(28.42 – 28.50%), Fe2O3 (4.46 – 6.5%), TiO2\\n(1.08 – 1.23%), CaO (1.45 – 1.60%), P2O5 (0 – 0.04%), K2O\\n(0.9 – 6.1%) and MnO (0.02 – 4.7%). There was a marginal alteration of the\\nindices with the values inferring the presence of a minimum composition of\\nfeldspar and a major composition of quartz-rich minerals and thus lending more\\ncredence to the presence of silicates as shown from the X-ray fluorescence\\nresults. It also infers that the termite mounds are predominantly made from\\nsand materials. The termite soil samples obtained from the aforementioned\\nlocations may not be suitable for engineering works unless stabilization\\nprocedure is adopted.\",\"PeriodicalId\":50518,\"journal\":{\"name\":\"Environmental & Engineering Geoscience\",\"volume\":\"115 1\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2021-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Environmental & Engineering Geoscience\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://doi.org/10.37023/ee.8.1-2.4\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ENVIRONMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Environmental & Engineering Geoscience","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.37023/ee.8.1-2.4","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 1

摘要

本研究研究了从尼日利亚西南部阿贝奥库塔的联邦农业大学提取的西方白蚁渗滤液对白蚁土壤土岩土力学和地球化学性质的影响。在三个不同地点采集白蚁丘土壤样本,每个样本分别以风干土壤干重的0%、10%、15%和20%的百分比添加渗滤液污染。对土壤样品进行了阿特伯格极限和水力导电性试验,用于岩土工程观察,对地球化学试验进行了x射线荧光试验。岩土分析的取值范围为:塑性极限(9.1% - 14.2%)、液体极限(28.6% - 61%)、塑性指数(18.2% - 49.5%)和水力导电性(1.85 - 4.1 × 10-8) cm/sec)随着渗滤液浓度的增加,塑性极限、液体极限和塑性指标值降低,但水力导电性增加。浸出液污染20%后的x射线荧光分析结果表明,3个样品的主要元素化学组成为SiO2(56.25 ~ 56.5%)、Al2O3(28.42 ~ 28.50%)、Fe2O3(4.46 ~ 6.5%)、TiO2(1.08 ~ 1.23%)、CaO(1.45 ~ 1.60%)、P2O5(0 ~ 0.04%)、K2O(0.9 ~ 6.1%)和MnO(0.02 ~ 4.7%)。这些指数有轻微的变化,其值推断出存在最小的长石成分和主要的富含石英的矿物成分,因此从x射线荧光结果中可以看出,更多的证据表明存在硅酸盐。这也可以推断白蚁丘主要是由沙子构成的。除非采取稳定措施,否则从上述地点获得的白蚁土样品可能不适合用于工程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of leachates on geotehnical and geochemical properties of termite mound soils
This study investigated the influence of leachate prepared from Telfairia occidentalis on the geotechnical and geochemical properties of termite mound soil obtained from the premises of the federal university of agriculture, Abeokuta, south-western Nigeria. The termite mound soil samples were collected from three different locations and each sample collected was contaminated by mixing with leachates in percentage increments of 0% 10%, 15% and 20% of dry weight of the air-dried soil. The soil samples were subjected to Atterberg limits and hydraulic conductivity tests for geotechnical observation and X-ray fluorescence tests for geochemical tests. The range of values for the geotechnical analyses were obtained as; plastic limit (9.1% – 14.2%), liquid limit (28.6 % – 61%), plasticity index ((18.2% – 49.5%) and hydraulic conductivity (1.85 – 4.1 x 10-8) cm/sec) with a resultant reduction in the plastic limit, liquid limit and plasticity index values but an increase in the hydraulic conductivity of the samples as the leachate concentration increased. The results from X-ray fluorescence analyses after 20% leachate contamination showed that the major elemental chemical composition for the three samples were comprised of SiO2 (56.25 – 56.5%), Al2O3 (28.42 – 28.50%), Fe2O3 (4.46 – 6.5%), TiO2 (1.08 – 1.23%), CaO (1.45 – 1.60%), P2O5 (0 – 0.04%), K2O (0.9 – 6.1%) and MnO (0.02 – 4.7%). There was a marginal alteration of the indices with the values inferring the presence of a minimum composition of feldspar and a major composition of quartz-rich minerals and thus lending more credence to the presence of silicates as shown from the X-ray fluorescence results. It also infers that the termite mounds are predominantly made from sand materials. The termite soil samples obtained from the aforementioned locations may not be suitable for engineering works unless stabilization procedure is adopted.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Environmental & Engineering Geoscience
Environmental & Engineering Geoscience 地学-地球科学综合
CiteScore
2.10
自引率
0.00%
发文量
25
审稿时长
>12 weeks
期刊介绍: The Environmental & Engineering Geoscience Journal publishes peer-reviewed manuscripts that address issues relating to the interaction of people with hydrologic and geologic systems. Theoretical and applied contributions are appropriate, and the primary criteria for acceptance are scientific and technical merit.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信