{"title":"EMC实验室用射频电路换向器","authors":"L. Nowosielski, Michał Nowosielski","doi":"10.1109/PIERS-FALL.2017.8293178","DOIUrl":null,"url":null,"abstract":"Disadvantages and advantages of classical solutions for RF circuits commutator used in EMC laboratories equipped with anechoic chambers were presented in the article. An innovative solution of RF circuits commutator, which is dedicated for use in anechoic chambers was proposed. It is characterised with no disadvantages typical for classical solutions accessible on the market (e.g., OSP-130 commutator) resulting from placing executing (RF switches) as well as control circuits for them in one enclosure. There, in the article, the block diagram of the solution proposed was presented. Also, the results of the anechoic chamber shielding efficiency measurements were shown in the article for the location where coaxial cables penetrations are installed and connected to particular outputs of measurement sensors using the proposed solution of the RF circuits commutator. The results of comparative analysis were shown, too, for shielding efficiency of the anechoic chamber using the proposed solution as well as classical solutions of RF commutators.","PeriodicalId":39469,"journal":{"name":"Advances in Engineering Education","volume":"30 1","pages":"438-443"},"PeriodicalIF":0.0000,"publicationDate":"2017-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"RF circuits commutator for EMC laboratories\",\"authors\":\"L. Nowosielski, Michał Nowosielski\",\"doi\":\"10.1109/PIERS-FALL.2017.8293178\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Disadvantages and advantages of classical solutions for RF circuits commutator used in EMC laboratories equipped with anechoic chambers were presented in the article. An innovative solution of RF circuits commutator, which is dedicated for use in anechoic chambers was proposed. It is characterised with no disadvantages typical for classical solutions accessible on the market (e.g., OSP-130 commutator) resulting from placing executing (RF switches) as well as control circuits for them in one enclosure. There, in the article, the block diagram of the solution proposed was presented. Also, the results of the anechoic chamber shielding efficiency measurements were shown in the article for the location where coaxial cables penetrations are installed and connected to particular outputs of measurement sensors using the proposed solution of the RF circuits commutator. The results of comparative analysis were shown, too, for shielding efficiency of the anechoic chamber using the proposed solution as well as classical solutions of RF commutators.\",\"PeriodicalId\":39469,\"journal\":{\"name\":\"Advances in Engineering Education\",\"volume\":\"30 1\",\"pages\":\"438-443\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Advances in Engineering Education\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PIERS-FALL.2017.8293178\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Social Sciences\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advances in Engineering Education","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PIERS-FALL.2017.8293178","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Social Sciences","Score":null,"Total":0}
Disadvantages and advantages of classical solutions for RF circuits commutator used in EMC laboratories equipped with anechoic chambers were presented in the article. An innovative solution of RF circuits commutator, which is dedicated for use in anechoic chambers was proposed. It is characterised with no disadvantages typical for classical solutions accessible on the market (e.g., OSP-130 commutator) resulting from placing executing (RF switches) as well as control circuits for them in one enclosure. There, in the article, the block diagram of the solution proposed was presented. Also, the results of the anechoic chamber shielding efficiency measurements were shown in the article for the location where coaxial cables penetrations are installed and connected to particular outputs of measurement sensors using the proposed solution of the RF circuits commutator. The results of comparative analysis were shown, too, for shielding efficiency of the anechoic chamber using the proposed solution as well as classical solutions of RF commutators.
期刊介绍:
The journal publishes articles on a wide variety of topics related to documented advances in engineering education practice. Topics may include but are not limited to innovations in course and curriculum design, teaching, and assessment both within and outside of the classroom that have led to improved student learning.