{"title":"用于生物遥测应用的锯齿形CPW馈电超宽带微带贴片天线","authors":"Md. Abdul Muktadir, Md Siddat Bin Nesar, Nishako Chakma, Akash Biswas, Piyas Chowdhury, Md. Azad Hossain","doi":"10.1109/ICISET.2018.8745650","DOIUrl":null,"url":null,"abstract":"A novel and simple sawtooth shaped Ultra-Wide band (UWB) antenna design with coplanar waveguide feeding for biotelemetry applications have been suggested in this research. A unique model & noteworthy enactment of the proposed antenna validates its robustness among the other antenna of similar types. This antenna covers almost 83.7% of the UWB in between 3.1 to 10.6 GHz, having an impressive return loss below 13 dB throughout the whole range. There are four resonating frequencies within the range with a maximum return loss of 26.769 dB. Obtained maximum directivity and gain for the projected antenna are 7.635 dBi and 7.641 dBi respectively. The optimized dimension of the antenna with a simple structure of sawtooth shape is 49 mm ⨯ 42.5 mm ⨯ 1.64 mm which can be easily integrated with handheld devices for UWB applications. Several calculations and performance analysis have been done using Advanced Design System (ADS) to make the antenna more invigorated for practical use.","PeriodicalId":6608,"journal":{"name":"2018 International Conference on Innovations in Science, Engineering and Technology (ICISET)","volume":"1 1","pages":"317-321"},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A Sawtooth Shaped CPW Fed UWB Microstrip Patch Antenna for Biotelemetry Applications\",\"authors\":\"Md. Abdul Muktadir, Md Siddat Bin Nesar, Nishako Chakma, Akash Biswas, Piyas Chowdhury, Md. Azad Hossain\",\"doi\":\"10.1109/ICISET.2018.8745650\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A novel and simple sawtooth shaped Ultra-Wide band (UWB) antenna design with coplanar waveguide feeding for biotelemetry applications have been suggested in this research. A unique model & noteworthy enactment of the proposed antenna validates its robustness among the other antenna of similar types. This antenna covers almost 83.7% of the UWB in between 3.1 to 10.6 GHz, having an impressive return loss below 13 dB throughout the whole range. There are four resonating frequencies within the range with a maximum return loss of 26.769 dB. Obtained maximum directivity and gain for the projected antenna are 7.635 dBi and 7.641 dBi respectively. The optimized dimension of the antenna with a simple structure of sawtooth shape is 49 mm ⨯ 42.5 mm ⨯ 1.64 mm which can be easily integrated with handheld devices for UWB applications. Several calculations and performance analysis have been done using Advanced Design System (ADS) to make the antenna more invigorated for practical use.\",\"PeriodicalId\":6608,\"journal\":{\"name\":\"2018 International Conference on Innovations in Science, Engineering and Technology (ICISET)\",\"volume\":\"1 1\",\"pages\":\"317-321\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 International Conference on Innovations in Science, Engineering and Technology (ICISET)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICISET.2018.8745650\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 International Conference on Innovations in Science, Engineering and Technology (ICISET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICISET.2018.8745650","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

本研究提出了一种新型且简单的共面波导馈电锯齿形超宽带天线设计,用于生物遥测应用。该天线的独特模型和值得注意的设定验证了其在其他类似类型天线中的鲁棒性。该天线覆盖了3.1至10.6 GHz之间近83.7%的超宽带,在整个范围内具有低于13 dB的令人印象深刻的回波损耗。该范围内有4个谐振频率,最大回波损耗为26.769 dB。得到投影天线的最大指向性和增益分别为7.635 dBi和7.641 dBi。优化后的天线尺寸为49毫米,结构简单,呈锯齿状,可方便地与手持设备集成,用于超宽带应用。利用先进设计系统(ADS)对该天线进行了多次计算和性能分析,使其在实际应用中更具活力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Sawtooth Shaped CPW Fed UWB Microstrip Patch Antenna for Biotelemetry Applications
A novel and simple sawtooth shaped Ultra-Wide band (UWB) antenna design with coplanar waveguide feeding for biotelemetry applications have been suggested in this research. A unique model & noteworthy enactment of the proposed antenna validates its robustness among the other antenna of similar types. This antenna covers almost 83.7% of the UWB in between 3.1 to 10.6 GHz, having an impressive return loss below 13 dB throughout the whole range. There are four resonating frequencies within the range with a maximum return loss of 26.769 dB. Obtained maximum directivity and gain for the projected antenna are 7.635 dBi and 7.641 dBi respectively. The optimized dimension of the antenna with a simple structure of sawtooth shape is 49 mm ⨯ 42.5 mm ⨯ 1.64 mm which can be easily integrated with handheld devices for UWB applications. Several calculations and performance analysis have been done using Advanced Design System (ADS) to make the antenna more invigorated for practical use.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信