中性电解水对单位水系细菌增殖的抑制作用

S. Mishima, J. Sonobe, Katsu Takahashi, M. Nagao, S. Ichiyama, K. Bessho
{"title":"中性电解水对单位水系细菌增殖的抑制作用","authors":"S. Mishima, J. Sonobe, Katsu Takahashi, M. Nagao, S. Ichiyama, K. Bessho","doi":"10.4172/2247-2452.1000911","DOIUrl":null,"url":null,"abstract":"Background: Microbial contamination in dental unit waterlines (DUWLs) has recently become an important issue in the field of dental infection control. Using neutral electrolytic water as a new disinfecting method has attracted considerable attention. However, long term data about the effect of using neutral electrolytic water in clinical settings are scarce. This is the first study to evaluate the long term effectiveness of inhibition of bacterial proliferation using the purification system to supply neutral electrolytic water to refine the waterworks in DUWLs. Methods: Before the study, we investigated the actual levels of bacterial contamination in DUWLs. Then we did thorough cleaning of DUWLs and water samples were collected 6 dental units. Three dental units assigned as Group A had purification systems that used neutral electrolytic water, and the other 3 units were the Control group. Water samples were collected from the gargle water, high-speed handpieces and the three-way syringe. We utilized the equipment in Group A, and both groups were maintained for daily clinic work for 14 months. We counted the bacterial colony forming units (cfu) for each sample and identified the pathogenic bacterial species. Results: 3 and 14 months later, no microbes were detected during the study period in Group A whereas numbers of cfu which grew from the Control group increased and glucose non-fermenting gram-negative rod of possible pathogenic organisms to human were identified in the control groups. Conclusions: The water purification system using neutral electrolytic water was effective to control the proliferation of bacteria and could maintain a hygienic environment in DUWLs.","PeriodicalId":19556,"journal":{"name":"Oral health and dental management","volume":"1 1","pages":"237-240"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Effect of Inhibition of Bacterial Proliferation by Neutral Electrolytic Water inDental Unit Waterlines\",\"authors\":\"S. Mishima, J. Sonobe, Katsu Takahashi, M. Nagao, S. Ichiyama, K. Bessho\",\"doi\":\"10.4172/2247-2452.1000911\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Microbial contamination in dental unit waterlines (DUWLs) has recently become an important issue in the field of dental infection control. Using neutral electrolytic water as a new disinfecting method has attracted considerable attention. However, long term data about the effect of using neutral electrolytic water in clinical settings are scarce. This is the first study to evaluate the long term effectiveness of inhibition of bacterial proliferation using the purification system to supply neutral electrolytic water to refine the waterworks in DUWLs. Methods: Before the study, we investigated the actual levels of bacterial contamination in DUWLs. Then we did thorough cleaning of DUWLs and water samples were collected 6 dental units. Three dental units assigned as Group A had purification systems that used neutral electrolytic water, and the other 3 units were the Control group. Water samples were collected from the gargle water, high-speed handpieces and the three-way syringe. We utilized the equipment in Group A, and both groups were maintained for daily clinic work for 14 months. We counted the bacterial colony forming units (cfu) for each sample and identified the pathogenic bacterial species. Results: 3 and 14 months later, no microbes were detected during the study period in Group A whereas numbers of cfu which grew from the Control group increased and glucose non-fermenting gram-negative rod of possible pathogenic organisms to human were identified in the control groups. Conclusions: The water purification system using neutral electrolytic water was effective to control the proliferation of bacteria and could maintain a hygienic environment in DUWLs.\",\"PeriodicalId\":19556,\"journal\":{\"name\":\"Oral health and dental management\",\"volume\":\"1 1\",\"pages\":\"237-240\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-08-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oral health and dental management\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/2247-2452.1000911\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral health and dental management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2247-2452.1000911","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

背景:口腔单元水线微生物污染已成为口腔感染控制领域的一个重要问题。中性电解水作为一种新的消毒方法已引起人们的广泛关注。然而,关于在临床环境中使用中性电解水的效果的长期数据很少。这是第一个评估使用净化系统提供中性电解水来净化duwl自来水厂的细菌增殖抑制长期有效性的研究。方法:在研究之前,我们调查了duwl中细菌污染的实际水平。然后我们对duwl进行了彻底的清洁,并采集了6个牙单元的水样。3个牙科单位被指定为A组,其净化系统使用中性电解水,其他3个单位为对照组。从含漱水、高速手机和三向注射器中采集水样。A组使用该设备,两组均维持日常临床工作14个月。我们统计了每个样本的细菌菌落形成单位(cfu),并鉴定了致病菌种类。结果:3个月和14个月后,A组在研究期间未检出微生物,而对照组的cfu数量增加,对照组检测到可能致病性生物的葡萄糖非发酵革兰氏阴性棒。结论:中性电解水净化系统能有效控制细菌的繁殖,维持duwl的卫生环境。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Inhibition of Bacterial Proliferation by Neutral Electrolytic Water inDental Unit Waterlines
Background: Microbial contamination in dental unit waterlines (DUWLs) has recently become an important issue in the field of dental infection control. Using neutral electrolytic water as a new disinfecting method has attracted considerable attention. However, long term data about the effect of using neutral electrolytic water in clinical settings are scarce. This is the first study to evaluate the long term effectiveness of inhibition of bacterial proliferation using the purification system to supply neutral electrolytic water to refine the waterworks in DUWLs. Methods: Before the study, we investigated the actual levels of bacterial contamination in DUWLs. Then we did thorough cleaning of DUWLs and water samples were collected 6 dental units. Three dental units assigned as Group A had purification systems that used neutral electrolytic water, and the other 3 units were the Control group. Water samples were collected from the gargle water, high-speed handpieces and the three-way syringe. We utilized the equipment in Group A, and both groups were maintained for daily clinic work for 14 months. We counted the bacterial colony forming units (cfu) for each sample and identified the pathogenic bacterial species. Results: 3 and 14 months later, no microbes were detected during the study period in Group A whereas numbers of cfu which grew from the Control group increased and glucose non-fermenting gram-negative rod of possible pathogenic organisms to human were identified in the control groups. Conclusions: The water purification system using neutral electrolytic water was effective to control the proliferation of bacteria and could maintain a hygienic environment in DUWLs.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信