一种35分钟内使用免疫pcr的高灵敏度护理点Covid-19血清学检测方法

Pengfei Zhang, Liben Chen, Jiumei Hu, Alexander Y. Trick, Fan-En Chen, K. Hsieh, Yang Zhao, Tza-Huei Wang
{"title":"一种35分钟内使用免疫pcr的高灵敏度护理点Covid-19血清学检测方法","authors":"Pengfei Zhang, Liben Chen, Jiumei Hu, Alexander Y. Trick, Fan-En Chen, K. Hsieh, Yang Zhao, Tza-Huei Wang","doi":"10.1109/Transducers50396.2021.9495696","DOIUrl":null,"url":null,"abstract":"Serological tests play important roles in the fight against the Coronavirus Disease 2019 (COVID-19). The most commonly used methods, enzyme-linked immunosorbent assays (ELISA), provide reliable and sensitive antibody measurement though they require bulky laboratory infrastructure as well as lengthy turnaround time. Conversely, lateral flow immunoassays (LFIA) are suitable for rapid point-of-care tests but with limited sensitivity. To combine the best attributes of ELISA and LFIA, we developed a novel streamlined immuno-PCR assay and applied it to a portable magnetofluidic instrument for point-of-care serological tests. In testing 107 clinical samples, our point-of-care serological test showed 98.3% (58/59) specificity and 93.8% (45/48) agreement with benchtop immunoassays. Moreover, 100% agreement was achieved by only slightly increasing the total assay time to 45 min, demonstrating its potential as a new point-of-care serological test for COVID-19 and beyond.","PeriodicalId":6814,"journal":{"name":"2021 21st International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers)","volume":"46 1","pages":"743-746"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A Highly Sensitive Point-of-Care Covid-19 Serological Test using Immuno-PCR in 35 Mins\",\"authors\":\"Pengfei Zhang, Liben Chen, Jiumei Hu, Alexander Y. Trick, Fan-En Chen, K. Hsieh, Yang Zhao, Tza-Huei Wang\",\"doi\":\"10.1109/Transducers50396.2021.9495696\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Serological tests play important roles in the fight against the Coronavirus Disease 2019 (COVID-19). The most commonly used methods, enzyme-linked immunosorbent assays (ELISA), provide reliable and sensitive antibody measurement though they require bulky laboratory infrastructure as well as lengthy turnaround time. Conversely, lateral flow immunoassays (LFIA) are suitable for rapid point-of-care tests but with limited sensitivity. To combine the best attributes of ELISA and LFIA, we developed a novel streamlined immuno-PCR assay and applied it to a portable magnetofluidic instrument for point-of-care serological tests. In testing 107 clinical samples, our point-of-care serological test showed 98.3% (58/59) specificity and 93.8% (45/48) agreement with benchtop immunoassays. Moreover, 100% agreement was achieved by only slightly increasing the total assay time to 45 min, demonstrating its potential as a new point-of-care serological test for COVID-19 and beyond.\",\"PeriodicalId\":6814,\"journal\":{\"name\":\"2021 21st International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers)\",\"volume\":\"46 1\",\"pages\":\"743-746\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 21st International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/Transducers50396.2021.9495696\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 21st International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/Transducers50396.2021.9495696","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

血清学检测在抗击2019冠状病毒病(COVID-19)中发挥着重要作用。最常用的方法是酶联免疫吸附测定法(ELISA),它提供了可靠和敏感的抗体测量,尽管它们需要庞大的实验室基础设施以及较长的周转时间。相反,侧流免疫测定法(LFIA)适用于快速的即时检测,但灵敏度有限。为了结合ELISA和LFIA的最佳特性,我们开发了一种新型流线型免疫pcr检测方法,并将其应用于便携式磁流体仪器,用于即时血清学检测。在107份临床样本中,我们的即时血清学检测结果的特异性为98.3%(58/59),与台式免疫检测结果的一致性为93.8%(45/48)。此外,仅将总检测时间略微增加到45分钟,就实现了100%的一致性,这表明它有潜力成为COVID-19及其他疾病的新型护理点血清学检测方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Highly Sensitive Point-of-Care Covid-19 Serological Test using Immuno-PCR in 35 Mins
Serological tests play important roles in the fight against the Coronavirus Disease 2019 (COVID-19). The most commonly used methods, enzyme-linked immunosorbent assays (ELISA), provide reliable and sensitive antibody measurement though they require bulky laboratory infrastructure as well as lengthy turnaround time. Conversely, lateral flow immunoassays (LFIA) are suitable for rapid point-of-care tests but with limited sensitivity. To combine the best attributes of ELISA and LFIA, we developed a novel streamlined immuno-PCR assay and applied it to a portable magnetofluidic instrument for point-of-care serological tests. In testing 107 clinical samples, our point-of-care serological test showed 98.3% (58/59) specificity and 93.8% (45/48) agreement with benchtop immunoassays. Moreover, 100% agreement was achieved by only slightly increasing the total assay time to 45 min, demonstrating its potential as a new point-of-care serological test for COVID-19 and beyond.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信